Page 2 - Listing Label Information/Location; Owner’s Manual; Homeowner Reference Information; NATURA L GAS; Read this manual before installing or operating this appliance.
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on fi replace: _____________________ Dealers...
Page 3 - Safety Alert Key:; • NOTICE: Used to address practices not related to personal injury.; Table of Contents; User Guide
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicate...
Page 4 - CONDITIONS, EXCLUSIONS & LIMITATION OF LIABILITY
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 4 B. Limited Lifetime Warranty Hearth & Home Technologies LIMITED WARRANTY Hearth & Home Technologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an author...
Page 6 - B. BTU Specifi cations; Models; A. Appliance Certifi cation; NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.; C. High Altitude Installations; Listing and Code Approvals
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 6 B. BTU Specifi cations MODELS: QVI-35B-S LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: Vented Gas Appliance Heater STANDARD: ANSI Z21.88b-2008/CSA 2.33b-2008 This product is listed to ANSI standards for “Vented Gas Appliance Heaters” and ...
Page 7 - Operating Instructions; A. Gas Fireplace Safety; WARNING; HOT SURFACES
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 7 2 2 Operating Instructions Figure 2.1 General Operating Parts B. Your Fireplace WARNING! DO NOT operate fi replace before read-ing and understanding operating instructions. Failure to operate fi replace according to operating instructions could ca...
Page 8 - E. Fixed Glass Assembly; G. Before Lighting Fireplace; have a
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 8 C. Clear Space WARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth. Heat may damage ...
Page 9 - H. Standing Pilot Ignition; NOT FOR USE; Final inspection by
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 9 H. Standing Pilot Ignition 1. Turn off all electric power to the appliance if ser- vice is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position. 4. Push in gas control knob slightly and turn clock- wise to OFF”. DO NOT f...
Page 10 - ISSUE
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 10 Initial Break-in Procedure • The appliance should be run three to four hours continuously on high. • Turn the appliance off and allow it to completely cool. • Remove fi xed glass assembly. See Section 14.G. • Clean fi xed glass assembly. See Sect...
Page 11 - Glass Cleaning; Tools Needed; Maintenance and Service; Tools needed; Remote Control
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 11 Glass Cleaning Frequency: Seasonally By: Homeowner Tools Needed : Protective gloves, glass cleaner, drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care. Glass is breakable. • Avoid striking, scratching or slammin...
Page 14 - A. Typical Appliance System; Getting Started; Installer Guide
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 14 A. Typical Appliance System NOTICE: Illustrations and photos refl ect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual VERTICAL TERMINATION CAP ...
Page 16 - Read all of the instructions before starting the instal-; C. Tools and Supplies Needed; Any such action may cause a fi re hazard.
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 16 B. Design and Installation Considerations Quadra-Fire gas inserts are designed for installations into solid fuel masonry or factory built fi replaces that have been installed in accordance with the National, Provin-cial, State and local building ...
Page 17 - Fireplace Size Requirements; A. Minimum Fireplace Opening; • Any smoke shelves, shields and baffl es may be removed; TOP VIEW; • The metal fl oor of the solid fuel fi rebox may be removed to
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 17 5 5 Fireplace Size Requirements A. Minimum Fireplace Opening Minimum fi replace opening requirements are shown in Figure 5.1. WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access. Due to high tempe...
Page 18 - B. Mantel and Wall Projections; • Use leveling legs to raise insert minimum 1/4 inch (6 mm)
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 18 B. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear-ances to combustibles as specifi ed. Framing or fi nishing material closer than the minimums listed must be construct-ed entirely of noncombustible materials (i.e...
Page 19 - A. Vent Termination Minimum Clearances; Termination Locations
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 19 A. Vent Termination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0*Over 6/12 to 7/12 .................................................1.25*Over 7/12 to 8/12 .....................
Page 20 - Installation Preparation; A. Inspection and Cleaning; • T h e s o l i d f u e l b u r n i n g f i r e p l a c e m a n u f a c t u r e r ’ s; F. Electrical Outlet Box
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 20 7 7 Installation Preparation Prepare the existing solid fuel masonry or factory built non-combustible fi rebox for installation. A. Inspection and Cleaning Prior to installing the gas insert: • Have the chimney and adjacent structure inspected an...
Page 21 - B. Venting Components; Installing Vent Pipe and Appliance; C. Connecting Vent Pipe; • May impair safe operation of this appliance or other; Description
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 21 B. Venting Components CAUTION! Risk of Cuts/Abrasions/Flying Debris. Wear protective gloves and safety glasses during instal-lation. Sheet metal edges are sharp. The vertical vent termination system installed on this model includes: • One 3-foot ...
Page 22 - ance; • The 3 foot section of stainless steel fl exible pipe MUST; SLIDE PLATE BRACKET
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 22 Figure 8.2 CUT AND BEND FLASHING AS NEEDED TO FIT CHIMNEY SEALANT ADHESIVE • Trim chimney top plate to minimize excess overhang or bend over fl ue tile (see Figure 8.2). • Place 3/8 inch bead of 300º F silicone on fl ue tile top. D. Placing, Secu...
