2 Pelco Manual C342M-D (8/05) CONTENTS Section Page 1.0 GENERAL .................................................................................................. 5 1.1 IMPORTANT SAFEGUARDS AND WARNINGS ............................... 5 2.0 DESCRIPTION ..................................................
Page 3 - Updated wiring instructions for EH8106L enclosures.
Pelco Manual C342M-D (8/05) 3 LIST OF ILLUSTRATIONS Figure Page 1 Removing the Screws ........................................................................ 8 2 Releasing the Covers ........................................................................ 8 3 Removing the Covers ......................
Page 5 - Only use replacement parts recommended by Pelco.
Pelco Manual C342M-D (8/05) 5 Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. 1.0 GENERAL 1.1 IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should beobserved. 1. Installation and...
Page 8 - PAN AND TILT LIMIT STOP ADJUSTMENTS; Removing the Screws
8 Pelco Manual C342M-D (8/05) 3.2 PAN AND TILT LIMIT STOP ADJUSTMENTS 1. Remove the covers. a. Refer to Figure 1 and remove the Phillips screw on each side of the pan/tilt unit. b. Refer to Figure 2 and place your hands under the cover halves. Exert astrong, upward force to release the covers from t...
Page 9 - Replacing the Cover Halves; If you need to readjust the; Tilt Limit Adjustment; Never remove; Pan Limit Adjustment; SL models do not have pan
Pelco Manual C342M-D (8/05) 9 2. Adjust the tilt limit stops. Refer to Figure 5 for the location of the tilt limit stops. The tilt limit stop closestto the front of the pan/tilt unit limits the downward movement. The tilt limit stopclosest to the back of the pan/tilt unit limits the upward movement....
Page 11 - Connector Assembly; OR; FRONT VIEW; To prevent damage to
Pelco Manual C342M-D (8/05) 11 Refer to Figure 9 and the following steps to construct the cable: 1. Slide the unshielded and coaxial cables through the cable shell and rubberboot. 2. Strip one inch of the jacket from the cables. 3. For the unshielded conductors, strip 1/8 inch of insulation from the...
Page 12 - Wiper On/Off Connection
12 Pelco Manual C342M-D (8/05) Figure 10. Wiper On/Off Connection
Page 13 - Function; 7-Position Connector Pin Designations for Pan/Tilts with
Pelco Manual C342M-D (8/05) 13 Pin # Function PT780P PT780P/PP PT780-SL PT780-SL/PP PT780-24P PT780-24P/PP PT780-24SL PT780-24SL/PP PT780-VS PT780-VS/PP PT780-VSSL PT780-VSSL/PP Coaxial Cable 27/4 Video Signal/Ground • • • • 30/4 Sync Signal/Ground (B) (B) (B) (B) Unshielded Conductors 3 Left • • • ...
Page 15 - Requirements to Wire Power to Pan and Tilt Motors; Maximum Cable Length*
Pelco Manual C342M-D (8/05) 15 Table B. Requirements to Wire Power to Pan and Tilt Motors Maximum Cable Length* Wire Size 6 Conductors** 7 Conductors*** 5 Conductors**** 120 VACPT780P Models20 AWG 1,370 ft (417 m) 2,745 ft (836 m) 18 AWG 2,180 ft (664 m) 4,370 ft (1,331 m) 16 AWG 3,470 ft (1,057 m) ...
Page 16 - Maximum Cable Distances Using RB24 or RB115 Relay Boxes; RELAY; Wire Size; Use Table B
16 Pelco Manual C342M-D (8/05) Table C. Maximum Cable Distances Using RB24 or RB115 Relay Boxes RELAY BOX CONTROL A B REQUIRED EXTERNALPOWER SUPPLY Wire Size Maximum “A” Maximum “B” Distance Distance 20 AWG* 5,800 ft (1,768 m) 18 AWG 8,250 ft (2,515 m) Use Table B 16 AWG 13,000 ft (3,962 m) * Not re...
Page 17 - Requirements to Wire Power to Camera Enclosure; Option; Requirements to Wire Power for Optional Heater Blanket; same power
Pelco Manual C342M-D (8/05) 17 Table D. Requirements to Wire Power to Camera Enclosure Option Power HB1 120 VAC (40 watts) HB2 24 VAC (40 watts) HB3 230 VAC (40 watts) Table E. Requirements to Wire Power for Optional Heater Blanket EH4700L and EH5700L: To determine the wire gauge to use, add up the ...
Page 18 - 4 VAC Wiring Distances Chart; Wire Gauge; Maximum distance from transformer to load; An enclosure that re-
18 Pelco Manual C342M-D (8/05) Table F. 24 VAC Wiring Distances Chart Wire Gauge Maximum distance from transformer to load The following are the recommended maximum distances for 24 VAC applicationsand are calculated with a 10-percent voltage drop. (Ten percent is generally themaximum allowable volt...
Page 19 - C) and turn off at 60
Pelco Manual C342M-D (8/05) 19 4.0 OPERATION Refer to the manual for your control equipment for operating the pan/tilt unit. If your enclosure has the heater blanket option, it is thermostatically controlled toturn on at 40 ° F (4.44 ° C) and turn off at 60 ° F (15.56 ° C). The heater blanket allows...
Page 20 - Pan/Tilt Adjustments
20 Pelco Manual C342M-D (8/05) 5.0 MAINTENANCE If you need to remove the enclosure, protect the RediLINK™ connector area againstmoisture, dust, dirt, etc. Failure to do so could result in a bad connection. Also,damage to the pan/tilt unit or enclosure could occur when power is turned on. The followi...
Page 23 - PT780 Series Dimension Drawing; GENERAL
Pelco Manual C342M-D (8/05) 23 Figure 12. PT780 Series Dimension Drawing 11.10 (28.19) .70 (1.78) PELCO 8.50 (21.59) 9.60 (24.38) Ø 4.00 (10.16) Ø 3.50 (8.89) 1/4-20 D&T X .50 (1.27)USABLE THREAD DEPTHEQUALLY SPACED ON A 2.25 (5.72) B.C. NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS AR...
Page 24 - WARRANTY AND RETURN INFORMATION; WARRANTY; RETURNS
24 Pelco Manual C342M-D (8/05) 7.0 WARRANTY AND RETURN INFORMATION ® Pelco, the Pelco logo, Spectra, Esprit, Genex, Legacy, and Camclosure are registered trademarksof Pelco. ™ Endura and ExSite are trademarks of Pelco. © Copyright 2005, Pelco. All rights reserved. WARRANTY Pelco will repair or repla...