Page 3 - Description; compatible and can be placed on a desktop or rack; MODELS
C808M-G (4/05) 3 Description The VS5004 and VS5008 sequential switchers are designed to switch up to four (VS5004) or eight (VS5008) cameras manually or automatically to one or two monitors with automatic response to alarm inputs. Both versions are Coaxitron ® compatible and can be placed on a deskt...
Page 4 - Installation; TERMINATED CAMERA INPUTS AND ONE MONITOR OUTPUT; be terminated with a 75-ohm BNC terminator.
4 C808M-G (4/05) Installation TERMINATED CAMERA INPUTS AND ONE MONITOR OUTPUT 1. Make all equipment connections. Refer to Figure 1 (VS5004) or Figure 2 (VS5008). VS5008 only: When configured for one-monitor operation, the monitor must be connected to the MON 2 output. The MON 1 output must be termin...
Page 5 - REAR VIEW
C808M-G (4/05) 5 Figure 2. VS5008 Terminated Camera Inputs - One Monitor Figure 3. VS5004 Alarm Connections VS5008 (REAR) MON 1 MON 2 MON X CAMERAS 8 7 6 5 4 3 2 1 12 VAC INPUT ALARM INPUT COM ALARM OUT 1 2 3 4 5 6 7 8 NOTE: MON 1 MUST BE TERMINATED. MON 1 MON 2 1 2 3 4 1 2 3 4 ALARM 12VACINPUT IN 1...
Page 7 - LOOPING CAMERA INPUTS AND ONE MONITOR OUTPUT; Looping and terminated inputs may be mixed.
C808M-G (4/05) 7 LOOPING CAMERA INPUTS AND ONE MONITOR OUTPUT 1. Convert the switcher to looping operation. Refer to Figure 5 and do the following: NOTE: Looping and terminated inputs may be mixed. a. Remove the cover. b. Remove the rear panel of the chassis. c. Locate the 75-ohm resistors located o...
Page 9 - VS5008 Looping Camera Inputs - One Monitor; TERMINATED CAMERA INPUTS AND TWO MONITOR OUTPUTS; Remove the rear panel of the chassis.; IN THIS CONFIGURATION,
C808M-G (4/05) 9 Figure 7. VS5008 Looping Camera Inputs - One Monitor TERMINATED CAMERA INPUTS AND TWO MONITOR OUTPUTS 1. Convert the VS5004 to dual-monitor operation. Refer to Figure 8 and do the following: a. Remove the cover. b. Remove the rear panel of the chassis. c. Remove the four screws atta...
Page 12 - LOOPING CAMERA INPUTS AND TWO MONITOR OUTPUTS
12 C808M-G (4/05) LOOPING CAMERA INPUTS AND TWO MONITOR OUTPUTS 1. Convert the VS5004 to dual-monitor operation. Refer to Figure 8 and do the following: a. Remove the cover. b. Remove the rear panel of the chassis. c. Remove the four screws attaching the PC board to the chassis. d. Pull the PC board...
Page 13 - In this configuration
C808M-G (4/05) 13 7. Connect the AC adapter to the 12 VAC input plug on the rear of the VS5004 or VS5008. Connect the transformer to a 120 VAC (VS5004 or VS5008) or 230 VAC (VS5004/220 or VS5008/220) power source. After power up, the switcher will begin sequencing. 8. Using a screwdriver, adjust the...
Page 14 - COAXITRON CONTROL
14 C808M-G (4/05) COAXITRON CONTROL To convert for use with a Coaxitron transmitter, do the following: 1. Convert the VS5004 to dual-monitor operation. Refer to Figure 8 and do the following: a. Remove the cover. b. Remove the rear panel of the chassis. c. Remove the four screws attaching the PC boa...
Page 15 - should have their channel switch set to the BYPASS position.
C808M-G (4/05) 15 6. For channels with cameras connected to the video inputs, set the front panel switches to the AUTO position. All unconnected video inputs should have their channel switch set to the BYPASS position. NOTES: • VS5004 and VS5008 with one-monitor configuration: All channels with a sw...
Page 17 - Specifications; VIDEO
C808M-G (4/05) 17 Specifications VIDEO Inputs Terminating (75 ohms) or looping Outputs Monitor 1 75 ohms Monitor 2 VS5004 Hi Z VS5008 75 ohms Monitor X VS5008 Coaxitron transmitter (nonamplified) output Gain Unity Dwell Adjustable from 1-70 seconds nominal Frequency Response Flat within +/-1 dB to 1...
Page 19 - PRODUCT WARRANTY AND RETURN INFORMATION
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material orworkmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic ...