Page 2 - CONTENTS; SECTION I: CXTA OVERVIEW
2 Pelco Manual C539M-A (12/01) CONTENTS SECTION I: CXTA OVERVIEW 1.1 DESCRIPTION .................................................................................................. 61.2 MODELS ...............................................................................................................
Page 3 - LIST OF ILLUSTRATIONS
Pelco Manual C539M-A (12/01) 3 LIST OF TABLES Table Page A Connection Disparities ....................................................................................... 7 B Signal Interface Table ........................................................................................ 22 C (TIA/EIA-...
Page 5 - IMPORTANT SAFEGUARDS AND WARNINGS; Only use replacement parts recommended by Pelco.
Pelco Manual C539M-A (12/01) 5 IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and con-form to all local codes. 2. Unless the unit is specifica...
Page 6 - CONTROL AND RECEIVER OPTION COMPATIBILITY; Equipment Control and Configuration Options
6 Pelco Manual C539M-A (12/01) NOTE: For those familiar with device attachment to 9760 systems, a convenient reference box is provided in the margin that lists the COMMS communication fileparameters for CXTA attachment to a CM9760-CC1. Refer to Section 3.3 Software Considerations , for additional in...
Page 7 - SECTION II: CXTA DEFINING CHARACTERISTICS; CONFIGURATION AND CONNECTIONS–CXTA; Fuse Replacement; CONTROLLER; D Protocol; Installation Configurations
Pelco Manual C539M-A (12/01) 7 SECTION II: CXTA DEFINING CHARACTERISTICS A number of configuration and connection decisions are made at the CXTA level in order tointerface it with one of three controllers, one of two protocol “flavors” and a large selectionof receiver options. The next section lists...
Page 8 - For the 9760, cascading is allowed addressing is no problem.; MPT; portion of section; Cascading
8 Pelco Manual C539M-A (12/01) The breakdown, with respect to cascading for each controller, is as follows: • For the 9760, cascading is allowed; addressing is no problem. • For the MPT9500, addressing 32 receivers is no problem; it is not, however very prac-tical as the controller itself is Coaxitr...
Page 9 - Configuration Switch
Pelco Manual C539M-A (12/01) 9 2.1.4 CONFIGURATION SWITCH The decode of configuration switch functions is indicated in Figure 5 and discussed in detailin the paragraphs that follow. This configuration switch configures the translator with respect to the following functions: 1. BNC Input Group (alloc...
Page 10 - Protocol Type; DIP switch position 1-4 is not used but is reserved for future use.; Unused Configuration Bit
10 Pelco Manual C539M-A (12/01) 2.1.4.2 Protocol Type This bit is set to correspond to the protocol input of the associated controller (see Figure 7). Figure 7. Protocol Type 2.1.4.3 Unused DIP Switch DIP switch position 1-4 is not used but is reserved for future use. Figure 8. Unused Configuration ...
Page 12 - SECTION III: CXTA INSTALLATION; MOUNTING THE CXTA; Rack Mounting for the CM9760-CXTA; INSTALLATION CONFIGURATIONS; A single translator hooked up in direct mode, or; You cannot cascade
12 Pelco Manual C539M-A (12/01) SECTION III: CXTA INSTALLATION 3.1 MOUNTING THE CXTA Installation of the CM9760-CXTA translator is relatively simple (refer to Figure 12). It is rackmountable in a standard 19-inch (48.26 cm) rack, using only one RU of vertical rack space.Once the unit is physically m...
Page 13 - When running the
Pelco Manual C539M-A (12/01) 13 3.2.2 9760 SYSTEM HOOKUP (P Protocol) Two possibilities are: 1. Single or multiple translators hooked to unique Sercom ports on a system matrixswitch, or 2. Item (1) with the addition of cascaded translators added to the mix. The second possibility (item 2) encompasse...
Page 14 - Installation Decision Tree
14 Pelco Manual C539M-A (12/01) Flowchart 1. Installation Decision Tree The following flowchart might prove helpful as an aide in configuring the different systems mentioned above with CXTA translator(s).The flowchart does not include direct mode using the CM9760-KBD.
Page 15 - Direct Mode Installation
Pelco Manual C539M-A (12/01) 15 Figure 13. Direct Mode Installation
Page 19 - SOFTWARE CONSIDERATIONS; COMMS File Example for the CXTA
Pelco Manual C539M-A (12/01) 19 3.3 SOFTWARE CONSIDERATIONS Despite the considerations given in this section to highlight aspects of required softwaresetup, there is no substitute for consulting the respective manuals for both the controllerchosen and for the receiver to be used. You must take care ...
Page 20 - Control/Serial Port Speeds; CAMERA Files Example for the CXTA; Keyboard; portion
20 Pelco Manual C539M-A (12/01) 3.3.2 CM9760-KBD DIRECT MODE Consult the required manuals for setting up direct mode operation. The KBD manual(C540M) is the most important. In particular, see section 3.2.7 Direct Camera Control/Serial Port Speeds in the KBD manual. 3.3.3 MPT9500 TRANSMITTER/CONTROLL...
Page 21 - SECTION IV: CXTA OPERATION; COMMAND SET VARIATION
Pelco Manual C539M-A (12/01) 21 SECTION IV: CXTA OPERATION 4.1 POWER-UP At power up, the system microcontroller reads the configuration switch, dip switch posi-tions, sets up the internal UART with the requested baud rate and stores the configurationsettings in internal RAM. Subsequent protocol-spec...
Page 22 - COMMUNICATION PARAMETERS; Signal Interface Table; Device A; TX –
22 Pelco Manual C539M-A (12/01) SECTION V: APPENDIX 5.1 COMMUNICATION PARAMETERS There is only one basic set of signal interface rules that you must consider when wiring two9760 communication devices together. Those rules are given in step 3 below. Frustration arises only if the information you are ...
Page 23 - Cable Identification
Pelco Manual C539M-A (12/01) 23 If a cable is “straight”, then pin 1 at one end of the cable goes to pin 1 at the opposite endof the cable. If the connecting plugs on this cable interface two devices, then pin 1 on de-vice one would physically be connected to pin 1 on device two. Straight cable is u...
Page 24 - Data Rate vs. Cable Length
24 Pelco Manual C539M-A (12/01) 5.2 CABLE PARAMETERS Data communication cables are used in the CM9760 system to connect required equipment toappropriate data communication ports on the CC1, which are either RS-232 or RS-422 driven. The characteristics of the cable chosen (if not supplied) depends, f...
Page 27 - PRODUCT WARRANTY AND RETURN INFORMATION
Pelco Manual C539M-A (12/01) 27 SECTION VI: GENERAL 6.1 SPECIFICATIONS ELECTRICAL Input Voltage: 100-240 VAC, 50/60 Hz, auto-ranging PowerConsumption: 15VA Coaxitron Ports Video Format: NTSC or PAL Video Level: ± 6dB minimum CoaxitronLevel: 0.7 V peak Data PortsInput: RS-422, 8-pin, 4-wire, RJ-45 co...
Page 28 - REVISION HISTORY; REGULATORY NOTICES; Reorient or relocate the receiving antenna.
28 Pelco Manual C539M-A (12/01) REVISION HISTORY Manual # Date Comments C539M 1/98 Original version. 8/01 Baud reference correction. C539M-A 12/01 Completely revised and updated to include added protocols, and appendix. 6.2 REGULATORY NOTICES This equipment has been tested and found to comply with t...