Page 2 - ii
TABLE OF CONTENTS Section Page 1.0 WARNINGS ........................................................................................................................................ 1 2.0 SCOPE ..............................................................................................................
Page 3 - iii
TABLE OF CONTENTS (Continued) Section Page 4.8 LOCATION ID SETUP ............................................................................................................ 184.8.1 Location ID Program .....................................................................................................
Page 5 - prior to installation and operation.; literature accompanying this unit.; RISK OF ELECTRIC SHOCK.; CAUTION; Only use replacement parts recommended by Pelco.
Pelco Manual C1000M-B (1/96) 1 Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. This symbol indicates that there are importantoperating and maintenance instructions in the literature accompanying this unit. CAUTION: RISK OF ELECTRIC SHOC...
Page 7 - Do not power up the Inter-; BASIC INSTALLATIONS; For basic installations, perform the following steps:
Pelco Manual C1000M-B (1/96) 3 Figure 1. Basic ICI1000S Configuration Wiring Diagram 3.0 INSTALLATION To begin installation, refer to the following instructionsand Figures 1 and 2. 3.1 INSTALLING INTERFACE CABLE 1. Install interface cable and PIM (if applicable) intothe cash register according to th...
Page 8 - Wiring Configuration; Figure 2. ICI1000PIM Wiring Configuration
4 Pelco Manual C1000M-B (1/96) Figure 3. Standard RS-232 Style Wiring Configuration Figure 2. ICI1000PIM Wiring Configuration BL YL GR To Inter-Check Unit Straight throughphone cable User-supplied cable.18 AWG shielded wire issuggested BL YL GR From ICI1000PIM BL YL GR To Inter-Check Unit Straight t...
Page 9 - Figure 4. Printer Output and Alarm Input Wiring; ICI1000SI models have an internal
Pelco Manual C1000M-B (1/96) 5 Figure 4. Printer Output and Alarm Input Wiring 3. Connect the data cable from the register interfacecable (or PIM) to “DATA IN” on the Inter-CheckICI1000S, using the ICI1000WK and 18 gauge, 2-conductor shielded cable (see Figure 1). 4. If using alarms, attach a 22-gau...
Page 10 - V H
6 Pelco Manual C1000M-B (1/96) Figure 5. Video Adjustment Locations 3.3 VIDEO ADJUSTMENTS All video adjustments are located on the bottom ofthe Inter-Check unit (refer to Figure 5). Using a non-metallic screwdriver, make any necessary adjustmentsas follows: • Horizontal Positioning adjusts the heigh...
Page 11 - Figure 6. Keypad Layout; Power down the Inter-Check ICI1000SI unit.; THE NV MEMORY WRITE PROTECT; Please familiarize yourself with the
Pelco Manual C1000M-B (1/96) 7 Figure 6. Keypad Layout 1. Power down the Inter-Check ICI1000SI unit. 2. Remove the four cover screws with a Phillipsscrewdriver and set the cover aside. 3. Power up the ICI1000SI unit. 4. Program the Inter-Check unit for your particularapplication. 5. When finished pr...
Page 12 - ICI1000S PROGRAMMING MENU TREE; ENT
8 Pelco Manual C1000M-B (1/96) ICI1000S PROGRAMMING MENU TREE Monitoring Mode ↵ ENT Main Program Menu 1. Channel 1 Setup 2. System Parameters 3. Clock Setup 4. Location ID Setup 5. Customer Header 6. Diagnostics 7. Alarm Inputs Channel Program Menu 1. Communication Setup 2. Data Format/Communica-tio...
Page 14 - PROTOCOL
10 Pelco Manual C1000M-B (1/96) 1=ASCII OR 2=EBCDIC The fifth prompt sets up the character set for the Inter-Check ICI1000S Series. Press a “1” to select ASCIIand “2” for EBCDIC. The ASCII character set is themost common whereas EBCDIC is used predominantlyin IBM systems. Select ASCII when connectin...
Page 18 - Exception Alarm Text Edit
14 Pelco Manual C1000M-B (1/96) 4.6.6 Exception Alarm Text Edit (Selection #6 in the System Program Menu) After Pressing #6 the following numbers will appearacross your monitor screen: 12345678901234567890123456789012345678901234567890 = = This row of numbers is referred to as the ExceptionColumn Li...
Page 19 - Exceptions Using the GLOBAL Strategy
Pelco Manual C1000M-B (1/96) 15 Exceptions Using the COLUMN SPECIFICStrategy This is used to flag on specific placement of text onthe register ticket. This type of exception uses the (^)character on your keypad. It is used to capture text ac-cording to the position on the register ticket. When thist...
Page 20 - Exception Flagging Using WILDCARDS
16 Pelco Manual C1000M-B (1/96) Exception Flagging Using WILDCARDS Used to flag on groups of transactions or departments.This type of exception also uses the caret (^) characterand is usually used with the COLUMN SPECIFIC typeof exception. Again, it is suggested that you use theEXCEPTION COLUMN LINE...
