Page 2 - IMPORTANT SAFEGUARDS AND WARNINGS
2 C561M-E (8/05) IMPORTANT SAFEGUARDS AND WARNINGS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Installation should be done only by qualified service personnel and conform to all local codes. 6. Use only installation methods and materia...
Page 3 - DESCRIPTION; and Esprit
C561M-E (8/05) 3 DESCRIPTION The WCS1-4 is a mutliple power supply designed for indoor or outdoor applications and is ideal foruse with cameras, domes, and integrated positioning systems such as Spectra ® and Esprit ® . The WCS1-4 is capable of powering up to four units and can handle pan/tilt, heat...
Page 4 - INSTALLATION; MOUNTING INSTRUCTIONS; Mounting to Concrete
4 C561M-E (8/05) INSTALLATION MOUNTING INSTRUCTIONS To mount the power supply directly to a wallboard, wall, or concrete refer to Figures 1 through 3and do the following: 1. Remove the retaining screw from the door latch of the WCS1-4 power supply. 2. Open the door of the WCS1-4 power supply, and th...
Page 5 - breaker before wiring the power supply.
C561M-E (8/05) 5 FUSE INSTALLATION The WCS1-4 power supply is shipped from the factory with a 1.6-amp fuse installed for 100/120 VACinput power. To use input power of 240 VAC, change the 1.6-amp fuse to a 500-milliamp fuse (supplied). To change the fuse remove the lid to the fuse holder (refer to fi...
Page 6 - OUTPUT WIRING; Wiring Connector Diagram
6 C561M-E (8/05) OUTPUT WIRING To install the output wiring to the camera, dome, or positioning system, refer to Figure 4 and do thefollowing: 1. Refer to Table A and determine the output connection needed for your camera, dome, or positioning system. Refer to Figure 4, for the proper connector stri...
Page 7 - CABLE CONNECTIONS AND REQUIREMENTS; Wiring Distances; MAXIMUM DISTANCE FROM TRANSFORMER TO LOAD
C561M-E (8/05) 7 CABLE CONNECTIONS AND REQUIREMENTS Table A. Wiring Distances The following are the recommended maximum distances to wire the WCS1-4 to a Spectra III orEsprit positioning system. To determine the correct voltage tap: 1. Pick the unit type. 2. Find the wire gauge used (22 gauge is not...
Page 8 - MAINTENANCE
8 C561M-E (8/05) MAINTENANCE There are no user-serviceable parts except for the fuse. If the transformer in the WCS1-4 does notwork properly, the entire environmental power supply needs to be returned to the factory for repair.Refer to the Warranty and Return Information for instructions on returnin...
Page 9 - SPECIFICATIONS; ELECTRICAL
C561M-E (8/05) 9 SPECIFICATIONS ELECTRICAL Input Voltage: Selectable 100, 120, 240 VAC, 50/60 Hz via the Primary Line Input connectorstrip Output Voltage/Power: Selectable 24 VAC (Tap A), 26 VAC (Tap B), or 28 VAC (Tap C) at 100 VA viathe Secondary Output Tap’s connector strip Fusing: One fuse. Sele...
Page 10 - WCS1-4 Dimension Drawing
10 C561M-E (8/05) Figure 5. WCS1-4 Dimension Drawing NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES. 6.50 (16.51) 5.63 (14.30) 4.50 (11.43) 6.44 5.88 (14.94) 4.00 (10.16) 7.88 (20.02) (16.36)
Page 11 - WARRANTY AND RETURN INFORMATION; REVISION HISTORY
C561M-E (8/05) 11 WARRANTY AND RETURN INFORMATION ® Pelco, the Pelco logo, Spectra, Genex, Coaxitron, Legacy, Esprit, Camclosure, Spectra III, and Spectra III SE are registered trademarks of Pelco. © Copyright 2003, Pelco. All rights reserved. REVISION HISTORY Manual # Date Comments C561M 11/97 Orig...