Page 2 - CONTENTS; Section; Wiring the Transmitter/Controller to the Receiver . 12
2 Pelco Manual C585M-B (11/98) CONTENTS Section Page 1.0 GENERAL .................................................................................................. 5 1.1 IMPORTANT SAFEGUARDS AND WARNINGS ............................... 51.2 UNPACKING INSTRUCTIONS .......................................
Page 5 - Only use replacement parts recommended by Pelco.; The product and/or manual may bear the following marks:; RISK OF
Pelco Manual C585M-B (11/98) 5 Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. 1.0 GENERAL 1.1 IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should beobserved. 1. Installation an...
Page 6 - UNPACKING INSTRUCTIONS; Unpack and inspect all parts carefully.; RECOMMENDED TOOLS
6 Pelco Manual C585M-B (11/98) 1.2 UNPACKING INSTRUCTIONS Unpack and inspect all parts carefully. The following items are supplied: 1 MPT8000 Series Wiretron Controller or 1 WX8000 Series Receiver/Driver 1 Installation/Operation Manual (C585M-B) Be sure to save the shipping carton, boxes and inserts...
Page 8 - Same as WX8024RX except for indoor use, 120 VAC input; Wiretron Digital Controller; NEMA Type 1; Wiretron Receiver/Driver
8 Pelco Manual C585M-B (11/98) 2.1.2 Wiretron Receiver/Driver Outdoor WX8024RX Wiretron receiver in weatherproof box for 24 VAC pan/tilts withpower supply for pan/ tilt, zoom lens, 24 VAC camera power,120 VAC input WX8024RX/220 Same as WX8024RX except 230 VAC input WX8115RX Wiretron receiver in weat...
Page 10 - RECEIVER 24 VAC POWER INPUT MODIFICATION; Turn off the power to the receiver and remove the power cord.; Parts needed for modifi-; Circuit Board Electrical Connections
10 Pelco Manual C585M-B (11/98) 3.1 RECEIVER 24 VAC POWER INPUT MODIFICATION The WX8024RX series receivers can be converted to operate with 24 VAC input. To convert the receiver, disconnect the receiver circuit board and assembly fromthe enclosure. The patch panel circuit board is located on the bot...
Page 11 - 4 VAC Power Input Modification Diagram; CAM
Pelco Manual C585M-B (11/98) 11 Figure 4. 24 VAC Power Input Modification Diagram 1 P6 1 P7 T3 T2 T1 24V P/T 24V CAM 28VCT J6 GND J4 J5 F1 F2 F3 8 9 9 9 8 8 J6 J4 J5 66 94V0 9648 J2 J1 J3 1 2 3 4 5 6 7 110V 110V 220V J2 J1 J3 1 3 4 5 6 7 110V 110V 220V J2 J1 J3 1 2 3 4 5 6 7 110V 110V 220V BROWN/WHI...
Page 12 - Determine the best location to install the unit.; Receiver; Control Cable Wiring Distances; Maximum Distance; W h e n i n s t a l l i n g t h e
12 Pelco Manual C585M-B (11/98) 3.2 MOUNTING 3.2.1 Transmitter/Controller Transmitter/controllers in the MPT8000 Series are desktop units. Determine thebest location for the unit. Proceed to Section 3.2.2, RECEIVER. 3.2.2 Receiver 1. Determine the best location to install the unit. 2. Using the WX80...
Page 13 - Prepare the wires from the conductor cable as follows:; Basic Wiretron Interconnect Diagram
Pelco Manual C585M-B (11/98) 13 3.3.1.2 Wiring from the Receiver/Driver to the Pan/Tilt 1. Run multi-conductor cable between the receiver/driver and the pan/tilt (referto Figures 1 and 2.) 2. Assemble the connector parts according to the following instructions. Detail B,in Figure 6, reflects the pin...
Page 14 - Connector Assembly; OR
14 Pelco Manual C585M-B (11/98) Figure 6. Connector Assembly 3. Slide the connector pins into the appropriate holes in the connector body untilthey snap into place. Refer to Figures 4 and 5 for correct pin arrangement,depending on model and options. 4. Push the connector clamp assembly (with boot, i...
Page 15 - Receiver Control Output/Input Pin Assignments
Pelco Manual C585M-B (11/98) 15 Figure 7. Receiver Control Output/Input Pin Assignments 1 4 5 9 15 10 22 16 28 23 33 29 37 34 P1 P2 BRN/W N/C RED/W N/C ORG/W AUX 1 YEL/W N/C GRN/W AUX 4 BLU/W AUX 3 VIO/W AUX 2 GRY/W LOGIC RESET W/GRY GROUND BLK/W +10V BRN P/T COM N/C ORG LEFT GRN DOWN BLU UP VIO RIG...
