Page 2 - Listing Label Information/Location; This owner’s manual; Homeowner Reference Information; Read this manual before installing or operating this appliance.; XXXXXXXXX; Gas Type
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on replace: _____________________ Dealership purch...
Page 3 - Safety Alert Key:; Used to address practices not related to personal injury.; Table of Contents
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicates a ha...
Page 5 - CONDITIONS, EXCLUSIONS & LIMITATION OF LIABILITY
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 5 B. Limited Lifetime Warranty Warranty Period HHT Manufactured Appliances and Venting Components Covered Parts Labor Gas Wood Pellet EPA Wood Electric Venting 1 Year X X X X X X All Parts and Material Except as covered by Conditions, Exclusion, and Limit...
Page 6 - B. Limited Lifetime Warranty
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 6 gasketing, glass discoloration, rebrick, pellet logs, kaowool or other ceramic insulating materials. Rust and/or corrosion on any of the metal surfaces, cast iron components, baf es, repots, doors, or rebox area are not covered by this warranty. Noise...
Page 7 - Direct Vent Gas Heater; E. Non-Combustible Materials Speci cation; NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.; D. High Altitude Installations; If the heating value of the gas has been reduced,; Listing and Code Approvals; A. Appliance Certi cation; T h i s a p p l i a n c e m u s t b e e l e c t r i c a l l y w i r e d; National Electric Code; or the; Canadian Electric; B. Ceramic Glass Speci cations; IPI
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 7 C. BTU Speci cations MODELS: QFP44 LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: Direct Vent Gas Heater STANDARD: ANSI Z21.88-2003 • CSA2.33 This product is listed to ANSI standards for “Vented Gas Fireplace Heaters” and applicable sections of ...
Page 9 - operate replace before reading and; A. Gas Fireplace Safety; Operating Instructions; User Guide; Hot glass will cause burns.; WARNING
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 9 Decorative Doors (not shown)Section 2.E. Fixed Glass Assembly Section 2.F. Mantel Hearth (not required) Dashboard Control Section 2.G. Clear SpaceSection 2.D. Figure 2.1 General Operating Parts B. Your Fireplace WARNING! DO NOT operate replace before re...
Page 10 - place combustible objects in front of; E. Fixed Glass Assembly; Install ONLY doors or fronts; Valve Control
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 10 Clear Space 3 ft (0.91 m) in front ofappliance C. Clear Space WARNING! DO NOT place combustible objects in front of the replace or block louvers. High temperatures may start a re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects o...
Page 11 - Ignitor Battery Box; CHANGES OR MODIFICATIONS TO THIS; This equipment has been tested and found to; Canadian Equipment Requirements; Le present; FCC REQUIREMENTS; Ignitor Battery Box
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 11 Ignitor Battery Box By pulling the drawer forward, the ignitor battery box can be accessed to replace the AA battery as necessary. See Figure 2.4. Ignitor Battery Box Figure 2.4 Accessing the Ignitor Battery Box. G. Remote Operation This remote control...
Page 12 - Receptacle on back; Transmitter
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 12 Remote Receiver The remote receiver has a 3-position slide switch: OFF/REMOTE/ON (see Figure 2.5). NOTE: The remote receiver will only respond to the transmitter when the 3-position slide button on the remote receiver is in the Remote position. If the ...
Page 13 - Matching Security Codes
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 13 1. LOW - Battery power low. Replace batteries within two weeks. 2. TIMER - Indicates time remaining before system shuts off, when timer- programmed, 9 - hour maximum setting. 3. MODE - Indicates operation MODE of system. ON indicates the system is on, ...
Page 16 - H. Before Lighting Fireplace; Before operating this replace for the rst time,; have a; • Verify all shipping materials have been removed from; Timer Operation
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 16 H. Before Lighting Fireplace Before operating this replace for the rst time, have a quali ed service technician : • Verify all shipping materials have been removed from inside and/or underneath the rebox. • Review proper placement of logs, rockwool and...
Page 17 - WHAT TO DO IF YOU SMELL GAS:; result causing property damage, personal injury or loss of life
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 17 1. Turn unit off with remote.2. Turn off all electric power to the appliance if service is to be performed.3. Push in gas control knob slightly and turn clockwise to "OFF" position. FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS TO ...