Page 23 - F. Installing Adaptor and Termination Cap; Damper Flashing Kit; : Damper may have to be removed to use this kit.; N o t e; Masonry; OR
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 23 F. Installing Adaptor and Termination Cap For installation of termination cap see minimum vent heights for various pitched roofs (see Figure 8.5) . To install adaptor see Figure 8.6. Roof Pitch H (Min.) Ft.Flat to 6/12....................1.0*Over...
Page 24 - • Purge should be performed by technician certifi ed by; Gas Information; Gas Pressure; • If substituting for these components, please consult; D. High Altitude Installations
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 24 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualifi ed technician (NFI certifi ed or factory-trained) using Hearth & Home Technologies specifi ed and approved parts. B. ...
Page 25 - B. Standing Pilot Ignition System Wiring; DOES NOT; NOTICE: DO NOT wire 110 VAC to the millivolt valve! This; A. Wiring Requirements; Electrical Information
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 25 ON OFF ON/OFF SWITCH REMOTE SWITCH PIGTAIL OPTIONAL WALL SWITCH, THERMOSTAT OR REMOTE STANDING PILOT WHT RED VALVE B. Standing Pilot Ignition System Wiring • The standing pilot ignition system wiring DOES NOT require a 110 VAC supply to operate. ...
Page 26 - C. Junction Box Installation; Optional Accessories
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 26 C. Junction Box Installation Figure 10.3 Junction box installation JUNCTION BOX SIDEWALL FEED PLUG THROUGH HOLE INSERT STRAIN RELIEF AROUND CORD IN THIS END FROM OUTSIDE OF UNIT SCREW PROVIDED Optional Accessories Connecting the electrical juncti...
Page 28 - A. Mantel and Wall Projections; Finishing
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 28 A. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear-ances to combustibles as specifi ed. Framing or fi nishing material closer than the minimums listed must be construct-ed entirely of noncombustible materials (i.e...
Page 29 - • Embers CANNOT be placed directly over ports. Care; Appliance Setup
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 29 A. Remove Glass Assembly See Section 12.G. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underne...
Page 30 - Logs are fragile! Carefully remove the logs from the packaging.
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 30 F. Install the Log Assembly Log Set Assembly: LOGS-CFXGB For Models: FB-GRAND-S, QVI35FB-S This model uses locating tabs to positively locate the logs with respect to the grate assembly. LOG NUMBER 1 (SRV768-701): Place log #1 onto the grate. Pus...
Page 33 - H. Air Shutter Setting; G. Fixed Glass Assembly; Removing Fixed Glass Assembly; Air Shutter Settings; NG
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 33 H. Air Shutter Setting Air shutter settings should be adjusted by a qualifi ed in-staller at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shut-ter for longer vertical runs. NOTICE: If s...
Page 34 - A. Standing Pilot Ignition System; Troubleshooting; Symptom
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 34 A. Standing Pilot Ignition System 13 13 Troubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a q...
Page 36 - Reference Materials; A. Appliance Dimension Diagram; MODEL DIMENSIONS
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 36 D F E H G ELECTRICAL ACCESS (IF EQUIPPED) GAS INLET C A B 2-1/16 in. 52 mm 1-9/16 in. 40 mm 3-9/16 in. 91 mm 1-1/16 in. 28 mm 2-1/2 in. 64 mm 4 in. 102 mm 13-3/4 in. 350 mm 3-1/8 in. 80 mm 6-5/8 in.169 mm Two ø 2-13/16 in. 71 mm 9-9/16 in. 142 mm...
Page 37 - B. Vent Kits Components
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 37 B. Vent Kits Components Direct Vent Flex Liner Kits (see Figure 15.2) LINK-DV-30B or (LINK-DV-30): Masonry 3 inch fl ex liner kit. Expands to 30 feet. Includes: two liners, termination cap, fl ashing, and link adapter. LINK-DV4-30B or (LINK-DV4-3...
Page 38 - Service Parts Diagram; Part number list on following page.; Log Set Assembly
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 38 C. Service Parts QVI-35FB-S Beginning Manufacturing Date: Dec. 2008 Ending Manufacturing Date: ______ Service Parts Diagram Part number list on following page. Log Set Assembly 5 6 7 8 9 10 11 12 4 3 1 2
Page 39 - ITEM
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 39 C. Service Parts List QVI-35FB-S IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorize...
Page 40 - Service Parts; Valve Assembly Diagram/ Parts List; Stocked
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 40 Service Parts QVI-35FB-S Beginning Manufacturing Date: Dec. 2008 Ending Manufacturing Date: ______ Valve Assembly Diagram/ Parts List 11 12 8 9 10 1 2 3 4 7 6 5 IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts fo...
Page 41 - D. Contact Information; For the location of your nearest Quadra-Fire dealer,; DO NOT DISCARD THIS MANUAL; NOTICE
Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 41 Quadra-Fire, a brand of Hearth & Home Technologies Inc. 7571 215 th Street West, Lakeville, MN 55044 www.quadrafi re.com D. Contact Information Please contact your Quadra-Fire dealer with any questions or concerns. For the location of your ne...