Page 2 - REVISION HISTORY; CONTENTS; LIST OF ILLUSTRATIONS
2 Pelco Manual C1471M (10/98) REVISION HISTORY Manual # Date Comments C1471CM 10/98 Original version. CONTENTS Section Page 1.0 GENERAL .................................................................................................. 3 1.1 IMPORTANT SAFEGUARDS AND WARNINGS ............................
Page 3 - Only use replacement parts Pelco recommends.; The product and/or manual may bear the following marks:; RISK OF
Pelco Manual C1471M (10/98) 3 Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. 1.0 GENERAL 1.1 IMPORTANT SAFEGUARDS AND WARNINGS Observe the following WARNINGS before installing and using this product. 1. Installation and servicing shoul...
Page 4 - UNPACKING INSTRUCTIONS
4 Pelco Manual C1471M (10/98) Figure 1. System Components (In-Ceiling Model Shown) BACKBOX DOMEDRIVE LOWERDOME 1.2 UNPACKING INSTRUCTIONS This box contains one dome drive and one Installation/Operation manual (C1471M).Inspect all parts carefully. Save the shipping carton, boxes, and inserts. If an i...
Page 6 - Switch Settings for SW1; Control Type
6 Pelco Manual C1471M (10/98) 3.0 INSTALLATION 1. Turn on power to the back box. The red LED should light to indicate power. Ifthe LED does not light, correct the trouble before proceeding. (Refer to Sec-tion 6.0, TROUBLESHOOTING, in manual C1487M.) If the light operates,you may either leave power o...
Page 7 - Switch Settings for SW2 – P-Type Control; For Coaxitron; Receiver Address
Pelco Manual C1471M (10/98) 7 Table B. Switch Settings for SW2 – P-Type Control NOTE: For Coaxitron ® controls, all switches on SW2 MUST be OFF. For D-type control systems, refer to Table C. Receiver Address Switch Setting SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 1 OFF OFF OFF OFF OFF 2 ON OFF OFF OFF OFF 3 OF...
Page 8 - Switch Settings for SW2 – D-Type Control
8 Pelco Manual C1471M (10/98) Receiver Address Switch Setting SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 1 ON OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF OFF OFF 5 ON OFF ON OFF OFF OFF OFF OFF 6 OFF ON ON OFF OFF OFF OFF...
Page 13 - PAN AND TILT FUNCTIONS; The dome will stop oper-
Pelco Manual C1471M (10/98) 13 4.0 OPERATION The red LED in the back box interconnect door lights when power is turned on andthe fan exhausts heat from inside the back box. If you have an outdoor pendantmodel with a heater, heater elements in the back box turn on at 70 ° F (21 ° C) and off at 85 ° F...
Page 14 - PRESET FUNCTIONS; In the following material,
14 Pelco Manual C1471M (10/98) 4.3 ZOOM The Spectra ® Lite dome can magnify an object up to 12 times (12X of optical zoom). Zoom Telephoto - Press and hold down the Zoom Tele button until you have the picture you want. Zoom Wide - Press the Zoom Wide button to increase the field of view. 4.4 PRESET ...
Page 16 - Backlight Compensation; Sensitive
16 Pelco Manual C1471M (10/98) CM9500 1. Enter the number of the Spectra ® Lite camera and press the CAM key. 2. Press the SELECT key twice. 3. Highlight CAM in the Setup menu and press the SELECT key. 4. Highlight PRESET in the Camera menu and press the SELECT key. 5. Enter 95 and press the F1 key....
Page 20 - Manual Limit Stops; Programming preset 90
20 Pelco Manual C1471M (10/98) 3. Move the joystick up or down to cycle through the selections. Stop on the itemyou want to select. 4. SELECT – Press the Iris Open button to select your choice.CANCEL – Press the Iris Close button if you do not want to change the setting. 4.7.10 Auto Flip The two aut...
Page 21 - Scan Limit Stops; Press the Iris Open button to enter the Other submenu.; N O T E
Pelco Manual C1471M (10/98) 21 Scan Limit Stops Refer to the documentation for your control system for programming presets, thendo the following: 1. Make sure limit stops are turned ON (refer to Section 4.7.11.1), then exit themenu. 2. Push the joystick left until you reach the limit you want the ca...
Page 22 - Symptom: Unit or fan does not operate; The dome drive contains
22 Pelco Manual C1471M (10/98) 5.0 TROUBLESHOOTING Symptom: Unit or fan does not operate Refer to Section 6.0, TROUBLESHOOTING, in manual C1487M. 6.0 MAINTENANCE 6.1 DOME CLEANING Do not scratch the dome. Clean dome exterior and interior surfaces (except chromeor gold) with a nonabrasive liquid or s...
Page 24 - WARRANTY AND RETURN INFORMATION; WARRANTY; RETURNS
24 Pelco Manual C1471M (10/98) 8.0 WARRANTY AND RETURN INFORMATION Pelco, the Pelco logo, Camclosure, Esprit,Genex, Legacy, and Spectra are registeredtrademarks of Pelco.Endura and ExSite are trademarks of Pelco. © Copyright 1998, Pelco. All rights reserved. WARRANTY Pelco will repair or replace, wi...