Pelco HB6000/220 - Manuals

Pelco HB6000/220 – Manual in PDF format online.

Manuals:

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8

Summary

Page 2 - When using a single power

2 Pelco Manual C496M (12/90) 3.1 MODELS HB6000 120 VAC thermostatically controlledheater and blower. Heater provides80 watts of heat and activates ON at40 ° F (4.44 ° C) and OFF at 60 ° F (15.56 ° C). Blower provides internal air circulation (12 cfm at 4 watts) andactivates ON at 110 ° F (43.33 ° C)...

Page 3 - POWER REQUIREMENTS; Open the cover or access door.

Pelco Manual C496M (12/90) 3 3.4 POWER REQUIREMENTS The blower and heater require a 24 VAC/120 VAC/230VAC, 50/60 Hz single phase power source. They usethe following wattage when in operation. Blower: 4.5 watts Heater: 80 watts 4.0 INSTALLATION To install the HB6000, HB6000/220, and HB6024 per-form t...

Page 4 - The blower is factory wired to the PCB assembly.; ELECTRICAL CONNECTION

4 Pelco Manual C496M (12/90) 4.3 HEATER/BLOWER WIRING The blower is factory wired to the PCB assembly. Connect the heaters to the PCB assembly as shown inthe respective wiring diagrams (refer to Figure 2, Fig-ure 3, or Figure 4). Supply AC line voltage (230 VAC, 120 VAC, or 24 VAC)as shown. 4.4 ELEC...