Page 3 - Important Safety Instructions; it must not be installed where exposed to rain and moisture.
C3401M-A (1/06) 3 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 6. Do not install near any heat sources such...
Page 4 - Regulatory Notices; RADIO AND TELEVISION INTERFERENCE; Reorient or relocate the receiving antenna.
4 C3401M-A (1/06) Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesire...
Page 5 - Description; The Spectra; MODELS
C3401M-A (1/06) 5 Description The Spectra ® Mini is an indoor dome system designed for ceiling applications. The dome can be mounted to the surface of ceilings, or it can be recessed in hard ceilings or standard 2 x 2 ft (61 x 61 cm) tiles in suspended ceilings. The Spectra Mini includes a high reso...
Page 6 - Installation; Package Components
6 C3401M-A (1/06) Installation The following parts are supplied with the Spectra Mini dome system: 1 Dome drive 1 Dome bubble with trim ring 1 Interface cable with a male RJ45-10 connector on one end and four twisted wire pairs on the other end 1 Cover for use with optional translator board 2 #10 x ...
Page 7 - SWITCH SETTINGS; The unit automatically detects D or P protocal.; DATA PORT; Software/Language File Upload
C3401M-A (1/06) 7 SWITCH SETTINGS Coaxitron control: If you are going to use Coaxitron protocol to communicate with the dome system, you do not have to set any switches. Proceed to the installation instructions that follow this section. Non-Pelco control: If you are going to install a protocol trans...
Page 8 - Switch Settings for SW2; Special Systems; Baud Rate; Switch Number; Protocol Termination; Switch Number
8 C3401M-A (1/06) *If you are connecting a single dome to a controller, terminate the dome. When connecting more than one dome to a single controller, terminate the dome farthest from the controller. Table A. Switch Settings for SW2 Special Systems Switch Number SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 S...
Page 16 - SURFACE MOUNT INSTALLATION; Dome with translator board:; Connect the wiring and attach the dome drive to the ceiling.
16 C3401M-A (1/06) SURFACE MOUNT INSTALLATION 1. On top of the dome drive is an opening for an optional translator board. The opening has a cover that must be left in place if a translator board is not required. A taller cover is supplied if a translator board is installed. If you are going to insta...
Page 18 - Wiring Distances; Voltage; Interface Cable Wiring; Pin Color; Video Coaxial Cable Requirements; Maximum Distance
18 C3401M-A (1/06) Table F. Wiring Distances The following are the recommended maximum distances for 24 VAC applications and are calculated with a 10 percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC-powered devices. NOTE: Power consumption is 21 VA per unit. ...
Page 19 - RECESSED INSTALLATION; SUSPENDED CEILING; Remove the ceiling tile from the ceiling.; Using the supplied interface cable:; Replace the ceiling tile.
C3401M-A (1/06) 19 RECESSED INSTALLATION SUSPENDED CEILING 1. On top of the dome drive is an opening for an optional translator board. The opening has a cover that must be left in place if a translator board is not required. A taller cover is supplied if a translator board is installed. If you are g...
Page 21 - Ceiling Tile Installation
C3401M-A (1/06) 21 Figure 8. Ceiling Tile Installation 6. Line up the tabs on the trim ring with the slots in the dome drive. Snap the trim ring and dome bubble into place. SURFACE MOUNT RING #10 x 1.50-INCHSELF-TAPPINGSCREWS(SUPPLIED) DOME DRIVE CEILING TILE
Page 22 - HARD CEILING; Lift and remove the surface mount ring from the dome drive.
22 C3401M-A (1/06) HARD CEILING 1. On top of the dome drive is an opening for an optional translator board. The opening has a cover that must be left in place if a translator board is not required. A taller cover is supplied if a translator board is installed. If you are going to install a translato...
Page 23 - In-Ceiling Installation to a Fixed Ceiling
C3401M-A (1/06) 23 5. Attach the dome drive to the ceiling with the two 3-16 toggle bolts (not supplied). Refer to Figure 9. Figure 9. In-Ceiling Installation to a Fixed Ceiling 6. Line up the tabs on the trim ring with the slots in the dome drive. Snap the trim ring and bubble into place. WARNING: ...
Page 24 - Specifications; MECHANICAL
24 C3401M-A (1/06) Specifications MECHANICAL Pan Movement 360° continuous pan rotation Vertical Tilt Unobstructed +2° to -92° Manual Pan/Tilt Speeds Pan 0.4-80°/sec manual operation, 100°/sec turbo Tilt 0.7-40°/sec manual operation Preset Speeds Pan 140°/sec Tilt 80°/secFor variable speed operation ...
Page 25 - LENS; WITH TXB TRANSLATOR BOARD
C3401M-A (1/06) 25 Horizontal Resolution NTSC >470 TV lines PAL >460 TV lines Minimum Illumination 3.0 lux Sync System AC line lock, phase adjustable via remote control, V-Sync White Balance Automatic with manual override Shutter Speed Automatic (electronic iris)/manual1/60~1/30,000 Gain Contr...
Page 27 - RETURNS
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanshi p for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber opti...