Page 2 - REVISION HISTORY; CONTENTS; LIST OF ILLUSTRATIONS
2 Pelco Manual C1466M-A (5/98) REVISION HISTORY Manual # Date Comments C1466M 6/97 Original version. C1466M-A 5/98 Rev A. Added tamper switch for HS8080 model only.Changed manual pagination. CONTENTS Section Page 1.0 GENERAL ..............................................................................
Page 3 - Only use replacement parts recommended by Pelco.; The product and/or manual may bear the following marks:; RISK OF
Pelco Manual C1466M-A (5/98) 3 Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. 1.0 GENERAL 1.1 IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should beobserved. 1. Installation an...
Page 5 - window is supplied with
Pelco Manual C1466M-A (5/98) 5 2.0 DESCRIPTION The information within this manual covers the installation of the HS8080/HS8134low-profile high security enclosures. The HS8080/HS8134 are high security ceiling mount enclosures designed for in-stallations such as prisons, detention cells, etc., requiri...
Page 6 - ENCLOSURE INSTALLATION; To mount the HS8080/HS8134 enclosure, perform the following steps:; CAMERA AND LENS INSTALLATION; Mount the camera/lens onto the camera cradle.
6 Pelco Manual C1466M-A (5/98) 3.0 INSTALLATION 3.1 ENCLOSURE INSTALLATION To mount the HS8080/HS8134 enclosure, perform the following steps: 1. Determine the location and direction of the enclosure to be mounted. 2. Unlock the cover by unscrewing the tamper-resistant screw. (Pin-in-hex wrenchinclud...
Page 7 - Video Coaxial Cable Wiring Distances; Maximum Distance; Wire Gauge; Maximum distance from transformer to load; 4 VAC Wiring Distances; otal vA; An enclosure that re-
Pelco Manual C1466M-A (5/98) 7 Table A. Video Coaxial Cable Wiring Distances Cable Type* Maximum Distance RG59 750 ft (229 m) RG6 1,000 ft (305 m) RG11 1,500 ft (457m ) * Minimum cable requirements: 75 ohmsAll-copper center conductorAll-copper braided shield with 95-percent braid coverage Wire Gauge...
Page 10 - ELECTRICAL
10 Pelco Manual C1466M-A (5/98) Max. Camera/Lens Size: 3.5" H x 9.75" L x 3.0" W (8.89 x 24.77 x 7.62 cm)* * Dimensions include BNC connector Length may vary if width and height of camera and lens aredifferent. Camera Mounting: Removable, adjustable camera cradle Lock: Tamper-resistant 8...
Page 11 - NOTES
Page 12 - WARRANTY AND RETURN INFORMATION; WARRANTY; RETURNS
12 Pelco Manual C1466M-A (5/98) 6.0 WARRANTY AND RETURN INFORMATION Pelco, the Pelco logo, Camclosure, Esprit,Genex, Legacy, and Spectra are registeredtrademarks of Pelco.Endura and ExSite are trademarks of Pelco. © Copyright 1998, Pelco. All rights reserved. WARRANTY Pelco will repair or replace, w...