Page 2 - Contents
2 C3446M (7/08) Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 3 - List of Illustrations
C3446M (7/08) 3 List of Illustrations 1 DHCP Network Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2 Endura Network Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 4 - Important Safety Instructions
4 C3446M (7/08) Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 7. On...
Page 5 - Regulatory Notices; RADIO AND TELEVISION INTERFERENCE
C3446M (7/08) 5 Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired ...
Page 6 - Description; SYSTEM MODELS
6 C3446M (7/08) Description The Spectra ® Mini IP dome system is an indoor mini dome system with a built-in 100Base-TX network interface for live streaming to a standard Web browser (Microsoft ® Internet Explorer ® or Firefox ® ). The Spectra Mini IP dome features open architecture connectivity for ...
Page 7 - PARTS LIST
C3446M (7/08) 7 PARTS LIST The following parts are supplied with the Spectra Mini IP dome system: The following parts, in addition to the normal installation tools, are needed but not supplied: Qty Description 1 Dome drive 1 Dome bubble with trim ring 1 Installation manual (C3446M) 1 Operation/Confi...
Page 8 - BASIC SYSTEM CONFIGURATIONS
8 C3446M (7/08) BASIC SYSTEM CONFIGURATIONS The following illustrations demonstrate the possible configurations of Spectra Mini IP with a variety of network options. IMPORTANT NOTE. PLEASE READ . The network implementations in this document are shown as general representations only and are not inten...
Page 9 - DHCP NETWORK; ENDURA NETWORK
C3446M (7/08) 9 DHCP NETWORK In this configuration, the DHCP network is accessed through the Web browser. NOTE: For a secure network, Pelco recommends placing the dome behind a firewall. Refer to Table A on page 8. Figure 1. DHCP Network Example ENDURA NETWORK Refer to Table A on page 8. Figure 2. E...
Page 10 - PRIVATE NETWORK
10 C3446M (7/08) PRIVATE NETWORK When using a private network, the PC used to operate the Web browser acts as the server. If a static IP network is being used rather than a DHCP network, the dome system is assigned a default IP address of 192.168.0.20 on netmask 255.255.0.0. After the first dome sys...
Page 11 - STATIC NETWORK
C3446M (7/08) 11 STATIC NETWORK When using a static network, the PC used to operate the Web browser must use the same subnet mask as the dome systems to which it is connected. When the first dome system is plugged into the network, it is assigned a default IP address of 192.168.0.20 on netmask 255.2...
Page 12 - Cover and Back Box Installation; SURFACE MOUNT INSTALLATION
12 C3446M (7/08) Cover and Back Box Installation The Spectra Mini IP is an indoor dome system designed for ceiling applications. The dome can be mounted to the surface of ceilings, or it can be recessed in hard ceilings or standard 2 x 2 ft (61 x 61 cm) tiles in suspended ceilings. SURFACE MOUNT INS...
Page 14 - RECESSED INSTALLATION; SUSPENDED CEILING
14 C3446M (7/08) RECESSED INSTALLATION SUSPENDED CEILING 1. Remove the spring paddle flex assembly from the surface mount ring (refer to Figure 7). Figure 7. Spring Paddle Flex Assembly 2. Remove the surface mount ring from the dome drive as follows (refer to Figure 8 on page 15): a. Place fingers o...
Page 16 - HARD CEILING
16 C3446M (7/08) HARD CEILING 1. Remove the spring paddle flex assembly from the surface mount ring. 2. Remove the surface mount ring from the dome drive as follows (refer to Figure 8 on page 15): a. Place fingers on the circular marks located on the sides of the surface mount ring. b. Pinch the sid...
Page 17 - Wiring Tables; CAT5 CABLE
C3446M (7/08) 17 Wiring Tables CAT5 CABLE Connect a Cat5 cable to the RJ-45 network connector. The 8-pin RJ-45 connector includes video and PoE for the dome system. PoE (IEEE 802.3af) injects power over the same cabling that carries the network data, eliminating the need for a separate power supply;...
Page 18 - CONNECTING A RELAY DEVICE
18 C3446M (7/08) 24 VAC CONNECTIONS (OPTIONAL) If PoE is not used, the camera includes a 24 VAC power connector. Connect the power cable to the 2-pin power connector on the back of the camera using the terminal block connector (provided). Refer to Recommended Wire Gauge and Wiring Distances on page ...
Page 19 - CONNECTING ALARMS; SUPERVISED ALARMS
C3446M (7/08) 19 CONNECTING ALARMS The Spectra Mini IP provides an alarm input for external signaling devices, such as door contacts or motion detectors. Both normally open and normally closed devices are supported. SUPERVISED ALARMS When an alarm is configured as a supervised alarm, Spectra Mini IP...
Page 20 - UNSUPERVISED ALARMS
20 C3446M (7/08) UNSUPERVISED ALARMS When an alarm is configured as an unsupervised alarm, the dome system only triggers an alarm when the normal alarm state (normally open or normally closed) changes. Figure 15 shows the alarm and no alarm conditions of an unsupervised alarm input. A normally close...
Page 21 - ALARM CONNECTIONS
C3446M (7/08) 21 ALARM CONNECTIONS Refer to Figure 10 on page 17 for additional wiring information. The alarm is internally connected to the Spectra Mini IP chassis. Do not connect directly to any potential except chassis ground. Figure 18. Unsupervised Alarm Input Wiring Alarm Return: Alarm - Alarm...
Page 22 - Reset Button
22 C3446M (7/08) Reset Button Use the reset button located underneath the trim ring on the mounting flange to access the following modes: To access one of these modes: 1. Press and hold the reset button. The unit starts cycling through the modes; hold the button for four seconds to access (cycle thr...
Page 23 - Troubleshooting
C3446M (7/08) 23 Troubleshooting Problem Possible Cause Suggested Remedy No video PoE power issue • Check Cat5 cable connection.• Verify PoE is enabled.• Disconnect the network cable and then reconnect it to the dome system. Check the LED on the trim ring to verify that it is flashing green, indicat...
Page 25 - Specifications; MECHANICAL
C3446M (7/08) 25 Specifications MECHANICAL Pan Movement 360° continuous pan rotation Vertical Tilt Unobstructed +2° to -92° Manual Pan/Tilt Speeds Pan 0.4-80°/sec manual operation, 100°/sec turbo Tilt 0.7-40°/sec manual operation Preset Speeds Pan 140°/sec Tilt 80°/secFor variable speed operation an...
Page 26 - LENS
26 C3446M (7/08) LENS Lens f/1.8 (focal length, 4.2~42 mm) Zoom 10X optical zoom, 8X digital zoom Zoom Speed (optical range) 1.5/2.5/4.3 seconds Horizontal Angle of View 46.4° wide zoom5.0° telephoto zoom Focus Automatic with manual override Iris Control Automatic with manual override (Design and pr...
Page 27 - PRODUCT WARRANTY AND RETURN INFORMATION
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on fiber optic products and TW3...