Page 2 - User Guide
Manufacturer: ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia. Distributed by: ResMed Corp 9001 Spectrum Center Boulevard San Diego CA 92123 USA. ResMed (UK) Ltd 96 Milton Park Abingdon Oxfordshire OX14 4RY UK. See www.resmed.com for other ResMed locations worldwide. For patent...
Page 3 - Contents
Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Indications for use 1 Contraindications 1 Components of your H4i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Setting up your H4i for use . . . . . . . . . ....
Page 4 - gl; Introduction; Indications for use; Components of your H4i; Preparation
1 Introduction En gl ish Introduction The H4i ™ is designed to moisten the air delivered to your airway during Positive Airway Pressure (PAP) therapy. Indications for use The H4i is indicated for humidification of the air delivered from a ResMed compatible CPAP, bilevel and non-invasive ventilation ...
Page 5 - System setup
2 System setup 1 Align your H4i with your flow generator and push them together until they click into place. 2 Connect the power cord to the socket on the rear of your flow generator. 3 Plug the other end of the power cord into the power outlet.Place the combined unit on a firm, level surface near y...
Page 6 - Filling the water chamber; Detaching your H4i
3 Setting up your H4i for use En gl ish Filling the water chamber 1 Open the cover. 2 Remove the water chamber. 3 Fill with fresh, clean water up to or below the maximum water level mark. Note: The water chamber must be removed from the H4i before it is filled or water may enter the flow generator. ...
Page 7 - Starting and stopping treatment; Warming your H4i with the VPAP or S8 Series; Warming your H4i with the Stellar; Starting your treatment
4 4 Pull the H4i and flow generator apart. Note : Re-attach the connector plug firmly to your flow generator. Starting and stopping treatment Warming your H4i with the VPAP or S8 Series The Warm-Up feature (not available on all ResMed PAP devices) is used to pre-heat the water before starting treatm...
Page 8 - Stopping your treatment; Cleaning and maintenance; Disassembling the H4i cleanable water chamber
5 Cleaning and maintenance En gl ish ! WARNING Do not leave an excessive length of air tubing around the top of your bed. It could twist around your head or neck while you are sleeping. Stopping your treatment To stop your treatment, refer to your device user guide. Note : In order to assist the hea...
Page 9 - Cleaning your H4i; Water chamber; Daily
6 Cleaning your H4i Water chamber Daily Wash the water chamber, spill guard, tub plate and tub plate seal in warm water, using a mild detergent. Use the yellow cleaning plug to assist in the cleaning process (see steps 1 to 4). Rinse thoroughly in clean water and allow them to dry away from direct s...
Page 10 - Cover and cover seal; Docking station; Heater plate; Reassembling the H4i cleanable water chamber
7 Cleaning and maintenance En gl ish Cover and cover seal 1 Remove the cover by gently flexing one cover arm away and up from the docking station until the cover detaches completely. 2 Peel the cover seal away from the cover. 3 Inspect the cover and cover seal weekly for wear and deterioration. Repl...
Page 11 - Reassembling your H4i; Servicing
8 4 Reinsert the spill guard into the water chamber recess and push down to fit firmly into place. Reassembling your H4i Reassemble the parts when they are clean and dry. 1 Align the cover seal to the guides on the cover and press along the edges to ensure it is fitted properly. 2 Put one cover arm ...
Page 12 - Troubleshooting
9 Troubleshooting En gl ish Troubleshooting If there is a problem, try the following suggestions. If the problem cannot be solved, contact your equipment supplier or ResMed. Do not open the unit. ! WARNING Service and repair should only be performed by an authorised service agent. Problem Possible c...
Page 13 - Technical specifications; Humidifier performance
10 Technical specifications Humidifier performance The following settings have been tested at 22°C, 40% RH ambient conditions: Note : The manufacturer reserves the right to change these specifications without notice. Maximum heater plate temperature 85°C Temperature cut-out 93°C Maximum gas temperat...
Page 14 - Symbols which appear on the device; General warnings
11 General warnings En gl ish Symbols which appear on the device Caution; Read instructions before use; European Authorised Representative; Type BF Applied Part; Hot surface; Class II equipment; Do not touch; Humidifier control; Maximum water level; Manufacturer; Environmental information WEEE 2002/...
Page 15 - Limited warranty
12 Limited warranty ResMed Ltd (hereafter ’ResMed’) warrants that your ResMed product shall be free from defects in material and workmanship from the date of purchase for the period specified below. This warranty is only available to the initial consumer. It is not transferable.If the product fails ...
Page 16 - USER
H4i ™ HEATED HUMIDIFIER User Guide English Global leaders in sleep and respiratory medicine www.resmed.com 248672/1 2013-02 H4i USER EUR 1 - ENG 1 2 4 5 Filling the water chamber / Auffüllen der Befeuchterkammer / Remplissage du réservoir / Riempimento della camera dell’acqua / Llenado de la cámara ...