Page 21 - Exception Column Line; The internal clock on the Inter-Check
Pelco Manual C1000M-B (1/96) 17 Notice that the second double bar is placed directly af-ter the data you are interested in. This format holds truefor any transaction you wish to flag using the doublebar format. The first double bar has a leeway of 15 char-acters or spaces. In other words, in the pre...
Page 22 - LOCATION ID SETUP; LOCATION ID SETUP MENU
18 Pelco Manual C1000M-B (1/96) 4.7.2 Clock ID On and Screen Position Set Selection 2 in the CLOCK PROGRAM MENU willturn the clock on and allow positioning on the screen.Press the arrow keys twice for each increment to movethe time and date to the preferred position and pressENT to save. 4.7.3 Clock...
Page 23 - DIAGNOSTICS; Some of the tests selected in the
Pelco Manual C1000M-B (1/96) 19 4.8.2 Location ID On and ScreenPosition Set Pressing 2 in the LOCATION ID SETUP MENU willturn the ID on at all times. It also allows you to posi-tion the ID with the cursor control keys to the desiredscreen display position. 4.8.3 Location ID Off Pressing 3 will turn ...
Page 24 - For complete pin-out; Figure 7 . Program Transfer Wiring Diagram
20 Pelco Manual C1000M-B (1/96) 4.10.4 Memory Tests By entering 4 in this menu the following sub-menu isdisplayed: MEMORY TEST MENU 1. RAM TEST2. VIDEO RAM TEST3. (DL) NV MEMORY TEST4. ROM CRC TEST By selecting 1, the unit will perform a self test on itsRandom Access Memory. This test is used to ver...
Page 26 - Figure 8. Printer Output and Alarm Input Wiring; For a complete table of status label
22 Pelco Manual C1000M-B (1/96) Figure 8. Printer Output and Alarm Input Wiring 4.11 ALARM INPUT (Selection #7 from the main menu) The ALARM INPUT can be connected to any normallyopen (open loop) alarm device that can trigger a clo-sure for at least one-half second. Once an alarm is valid,the trigge...
Page 27 - Each time you change any of the pa-; Alarm Programming; In the following examples, underlined
Pelco Manual C1000M-B (1/96) 23 4.11.2 Alarm Trigger Dwell Selection #2 enables you to program the amount of timethat the ALARM INPUT closure must be present inorder for the Inter-Check ICI1000S Series to recognizeit as a valid alarm condition. To program this option,simply enter a suitable value be...
Page 30 - TROUBLESHOOTING FLOW CHART
26 Pelco Manual C1000M-B (1/96) 5.1 TROUBLESHOOTING FLOW CHART
Page 33 - APPENDIX A. HEXADECIMAL, DECIMAL AND BINARY CONVERSION TABLES
Pelco Manual C1000M-B (1/96) 29 APPENDIX A. HEXADECIMAL, DECIMAL AND BINARY CONVERSION TABLES 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 1 2 2 0 0 0 0 0 0 1 0 3 3 0 0 0 0 0 0 1 1 4 4 0 0 0 0 0 1 0 0 5 5 0 0 0 0 0 1 0 1 6 6 0 0 0 0 0 1 1 0 7 7 0 0 0 0 0 1 1 1 8 8 0 0 0 0 1 0 0 0 9 9 0 0 0 0 1 0 0 1 A 1 0 ...
Page 36 - POLLING PIM ADDRESS
32 Pelco Manual C1000M-B (1/96) Installation instructions for configuring the ICI1000PIMinterface module are provided under separate cover inmanual C1005M-D. If for some reason this manual is not readily available,refer to the following section to configure the switchsettings on the PIM interface mo...
Page 37 - Register
Pelco Manual C1000M-B (1/96) 33 SWITCH BANK #2 This switch is dedicated to selecting which type of cashregister the ICI1000PIM is interfacing with. The tablebelow indicates the appropriate switch settings for aparticular cash register. The first three settings indicatethe appropriate settings for sw...
Page 39 - Figure 9. ICI1000PIM Switch Settings; In rare instances when connecting a
Pelco Manual C1000M-B (1/96) 35 Figure 9. ICI1000PIM Switch Settings ICI1000PIM INSTALLATION/TROUBLESHOOTING GUIDELINES Listed below are some simple troubleshooting steps atyour disposal. Following these steps will ensure thatyour Inter-Check P.O.S. unit is communicating correctlywith your ICI1000PI...
Page 40 - Pelco
36 Pelco Manual C1000M-B (1/96) Pelco 3500 Pelco Way, Clovis, CA 93612-5699 (209) 292-1981 • (800) 289-9100 FAX (800) 289-9150 or (209) 292-3827 (Product specifications subject to change without notice.) C1000M-B ®