Page 18 - Initial Break-in Procedure; • T h e f i r e p l a c e s h o u l d b e r u n t h r e e t o f o u r h o u r s; J. After Fireplace is Lit; ISSUE; Condensation on the glass
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 18 Initial Break-in Procedure • T h e f i r e p l a c e s h o u l d b e r u n t h r e e t o f o u r h o u r s continuously on high. • Turn the replace off and allow it to completely cool.• Remove xed glass assembly. See Section 14.A.• Clean xed glass asse...
Page 19 - Glass Cleaning; Tools Needed; CAUTION! Handle xed glass assembly with care.; Note; Maintenance and Service; The replace should be; Tools needed; Remote Control
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 19 Glass Cleaning Frequency: Seasonally By: Homeowner Tools Needed : Protective gloves, glass cleaner, drop cloth and a stable work surface. CAUTION! Handle xed glass assembly with care. Glass is breakable. • Avoid striking, scratching or slamming glass• ...
Page 22 - A. Typical Appliance System; drawn to scale. Actual product may vary from pictures in manual; Getting Started; Installer Guide; Dual venting con gurations; A R E N O T; a l l o w e d . A p p l i a n c e; MUST; be vented; EITHER; vertically; OR
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 22 Noncombustible roof flashing maintains minimum clearance around pipe(SECTION 10) Ceiling Firestopon floor of attic(SECTION 8) Vent Pipe(SECTIONS 7, 8, 10) Framing/Header (SECTION 5) Gas Line(SECTION 11) Framing Headed offin Ceiling Joists(SECTION 8) Ma...
Page 23 - Damaged parts; C. Tools and Supplies Needed; • Installation and use of any damaged appliance or vent system; Any such action may cause a re hazard.; use this appliance if any part has been under wa-
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 23 B. Design and Installation Considerations Quadra-Fire direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the out-side. No additional outside air source is r...
Page 24 - Framing and Clearances; A. Select Appliance Location; Provide adequate
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 24 5 5 Framing and Clearances A. Select Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). WARNING! Risk of Fire or Burns! Provide adequate clearance around air ope...
Page 25 - B. Construct the Appliance Chase; DO NOT; must; Model
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 25 Combustible flooring may be installed next to the front of the appliance. ALL SURFACES MUST BE FLUSHWITH THE BOTTOM OF THE UNIT. C B A Drywall 1-1/2 in. (38 mm) 0 in. 1-1/2 in. (38 mm) 0 in. D 40-7/8 in. (1038 mm) to ceiling 0 in. to level of standoffs...
Page 26 - D. Mantel and Wall Projections; Comply with all minimum clear-; Mantel Leg or; Mantels
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 26 Mantel Non-combustible Face A A = 53 in. (1346 mm) min. Non-combustible Mantel 12 in. (308 mm) maximum depth A = 66 in. (1676 mm) min. Combustible Mantel D. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear- ances to comb...
Page 27 - A. Vent Termination Minimum Clearances; Termination Locations; pack air space with insulation or other
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 27 Direct Vent Gas, Wood or Fuel Oil Termination 20 in. (508 mm) (minimum) to Perpendicular Wall (DV only) Wood, Gas or Fuel Oil Termination 20 in. min. * (508 mm) Termination Caps Same Height * If using decorative cap cover(s), this distance may need to ...
Page 29 - mix pipe, ttings or joining methods from differ-; Vent Information and Diagrams; D. Measuring Standards; • Horizontal terminations are measured to the outside; DVP Pipe
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 29 Horizontal Vertical 8-1/2 in. 8-1/2 in. 12 in. On 45° runs, 1 ft (.3 m) of diagonal is equal to 8-1/2 in. (216 mm) horizontal run and 8-1/2 in. (216 mm) vertical run. A. Approved Pipe This appliance is approved for use with Hearth & Home Technologi...
Page 30 - One Elbow
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 30 H 1 V 1 To replace the rst starter elbow with two 45° elbows, refer to Figure 7.4. All other 90° elbows can be replaced with two 45° elbows. General Rules: • SUBTRACT 3 ft. from the total H measurement for each 90° elbow installed horizontally. • SUBTR...
Page 31 - Installed
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 31 4 ft min. (1.22 m) 17 ft max. (5.18 m) 3 ft min. (.91 m) 1. Top Vent - Horizontal Termination - (continued) Figure 7.4 Two 45° Elbows replacing One 90° Elbow Figure 7.5 Three Elbows H 1 V 1 V 2 H 2 Installed Vertically V 1 H 1 V 2 H 2 3 ft (.91 m) 3 ft...