Page 16 - Mechanical; Jumper Settings on the Receiver Circuit Board; WIRETRON RECEIVER
16 Pelco Manual C585M-B (11/98) 3.3.2 Auxiliary Functions The Wiretron receiver is capable of operating up to four remotely activated auxiliaryfunctions. Each auxiliary output may be individually converted at the receiver formomentary or latching operation. Refer to Figure 8 to set jumpers for auxil...
Page 17 - MANUAL IRIS
Pelco Manual C585M-B (11/98) 17 Figure 10. External Device Wiring Diagram Figure 9. Auxiliary Functions Wiring Diagram WIRETRON 1 2 3 8 MANUAL IRIS GROUND WIRETRON RECEIVER/DRIVER 37-PIN CONNECTOR + 12 VDC NORMALLY-OPENCONTACTS 1N4005 10 VDC RELAY 25 mA COIL CURRENT MAXIMUM CONNECT TO NEGATIVESIDE O...
Page 19 - Fiber Optic Cabling; Power up the controller and receiver.
Pelco Manual C585M-B (11/98) 19 Fiber Optic Cabling Fiber optic transmission of both video and control presents some distinctadvantages. Higher quality and longer distance transmission characteristics,inherent noise resistance, greater flexibility for usage, and reduced cablingdiameter are but a few...
Page 20 - Video Coaxial Cable Wiring Distances; Wire Gauge; Maximum distance from transformer to load; 4 VAC Wiring Distances; otal vA; An enclosure that re-
20 Pelco Manual C585M-B (11/98) Table B. Video Coaxial Cable Wiring Distances Cable Type* Maximum Distance RG59/U 750 ft (229 m) RG6/U 1,000 ft (305 m) RG11/U 1,500 ft (457 m) *Minimum cable requirements: 75 ohms impedanceAll-copper center conductorAll-copper braided shield with 95% braid coverage W...
Page 22 - Also refer to Figure 11 for troubleshooting information.
22 Pelco Manual C585M-B (11/98) 5.0 MAINTENANCE Regularly scheduled maintenance is not required. Clean the outer surface of thecontroller or receiver with a non-abrasive cleaning cloth and antistatic cleaner. Donot use kerosene or similar substances that may damage the surface. 6.0 TROUBLESHOOTING I...
Page 23 - Receiver Pin Assignments
Pelco Manual C585M-B (11/98) 23 6.1 Receiver Pin Assignments Refer to Figure 11, Receiver Pin Assignments, when servicing the receiver. Figure 11. Receiver Pin Assignments PIN 1 RIGHT PIN PIN 2 LEFT PIN 3 UP PIN 4 DOWN PIN 5 ZOOM TELE PIN 6 ZOOM WIDE PIN 7 FOCUS FAR PIN 8 FOCUS NEAR PIN 9 IRIS OPEN ...
Page 25 - MPT8000 Series Controller Dimension Drawing; FRONT VIEW; NOTE: VALUES IN PARENTHESES ARE CENTIMETERS ALL OTHERS ARE INCHES.
Pelco Manual C585M-B (11/98) 25 GENERAL Constructionand Finish: Black polyester powder coated steel OperatingTemperature: 32 ° to 120 ° F (0 ° to 49 ° C) Dimensions: See Figure 12 Weights Unit Shipping MPT8000CZ 7.5 lb (3.36 kg) 8 lb (3.62 kg) MPT8000CZ/220 7.5 lb (3.36 kg) 8 lb (3.62 kg) WX8000 REC...
Page 26 - GENERAL
26 Pelco Manual C585M-B (11/98) Connectors Receiver Input: 3-contact terminal block Receiver Output: 37-pin AMP CPC for control output (mate supplied) Fuse Protection WX8024RX, Fuse 1: Not used WX8024RXI Fuse 2: 2/10 A, 3AG, slow blow fuseFuse 3: 1 A, 3AG, slow blow fuse WX8024RX/220, Fuse 1: Not us...
Page 28 - WARRANTY AND RETURN INFORMATION; WARRANTY
28 Pelco Manual C585M-B (11/98) 8.0 WARRANTY AND RETURN INFORMATION Pelco, the Pelco logo, Camclosure, Esprit,Genex, Legacy, and Spectra are registeredtrademarks of Pelco.Endura and ExSite are trademarks of Pelco. © Copyright 1999, Pelco. All rights reserved. WARRANTY Pelco will repair or replace, w...