Page 2 - CONTENTS; Section
2 C312M-A (12/02) CONTENTS Section Page DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 MODELS . . . . . . . . . . . ....
Page 3 - LIST OF ILLUSTRATIONS; Figure; LIST OF TABLES; Table
C312M-A (12/02) 3 LIST OF ILLUSTRATIONS Figure Page 1 POD 100 Attachment to the Tilt Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2 Cable Connections . . . . . . . . . . . . . ....
Page 4 - DESCRIPTION; MODELS
4 C312M-A (12/02) DESCRIPTION The ES30-ISAP is an innovative addition to the Esprit ® Series Positioning System family designed specifically for the POD 100 Thermal Imager (not supplied). The system includes the Esprit receiver, pan and tilt, power supply, and an exclusively designed connector andmo...
Page 5 - INSTALLATION
C312M-A (12/02) 5 INSTALLATION POD 100 1. Refer to Figure 1 and attach the POD 100 to the tilt table of the Esprit with the 1/4-20 x .50-inch screw (supplied). POD100 TILT TABLE ESPRIT PANAND TILTSYSTEM Figure 1. POD 100 Attachment to the Tilt Table 2. Refer to Figure 2 and attach the harness cable ...
Page 6 - PAN AND TILT
6 C312M-A (12/02) PAN AND TILT 1. Remove the transformer module from the base of the system by loosening the four Phillips screws and lifting the module. 01475 BASE MOUNTINGSCREWS MOUNT LOOSENPHILLIPSSCREWS TRANSFORMERMODULE BASE 2. Attach the base of the system to an Esprit mount (EWM or EPP) with ...
Page 9 - TXB SERIES TRANSLATOR BOARD INSTALLATION (OPTIONAL); HOW TO REMOVE THE PAN AND TILT COVER; HOW TO REINSTALL THE PAN AND TILT COVER
C312M-A (12/02) 9 TXB SERIES TRANSLATOR BOARD INSTALLATION (OPTIONAL) Pelco’s TXB Series allows controllers from other companies to communicate with the Esprit system. To install a TXB Series board, remove the left cover of the pan and tilt. Once the cover is removed, refer to the manual supplied wi...
Page 11 - OPERATION; PAN AND TILT OPERATION
C312M-A (12/02) 11 OPERATION POWER-UP DISPLAY When the Esprit system is powered up or reset, the selected protocol, revision number, and other information is displayed on the monitor.The information remains on the monitor until the system is moved. PAN AND TILT OPERATION Operation How to Control Pan...
Page 12 - OPERATING NOTES; ENVIRONMENTAL RANGE; Controller; LENS FUNCTIONS
12 C312M-A (12/02) OPERATING NOTES ENVIRONMENTAL RANGE The operating temperature ranges from a minimum of -40 ° F (-40 ° C) to a maximum of 122 ° F (50 ° C) for sustained system operation or 140 ° F (60 ° C) absolute maximum. PAN AND TILT FUNCTIONS Controller Pan Tilt Type (Capability, 360 ° Continu...
Page 13 - ZONES; PATTERNS
C312M-A (12/02) 13 RANDOM, FRAME, AND AUTO SCANNING Select preset 97 (30) to start random scanning. Select preset 98 (31) to activate frame scanning (three seconds of scanning followed by athree-second pause). Select preset 99 (32) to start auto (continuous) scanning. Scan limit stops are controlled...
Page 14 - QUICK START GUIDE – SYSTEM SETUP; PROGRAMMING GUIDE – ES30-ISAP PAN AND AND TILT SYSTEM; PRESETS
14 C312M-A (12/02) QUICK START GUIDE – SYSTEM SETUP PROGRAMMING GUIDE – ES30-ISAP PAN AND AND TILT SYSTEM 1. Access main menu (preset 95). 2. Make main menu selections. Joystick: Move up or down to position cursor or to toggle between selections. Iris Open: Enter. Iris Close: Cancel. MAIN MENU <C...
Page 16 - CAMERA; Main Menu
16 C312M-A (12/02) CAMERA For information on camera operation, refer to the manual supplied with the POD 100 thermal imager or contact Industrial SecurityAlliance Partners, Inc. at (619) 232-7041. Main Menu <Camera><Line Sync><Power Up Mode><Limit Stop><Other>EXIT Camer...
