Page 3 - CONTENTS; LIST OF ILLUSTRATIONS
C1506M-A (8/02) 3 CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNINGS ..................................................................................... 4DESCRIPTION ..................................................................................................................................
Page 4 - IMPORTANT SAFEGUARDS AND WARNINGS
4 C1506M-A (8/02) 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 6. Do not install near any heat sources, such as radiators, heat registers...
Page 5 - The receiver works with standard and extended Coaxitron; MODELS; DESCRIPTION; Attach the IRD2024 to a flat surface.; Mounting Methods
C1506M-A (8/02) 5 The IRD/ERD2000 Series Receiver operates Pelco’s fixed speed pan/tilts and domes. The receiver works with standard and extended Coaxitron ® controllers, including the CM6700/ 7500/8500/9500, KBD9000, MPT9000/9008/9500, and MX4000. With Coaxitron control, pan/tiltand lens control si...
Page 6 - ERD2200 Power Connections; Input Power
6 C1506M-A (8/02) ERD2200 WIRING ENCLOSUREPOWER OUT L L N N GROUNDSTUD POWERTERMINALS MAIN POWER IN Figure 2. ERD2200 Receiver Figure 3. ERD2200 Power Connections 1. Fuses are installed for 115 VAC operation. For 230 VAC operation, install the appropriate fuses(supplied). Refer to Figure 2. 2. Set t...
Page 7 - The P/T POWER SELECT switch is set at the factory in the
C1506M-A (8/02) 7 A C A C 24V 50/60HZ INPUT POWER ~ 24V ~ 50/60HZ P/T POWER SELECT 115/230V ~ 50/60HZ A C A C ERD OPTION TLC OUT VIDEO IN PWR CX LENS AUX1 AUX2 C N N O C 24V ,1A ~ I F Z C CAM PWR C C PAN/TILT 5V CLASS 2 WIRING ERD OPTIONS 115/230V 50/60Hz .60 / .27 AMPS ~ IRD 24V 50/60Hz 1.35 AMPS ~...
Page 8 - IRD Wiring and Switch Setting
8 C1506M-A (8/02) IRD2024 WIRING 1. Connect power to the 24 VAC INPUT connector on the rear of the receiver. The receiver’s power requirement is a maximum of 5 VA, not including the camera and pan/tilt. Refer to the pan/tiltmanual for its power requirements. Do not turn on power. If necessary, refer...
Page 9 - Activate random/auto scanning by calling the following presets:; AUXILIARY OPERATION; Aux 3 operates Aux 1, and Aux 4 operates Aux 2.; OPERATION
C1506M-A (8/02) 9 When power is applied to the receiver, the green PWR LED on the receiver lights.Whenever the receiver gets a valid Coaxitron control signal, the green CX LED blinks. RANDOM/AUTO SCANNING Operation of random and auto scanning depends on whether your transmitter/controller iscommunic...
Page 10 - FUSE REPLACEMENT; Main Fuse; Enclosure Fuse; ERD2200 Wiring section for fuse location and
10 C1506M-A (8/02) FUSE REPLACEMENT CAUTION: These service instructions are for use by qualified service personnel only. To reduce the risk of electrical shock, do not perform any servicing other than that contained inthe operating instructions unless you are qualified to do so. IRD2024 Lens/Auxilia...
Page 11 - TROUBLESHOOTING; Check the wiring connections.
C1506M-A (8/02) 11 TROUBLESHOOTING Check the wiring connections. If the CX LED does not blink when commands are sent to the receiver, make sure the controller isworking properly. Also check the video coaxial cable between the controller and the VIDEO OUTconnection on the receiver. An LRD41TLC Test L...
Page 12 - WIRING TABLES; Wire Gauge; 4 VAC Wiring Distances Table; Total VA consumed; Video Coaxial Cable Requirements
12 C1506M-A (8/02) WIRING TABLES Wire Gauge Table A. 24 VAC Wiring Distances Table The following are the recommended maximum wire distances (transformer to load) for 24 VACapplications and are calculated with a 10-percent voltage drop. (Ten percent is generally themaximum allowable voltage drop for ...
Page 13 - SPECIFICATIONS
C1506M-A (8/02) 13 SPECIFICATIONS ERD2200 Electrical Input Voltage: 115/230 VAC, 50/60 HzOutput Voltage Camera: 24 VAC (or 115/230 VAC if usingenclosure power) Lens: 8 VDC Pan/Tilt: 24/115/230 VAC Enclosure: 115/230 VAC Power Consumption Receiver: 90 VA maximum, including 48 VAmaximum at 24 VAC for ...
Page 14 - REGULATORY NOTICES; • Reorient or relocate the receiving antenna.
14 C1506M-A (8/02) REGULATORY NOTICES NOTE: This equipment has been tested and found to comply with the limits of a Class B digitaldevice, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonableprotection against harmful interference in a residential installation. This ...
Page 15 - REVISION HISTORY; WARRANTY AND RETURN INFORMATION
C1506M-A (8/02) 15 REVISION HISTORY Manual # Date Comments C1506M 3/00 Original version. C1506M-A 8/02 Revised manual per ECO #02-8195 to meet UL standards. Added FCC notice. WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a peri...