Page 3 - CONTENTS; LIST OF ILLUSTRATIONS
Pelco Manual C1982M-A (12/00) [ 3 ] CONTENTS IMPORTANT SAFEGUARDS AND WARNINGS ................................................................................. 4 REGULATORY NOTICES .................................................................................................................... 4...
Page 4 - IMPORTANT SAFEGUARDS AND WARNINGS; REGULATORY NOTICES
[ 4 ] Pelco Manual C1982M-A (12/00) IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service and installation personnel. 2. Installation shall be done in accordan...
Page 5 - DESCRIPTION; Models
Pelco Manual C1982M-A (12/00) [ 5 ] DESCRIPTION The MC3500 and MC3600 Series are compact, monochrome video cameras with a 1/3-inch CCD imager. Allcameras have a direct drive/auto iris lens connector and adjustable back focus, and accept C and CS lenses. Models MC3500S-2 Standard resolution, 330 TV l...
Page 6 - CAMERA LAYOUT; Figure 1. Camera Layout; INSTALLATION; Lens Mounting; Loosen the two back focus locking screws. Rotate the back focus
[ 6 ] Pelco Manual C1982M-A (12/00) CAMERA LAYOUT Figure 1. Camera Layout NOTE: The cosmetic trim ring conceals the LED light for more discreet surveillance operations.The trim ring also hides the power connectors and protects the DIP switches. INSTALLATION Lens Mounting The MC3500 and MC3600 Series...
Page 7 - Not used; Camera Mounting; To change the mount adapter position:; Figure 3. Camera Mounting
Pelco Manual C1982M-A (12/00) [ 7 ] 3 4 1 2 PIN DD LENS CONNECTIONS AI LENS CONNECTIONS 1 Control coil negative (-) Not used 2 Control coil positive (+) Lens positive supply 3 Drive coil positive (+) Video drive signal 4 Drive coil negative (-) Ground Figure 2. DD/AI Lens Connector Camera Mounting U...
Page 8 - POWER AND VIDEO CONNECTIONS; Power Connections; Figure 4. Power Supply Connections
[ 8 ] Pelco Manual C1982M-A (12/00) POWER AND VIDEO CONNECTIONS To connect the camera power and video do the following: 1. Remove the rear cover from the camera (refer to Figure 1). Thread cabling through the rear cover. 2. Connect the power cable to the two pin power connector on the back of the ca...
Page 9 - would require a minimum wire gauge of 20 AWG.
Pelco Manual C1982M-A (12/00) [ 9 ] Table A. Recommended Wire Gauge and Wiring Distances The following are the recommended maximum distances for 24 VAC applications and are calculatedwith a 10-percent voltage drop. (Ten percent is generally the maximum allowable voltage drop forAC-powered devices.) ...
Page 10 - Figure 5. AGC and EI Switch Settings
[ 10 ] Pelco Manual C1982M-A (12/00) LENS SETUP AND FOCUS PROCEDURESVideo Drive Auto Iris Lens When a video drive auto iris lens is used, the lens mode selector switch must be set to AI. Switch theEI and AGC OFF. Refer to the lens instructions and adjust the lens for the optimum picture (video out-p...
Page 11 - BACK FOCUS ADJUSTMENT; To adjust the back focus:; Figure 6. Back Focus Adjustment
Pelco Manual C1982M-A (12/00) [ 11 ] BACK FOCUS ADJUSTMENT The back focus adjustment is located at the front of the camera and is accessible from either side ofthe case. To adjust the back focus: 1. Loosen the two back focus locking screws (one on each side). 2. Turn the back focus ring: a. Clockwis...
Page 12 - SWITCH SETTINGS; Figure 7. Switch Settings; LL/INT Synchronization Selection; Gamma HI
[ 12 ] Pelco Manual C1982M-A (12/00) SWITCH SETTINGS Figure 7. Switch Settings 10 LL/INT Synchronization Selection Locks the frame rate to the power supply frequency. Eliminates verticalroll caused by multiple cameras connected to the same switching de-vice. Each camera output is synchronized to the...
Page 13 - Figure 8. BLC Setup Switches
Pelco Manual C1982M-A (12/00) [ 13 ] 4 EI ON/EI OFF (Electronic Iris) The EI (Electronic Iris) feature compensates for an excessive light level by automatically adjustingshutter speed. When the EI is ON, the DD lens level potentiometer on the side of the camera maybe used to adjust the EI threshold ...
Page 14 - CAMERA PHASE ADJUSTMENT; To synchronize the cameras do the following:
[ 14 ] Pelco Manual C1982M-A (12/00) CAMERA PHASE ADJUSTMENT When using one AC power supply in a multi camera system, a brief vertical roll may occur on themonitor each time a camera view is switched. To eliminate vertical roll, adjust the phase control tosynchronize (line-lock), the cameras to one ...
Page 15 - SPECIFICATIONS; GENERAL
Pelco Manual C1982M-A (12/00) [ 15 ] SPECIFICATIONS GENERAL CCD Sensor: 1/3-inch Synchronization System: AC line lock or internal oscillator Horizontal Resolution MC3500S-2: 380 TV lines MC3600H-2: 570 TV lines Iris Control: Electronic/passive Minimum Illumination MC3500S-2: 0.1 lux at f1.2 MC3600H-...
Page 16 - Date; PRODUCT WARRANTY AND RETURN INFORMATION
[ 16 ] Pelco Manual C1982M-A (12/00) Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco. Endura and ExSite are trademarks of Pelco. HyperHAD and EXview HAD CCD are trademarks of the Sony Corporation. © Copyright 2000, Pelco. All rights reserved. ...