Page 17 - LIMIT STOPS; TURNING LIMIT STOPS ON OR OFF; Manual Limit Stops; Limit Stops
C312M-A (12/02) 17 LIMIT STOPS TURNING LIMIT STOPS ON OR OFF To change the limit stop mode: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Limit Stop. 3. Press the Iris Open button to enter the Limit Stop menu. 4. Position the cursor (>) beside Limit Stops....
Page 18 - Clear Manual Stops; SCAN LIMIT STOPS; Presets
18 C312M-A (12/02) Clear Manual Stops To clear the manual limit stops: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Limit Stop. 3. Press the Iris Open button to enter the Limit Stop menu. 4. Move the cursor to Clear Man Limits, and press the Iris Open button...
Page 19 - LINE SYNCHRONIZATION; Line sync; Line sync phase
C312M-A (12/02) 19 LINE SYNCHRONIZATION If cameras are out of phase with each other, they may produce what appears to be vertical roll when switching between cameras. There are two settings for line synchronization: ON – Adjust the synchronization of the power line voltage so that it is in phase wit...
Page 20 - PATTERN LENGTH; PARK TIME MINUTES
20 C312M-A (12/02) PATTERN LENGTH The ESPRIT can do the following: One full pattern – 1.5, 3, or 6 minutes long or Two half patterns – .75, 1.5, or 3 minutes long This pattern can consist of any standard pan and tilt command. Presets, flip, and turbo are not allowed in a pattern. Zone scan can beena...
Page 21 - Power Up; Exit
C312M-A (12/02) 21 POWER-UP MODE This feature lets the system resume a desired condition following power-up. The menu includes the following choices. • Default – On power-up, the system goes through a configuration cycle and stops at zero reference, showing “ConfigurationDone,” address, and mode set...
Page 22 - PROPORTIONAL PAN; Proportional pan; Park time minutes
22 C312M-A (12/02) PROPORTIONAL PAN Proportional pan does not function with this version of Esprit. Main Menu <Camera><Line Sync><Power Up Mode><Limit Stop><Other>EXIT Other Menu Proportional pan On Park time minutes 0 Scan speed deg/s 25 Pattern length 1.5 min Spd Prof...
Page 23 - SCAN SPEED; SPEED PROFILE
C312M-A (12/02) 23 SCAN SPEED The scan speed is adjustable from 1-40 degrees per second. This occurs in three scan modes: auto, random, and frame scan. To change the scan speed: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Other. 3. Press the Iris Open butto...
Page 25 - PRODUCT SUPPORT
C312M-A (12/02) 25 PRODUCT SUPPORT ES30-ISAP PAN AND TILT SYSTEM CONTACT: Pelco3500 Pelco WayClovis, CA 93612 USATel: 800/289-9100 (USA & Canada) 1-559/292-1981 (International) www.pelco.com POD 100 THERMAL IMAGER (CAMERA) CONTACT: Industrial Security Alliance Partners, Inc.1495 Pacifica Highway...
Page 26 - APPENDIX
26 C312M-A (12/02) APPENDIX NOTE: Esprit will sense and automatically select input from Coaxitron control signals in either the standard or extended mode. Therefore, the DIP switch settings have no effect on Coaxitron control signals. Table A. Switch Settings for SW1 Baud Rate Switch Setting SW1-1 S...
Page 30 - SPECIFICATIONS (PAN AND TILT SYSTEM ONLY); ELECTRICAL
30 C312M-A (12/02) SPECIFICATIONS (PAN AND TILT SYSTEM ONLY) ELECTRICAL Input Voltage: 24, 120, or 230 VAC, 50/60 Hz; switch selectable for 120/230 VAC inputs Output Voltage for POD100: 12 VDC ( ± 10%), with POD100 installed Power Consumption: Maximum 50 VA per system Electrical Connections: Two pow...
Page 31 - WARRANTY AND RETURN INFORMATION; REGULATORY NOTICES
C312M-A (12/02) 31 ® Pelco, the Pelco logo, Spectra, Genex, Legacy, Coaxitron, Esprit, and Camclosure are registered trademarks of Pelco. © Copyright 2002, Pelco. All rights reserved. REVISION HISTORY Manual # Date Comments C312M 11/02 Original version. C312M-A 12/02 Added FCC Class B information. W...