Page 33 - Three Elbows
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 33 Figure 7.9 2. Top Vent - Vertical Termination - (continued) Three Elbows 12 ft (3.66 m) min.60 ft (18.29 m) max. Maximum horizontal run is 100% of vertical, but cannot exceed 26 ft (7.92 m)
Page 34 - A. Pipe Clearances to Combustibles; Maintain air space clearance to; Vent Clearances and Framing; B. Wall Penetration Framing; Combustible Wall Penetration; • The opening must be framed on all four sides using the; Non-Combustible Wall Penetration
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 34 No combustible framing to be located within shaded area. 1-1/2 in. (13 mm)minimum toperpendicularwall. WA L L 2 x 4 or 2 x 6 header Drywall 3 in. (76 mm) 1 in. (25 mm) minimum Air space clearance to bottom and sides of horizontal pipe must be at least ...
Page 35 - C. Install the Ceiling Firestop; A ceiling restop; be used between oors and at-
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 35 C. Install the Ceiling Firestop A ceiling restop MUST be used between oors and at- tics. • Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/ oor (see Figure 8.3). • Frame the area with the same sized lumber as...
Page 36 - D. Install Attic Insulation Shield; allow loose materials or; Flat Ceiling Installation; Vaulted Ceiling Installation; Cut previously installed batt insulation to make
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 36 Bend all tabs inward 90° to maintain clearance and prevent insulation from falling inside Insert 3 screws Bend 4 tabs inward 90° to maintain clearance Laser-etchedcut lines D. Install Attic Insulation Shield WARNING! Fire Risk. DO NOT allow loose mater...
Page 37 - A. Secure and Level the Appliance; Prevent contact with:; Appliance Preparation; The bottom of the door frame at time of
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 37 A. Secure and Level the Appliance WARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation• Insulation backing or plastic• Framing and other combustible materials Block openings into the chase to prevent entry of blown-in insulation. ...
Page 38 - Install Vent Pipe; A. Assemble Vent Sections; Attach Pipe to the Firebox Assembly; Assemble Pipe Sections; WARNING! Risk of Fire or Explosion! DO NOT; Make sure that the seams are not aligned to prevent; INCORRECT
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 38 Lances 10 10 Install Vent Pipe A. Assemble Vent Sections Attach Pipe to the Firebox Assembly Note: The end of the pipe sections with the lanced tabs will face towards the appliance. Attach the rst pipe section to the starting collar: • Lanced pipe end ...
Page 39 - B. Assemble Slip Sections; Overlap pipe; When installing a vent system with an HRC
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 39 B. Assemble Slip Sections WARNING! Risk of Fire or Asphyxiation! Overlap pipe sections at least 1 1/2 in. (38 mm). Secure slip sections with two screws which must not exceed 1/2 in. (13 mm) in length. Use the pilot holes. Pipe could separate if not pro...
Page 40 - D. Disassemble Vent Sections; • Pull carefully to separate the pieces of pipe.; C. Secure the Vent Sections; • Vertical runs of pipe must be supported every 8 ft. (2.44
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 40 Figure 10.7 Securing Vertical Pipe Sections Figure 10.8 Securing Horizontal Pipe Sections D. Disassemble Vent Sections • Rotate either section (see Figure 10.9) so the seams on both pipe sections are aligned as shown in Figure 10.10. • Pull carefully t...
Page 41 - E. Install Metal Roof Flashing; • See minimum vent heights for various pitched roofs; Failure to properly caulk the roof ashing could; Caulk
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 41 E. Install Metal Roof Flashing Note: Skip to Section 10.I. if using the RF4-8. • See minimum vent heights for various pitched roofs (Figure 10.11) to determine the length of pipe to extend through the roof. • Slide the roof ashing over the pipe section...
Page 42 - F. Assemble and Install Storm Collar; • Wrap the storm collar around the exposed pipe section
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 42 F. Assemble and Install Storm Collar CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during installa-tion. Sheet metal edges are sharp. • Connect both halves of the storm collar with two screws (see Figure 1...
Page 43 - Apply Sealant
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 43 G. Install RF4-8 The RF4-8 may be used in place of the roof ashing and storm collar. Pipe must be supported within 12 in. (305 mm) of the roo ine using plumbers strapping when using the RF4-8 Flashing. Refer to Sect. 10.C. Securing Vent Sections. • Tri...
