Page 4 - IMPORTANT SAFETY INSTRUCTIONS
[ 4 ] Pelco Manual C2913M-F (08/05) This symbol indicates that dangerous voltageconstituting a risk of electric shock is presentwithin this unit. This symbol indicates that there are impor-tant operating and maintenance instructionsin the literature accompanying this unit. Please thoroughly familiar...
Page 5 - REGULATORY NOTICES; Reorient or relocate the receiving antenna.; DESCRIPTION; Models
Pelco Manual C2913M-F (08/05) [ 5 ] REGULATORY NOTICES This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) thisdevice may not cause harmful interference, and (2) this device must accept any interference received, includinginterference that ma...
Page 6 - INSTALLATION; Lens Mounting; Auto Iris Lens Only -; PIN; Not used; CAMERA LAYOUT; Figure 1. Camera Layout; Camera Connector
[ 6 ] Pelco Manual C2913M-F (08/05) INSTALLATION Lens Mounting MC3610 and MC3710 Series cameras can use fixed iris, manual iris, auto iris, or direct drive lenses. Camerasare factory-set for CS-mount lenses, but are easily adjusted for C-mount lenses. 1. C-Mount Lens Only - Loosen the two back focus...
Page 7 - Camera Mounting; times the combined weight of the camera and lens.; Figure 3. Camera Mounting; CONNECTIONS; Video Connections; BNC connector to the BNC; Table A. Video Coaxial Cable Requirements
Pelco Manual C2913M-F (08/05) [ 7 ] Camera Mounting Mounting points are provided on the top and bottom of the camera and are used to mount the camera on abracket or tripod. They are designed to accept standard photographic mounting bolts (1/4-inch UNC-20). Themounting bracket must be capable of supp...
Page 8 - Power Connections; Mains Power Supply
[ 8 ] Pelco Manual C2913M-F (08/05) Power Connections MC3610 and MC3710 Series cameras are available in AC high voltage and AC/DC low voltage types. Thevoltage required to operate the camera is clearly marked on the rear panel of the camera. The green POWERLED on the rear panel indicates that power ...
Page 9 - a minimum wire gauge of 24 AWG.
Pelco Manual C2913M-F (08/05) [ 9 ] EXAMPLE: A camera that requires 5 VA and is installed 224 feet (68 m) from the transformer would require a minimum wire gauge of 24 AWG. Table B. Wiring Distances for 5 VA Cameras (24 VAC/12 VDC) The following are the recommended maximum distances for low voltage ...
Page 12 - Ser vice Connection; Figure 6. Service Connector; the rear panel of the camera.; 4 VAC/12 VDC Power Connection
[ 12 ] Pelco Manual C2913M-F (08/05) Ser vice Connection The service connector allows a video monitor to be connected locally to the camera using a 2.5 mm plug tocomposite video BNC cable. Figure 6. Service Connector NOTE: Inserting the plug into the service connector disconnects video from the comp...
Page 13 - CAMERA SETUP; Lens Setup and Focus Procedures; Video Drive or Direct Drive (DC) Auto Iris Lens; Remove the ND filter and set the lens focus as required.; Fixed Lens; sensitivity, the smallest aperture the greatest depth of field.; Zoom Lens; For best results outdoors use an ND3 (neutral density) filter.
Pelco Manual C2913M-F (08/05) [ 13 ] CAMERA SETUP Lens Setup and Focus Procedures Video Drive or Direct Drive (DC) Auto Iris Lens 1. Set the ESC switch and AGC switch to OFF.2. Adjust the lens for the optimum picture. Video Drive. Refer to the lens instructions and adjust the lens for the optimum pi...
Page 14 - Back Focus Adjustment; To adjust the back focus:; Figure 8. Back Focus Adjustment
[ 14 ] Pelco Manual C2913M-F (08/05) Back Focus Adjustment The back focus adjustment is located at the front of the camera and is accessible from either side of the case. To adjust the back focus: 1. Loosen the two back focus locking screws (one on each side). 2. Turn the back focus ring countercloc...
Page 15 - Figure 9. Switch Settings; Switch Settings; before making any adjustments.; - Enables the Electronic Shutter Control mode.; Switch Setting 3
Pelco Manual C2913M-F (08/05) [ 15 ] Figure 9. Switch Settings (White indicates default switch position.) Switch Settings NOTE: Under most conditions, no setting of switches will be required. Please read the details of each switch before making any adjustments. AGC (Automatic Gain Control) - Switch ...
Page 16 - termination DIP switch needs to be set to 75
[ 16 ] Pelco Manual C2913M-F (08/05) Flickerless - Switch Setting 4 The flickerless setting can reduce the flicker caused by certain lighting conditions. TheElectronic Shutter Control must be off for the correct operation of the flickerless function.Choose between the following settings:ON - Enables...
Page 17 - Camera Synchronization; To line lock the cameras, do the following:
Pelco Manual C2913M-F (08/05) [ 17 ] Camera Synchronization When using more than one camera power supply, a brief vertical roll may occur on the monitor when a cameraview is switched. To eliminate this vertical roll, it is necessary for the cameras to be synchronized. If thecameras are connected to ...
Page 18 - SPECIFICATIONS; GENERAL
[ 18 ] Pelco Manual C2913M-F (08/05) SPECIFICATIONS GENERAL Imaging Device: 1/3-inch interline transfer CCD Picture Elements MC3710H and MC3610H: EIA 768 (H) x 494 (V); CCIR 752 (H) x 582 (V) MC3710S: EIA 510 (H) x 492 (V); CCIR 500 (H) x 582 (V) Sensing Area: 6 mm diagonal Scanning System EIA: 525 ...
Page 23 - Date
Pelco Manual C2913M-F (08/05) [ 23 ] REVISION HISTORY Manual # Date Comments C2913M 05/04 Original version. C2913M-A 0 7/04 Lens connector pin out changed. C2913M-B 09/04 Clarified instructions for UTP use. C2913M-C 11/04 Added UL warning for high-voltage models. C2913M-D 11/04 Revised safety instru...