Page 2 - CONTENTS; Section; LIST OF ILLUSTRATIONS; Figure
CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNINGS ..................................................................................... 3 WELCOME .......................................................................................................................................... 4 MODELS ...
Page 3 - IMPORTANT SAFEGUARDS AND WARNINGS
IMPORTANT SAFEGUARDS AND WARNINGS 1. Installation and servicing should be done only by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and must not be install...
Page 4 - WELCOME; MODELS
WELCOME Thank you for purchasing Pelco’s ICS090 Series Camclosure ® housing for indoor applications. The unit is easy to install and can be mounted to the surface of a ceiling/wall or recessed in a ceiling/ wall. The following is supplied with the ICS090 Series housing: Qty. Description 1 Assembled ...
Page 5 - REMOVE THE BUBBLE; How to Remove the Bubble
REMOVE THE BUBBLE Turn the bubble counterclockwise and lift (refer to Figure 1). Place the bubble on a nonabrasive surface. Figure 1. How to Remove the Bubble C2477M (6/03) 5
Page 6 - INSTALL THE BACK BOX; INSTALLATION TO SURFACE OF A CEILING/WALL; Ceiling/Wall Installation
INSTALL THE BACK BOX The installation methods for the ICS090 Series housing include the following: • Mount to the surface of a ceiling/wall • Install in a suspended ceiling • Install in a fixed ceiling/wall Select the best method for your installation and refer to the following pages for instruction...
Page 7 - IN-CEILING INSTALLATION – SUSPENDED CEILING; Refer to Figure 4 for the following steps.; Ceiling Tile Installation; How to Remove Surface Mount Ring from Back Box
IN-CEILING INSTALLATION – SUSPENDED CEILING Refer to Figure 4 for the following steps. 1. Remove the ceiling tile from the ceiling. 2. Cut a four-inch diameter hole in the ceiling tile. 3. Remove the surface mount ring from the back box. Refer to Figure 5 and do the following: a. Place fingers on th...
Page 8 - IN-CEILING INSTALLATION – FIXED CEILING/WALL; Refer to Figure 6 for the following steps.
IN-CEILING INSTALLATION – FIXED CEILING/WALL Refer to Figure 6 for the following steps. 1. Cut a four-inch diameter hole in the ceiling/wall. 2. Remove the surface mount ring from the back box. Refer to Figure 5 and do the following: a. Place fingers on the circular marks located on the sides of the...
Page 9 - REINSTALL THE BUBBLE; To install the bubble refer to Figure 7 and do the following:
REINSTALL THE BUBBLE To install the bubble refer to Figure 7 and do the following: 1. Align the standoffs of the bubble with the slots of the back box. 2. Turn the bubble clockwise until it locks in place. Figure 7. How to Install the Bubble C2477M (6/03) 9
Page 10 - SPECIFICATIONS; General; Construction
SPECIFICATIONS General Construction Back Box and Surface Mount Ring: ABS plastic Bubble: Polycarbonate Finish: White Environment: Indoor Weight Unit: .52 lb (.24 kg) Shipping: 2 lb (.91 kg) (Design and product specifications subject to change without notice.) 5.30 (13.46) 1.65 (4.19) 4.04 (10.26) 2....
Page 11 - WARRANTY AND RETURN INFORMATION
WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on Pelco manufactured cameras (CC3500/C...