Page 44 - Heat shields may not be eld constructed.; To prevent overheating and re,; H. Install Vertical Termination Cap; Termination Cap
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 44 Important Notice: Heat shields may not be eld constructed. I. Heat Shield Requirements for Horizontal Termination WARNING! Risk of Fire! To prevent overheating and re, heat shields must extend through the entire wall thick-ness. • DO NOT remove the hea...
Page 45 - J. Install Horizontal Termination Cap; The telescoping ue section
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 45 INTERIOR Heat Shield or Extended Heat Shield Wall Shield Firestop Heat Shield 1-1/2 in. (38 mm) min. overlap SHEATHING Slip Section can be extended Inner Vent Outer Vent EXTERIOR Figure 10.20 Venting through the wall Note: When using termination caps w...
Page 46 - Gas Information; Converting to LP Gas
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 46 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home Technologies speci ed and approved parts. 11 11 Gas Information • Turn control kno...
Page 47 - • Remove #62 pilot injector using 5/32 allen wrench and; • R e m o v e s o l e n o i d f r o m t h e v a l v e b y t u r n i n g; Do not remove retaining clip from the hood.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 47 Control Knob Screw (pressure adjustment) Pin (blue-NG, red-LP) Solenoid Lock Nut Figure 11.7 Valve Components • Replace 2 screws holding pilot bracket to burner.• Pull hood keeper from pilot and lift hood off pilot assembly. See Figure 11.5. Figure 11....
Page 48 - • If substituting for these components, please consult
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 48 C. Gas Connection • Refer to Reference Section 16.A. for location of gas line access in appliance. • Gas line may be run through knockout provided on the left side only. • The gap between supply piping and gas access hole may be caulked with high tempe...
Page 49 - B. Standing Pilot Ignition System Wiring; wire 110 VAC to the millivolt valve! This; A. Wiring Requirements; WARNING! Risk of Shock or Explosion! DO NOT; C. Optional Accessories Requirements; Electrical Information
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 49 B. Standing Pilot Ignition System Wiring • The standing pilot ignition system wiring does not require a 110 VAC supply to operate. • A 110 VAC junction box MUST be installed for use with a fan or remote control. See Figure 12.2 for junction box wiring....
Page 50 - D. Electrical Service and Repair; Label all wires prior to; Replace damaged wire with; E. Junction Box Installation; OUTSIDE; INSIDE
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 50 D. Electrical Service and Repair WARNING! Risk of Shock! Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Figure 12.1 Wiring Diagram WARNI...
Page 51 - Finishing; A. Mantel and Wall Projections
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 51 Mantel Non-combustible Face A A = 53 in. (1346 mm) min. Non-combustible Mantel 12 in. (308 mm) maximum depth A = 66 in. (1676 mm) min. Combustible Mantel Figure 13.1 Minimum Vertical and Maximum Horizontal Dimensions 11 in. (279 mm) Min.to perpendicula...
Page 52 - apply combustible ma-; Template; C. Facing Template Removal; outside surface t
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 52 0 in. 0 in. 0 in. Finish wall material may be combustible - Top and Sides High Temperature Sealant (300° F/149° C min.) Non-Combustible Zone These joints may be taped and covered with joint compound. B. Facing Material • The QFP44 is shipped with non-c...
Page 53 - Appliance Setup; C. Install the Refractory; A. Remove Glass Assembly; Handle xed glass; B. Clean the Appliance; WARNING! Risk of Fire and Electric Shock!
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 53 14 14 Appliance Setup C. Install the Refractory • Remove the refractory retainer from each side of the rebox. • Put the left side refractory in place and reinstall the left side refractory retainer. Glass Latches Figure 14.1 Glass Assembly Removal Refr...
Page 54 - • Install the upper back refractory.; necessary to close up any gaps in the corners.; As you use the appliance, expansion and contraction; This appliance should be run; D. Adjust the Air Shutter; If sooting occurs, provide more air by opening
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 54 • Install the upper back refractory. Figure 14.4 Install Upper Back Refractory • Install the right side refractory. • Slide the back refractory slightly from side to side as necessary to close up any gaps in the corners. • Install the right side refrac...
Page 55 - • Remove the grate from the hearth by removing the; E. Adjust the Vertical Baf e; • Position the grate in the recess of the ember bed; • Position the cut out on the left front log over the grate
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 55 Figure 14.7 Adjust the Vertical Baf e Figure 14.8 Positioning Rear Log F. Install Logs, Ember Bed & Rockwool • Remove the grate from the hearth by removing the screws. • Position rear log over the locating tabs at the rear of the hearth pan. See Fi...
Page 56 - • Position the right front log over the grate bars, aligning; • Position the cutout on the bottom of the left log over the; • Position the right log over the locating bracket on the; • Place the end of the right middle log on the at area; • Place the end of the left middle log on the at area of
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 56 • Position the right front log over the grate bars, aligning the cut outs on the bottom of the log with the bars. See Figure 14.12 Figure 14.12 Positioning Right Front Leg • Position the cutout on the bottom of the left log over the locating bracket on...
Page 57 - H. Place Lava Rock and Vermiculite; • Cover the visible area of the metal hearth pan around; J. Install Door Fronts; • Reinstall glass by reversing steps in Section 14.A.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 57 WARNING! Risk of Explosion! Follow rockwool placement instructions. DO NOT place rockwool directly over burner ports. Replace rockwool material annually. Improperly placed rockwool interferes with proper burner operation. • Rockwool is shipped with thi...
Page 58 - A. Standing Pilot Ignition System; Troubleshooting; Symptom; After repeated triggering
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 58 A. Standing Pilot Ignition System 15 15 Troubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a quali e...
Page 60 - Reference Materials; A. Appliance Dimension Diagram; Gas
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 60 16 16 Reference Materials 49 in. 1245 mm 40 in. 1016 mm 35-1/2 in. 902 mm A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5. Figure 16.1 Appliance...
Page 61 - B. Vent Components Diagrams
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 61 B. Vent Components Diagrams Figure 16.2 DVP Vent Components Effective Height/Length DVP Pipe (see chart) Pipe inches mm DVP4 4 102 DVP6 6 152 DVP12 12 305 DVP24 24 610 DVP36 36 914 DVP48 48 1219 DVP6A 3 - 6 76 - 152 DVP12A 3 - 12 76 - 305 Effective Hei...
Page 62 - continued
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 62 B. Vent Components Diagrams ( continued ) Figure 16.3 DVP Vent Components 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (698 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (367 mm) RF12M Roof Flashing Multi-pak BEK...
Page 64 - Horizontal Termination Cap; The heat shield is designed to be
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 64 B. Vent Components Diagrams ( continued ) Figure 16.5 DVP Vent Components DVP-TRAP1 DVP-TRAP2 DVP-HPC1 DVP-HPC2 DVP-TRAP Horizontal Termination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap ...
Page 65 - Service Parts
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 65 C. Service Parts 13 14 17 18 20 16 19 15 28 31 32 29 30 26 24 22 21 27 23 25 6 3 1 7 4 2 5 Log Set Assembly Refractory Assembly 8 9 10 11 12 QFP44 Service Parts 44 in. Gas Appliance - DV Beginning Manufacturing Date: Aug 2006 Ending Manufacturing Date:...
Page 66 - Service Parts Diagram
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 66 24 23 22 12 26 19 20 16 3 4 5 10 11 9 8 6 13 7 25 14 17 15 18 21 2 1 Service Parts QFP44 Service Parts Diagram 44 in. Gas Appliance - DV Beginning Manufacturing Date: Aug 2006 Ending Manufacturing Date: Active IMPOR T ANT : THIS IS DA TED INFORMA TION....
Page 67 - D. Optional Components; Wall Thermostat - Manual
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 67 D. Optional Components Door (iron full view) DF-QFP44-IFV Door (iron operable) DF-QFP44-IOP Door (Craftsman operable, black) DF-QFP44-COP-BK Door (Craftsman operable, sienna bronz) DF-QFP44-COP-SB Wall Thermostat - Manual 812-3760 Wall Thermostat - Pro...
Page 68 - E. Contact Information; For the location of your nearest Quadra-Fire dealer,; DO NOT DISCARD THIS MANUAL; NOTICE; • Leave this manual with
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 68 E. Contact Information Please contact your Quadra-Fire dealer with any questions or concerns. For the location of your nearest Quadra-Fire dealer, please visit www.Quadra-Fire.com. - NOTES - _____________________________________________________________...