Page 2 - IMPORTANT SAFEGUARDS AND WARNINGS; Only use replacement parts recommended by Pelco.
2 Pelco Manual C2434M (7/01) IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel andconform to all local codes. 2. Unless the unit is specifically ...
Page 3 - DESCRIPTION; SYSTEM MODELS; System Model; DD5BCBW
Pelco Manual C2434M (7/01) 3 DESCRIPTION The Heavy-Duty Spectra is perfect for installations where structural integrity and vandalismare a priority. The system features heavy-duty construction and tamper-resistant barrel keylocks. The in-ceiling model has a reinforced bracket mounting system for ins...
Page 4 - INSTALLATION OF IN-CEILING MODEL; STEP 1 - PREPARE CEILING
4 Pelco Manual C2434M (7/01) 00535 SPRING CLIP 8-32X.275 INCH SCREW 00537 00530 00531 00532 CEILING MOUNTINGRING S 00533 ATTACH SAFETY CHAIN HERE 00534 INSTALLATION OF IN-CEILING MODEL STEP 1 - PREPARE CEILING a. Locate the center point of the mount- ing location. Drill a hole in the ceilingusing a ...
Page 5 - TO USE YOUR DOME, REFER TO THE OPERATION AND; STEP 4 - WIRE CIRCUIT BOARD; b. Insert both keys in the barrel locks. Turn keys clockwise to the
Pelco Manual C2434M (7/01) 5 LABEL SW1 LABEL SW2 SW1 SW2 RS-422 TERMINATION SWITCH ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 SW2 00538 GREEN TAB RED TAB 00539 BARRELKEY LOCK BALL STUDRECEIVER BALL STUD 00497 TRIM LEASH TO USE YOUR DOME, REFER TO THE OPERATION AND PROGRAMMING MANUAL. +5 to +24 VDC NOT US...
Page 6 - INSTALLATION OF PENDANT MODELS; STEP 1 - DISASSEMBLE BACK BOX; Appendix for wiring distances.
6 Pelco Manual C2434M (7/01) INSTALLATION OF PENDANT MODELS STEP 1 - DISASSEMBLE BACK BOX a. Turn the thumbscrew and open the hinged door locatedinside the back box. 01082 01081 01080 b. Unscrew the three Phillips screws located underneath thehinged door. Remove the inside portion of the back box. c...
Page 7 - If the LED does not light, refer to the
Pelco Manual C2434M (7/01) 7 STEP 3 - INSTALL THE BACK BOX 01079 01078 a. Secure the conduit fitting to the hole located on the insidebase of the octagonal back box. b. Pull the cable and wiring for the system through theoctagonal back box and conduit fitting. Mount the backbox to the mounting surfa...
Page 8 - STEP 5 - INSTALL DOME DRIVE; Appendix in the back of this manual.; STEP 6 - INSTALL LOWER DOME
8 Pelco Manual C2434M (7/01) STEP 5 - INSTALL DOME DRIVE LABEL SW1 LABEL SW2 SW1 SW2 RS-422 TERMINATION SWITCH ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 SW2 00538 a. Set the DIP switches for SW1 and SW2 on the bottom ofthe dome drive for the appropriate receiver address. Referto the labels on the dome d...
Page 9 - TROUBLESHOOTING
Pelco Manual C2434M (7/01) 9 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Unit does not operate.The controller is notcommunicating withthe Spectra unit. Fan does notoperate. Vertical roll on monitorwhen switchingbetween cameras. DOME 1POWER DOME 2POWER DOME 3POWER Check to see if the red LED on t...
Page 10 - APPENDIX; Video Coaxial Cable Requirements
10 Pelco Manual C2434M (7/01) APPENDIX Table A. Video Coaxial Cable Requirements Cable Type* Maximum Distance RG59/U 750 ft (229 m) RG6/U 1,000 ft (305 m) RG11/U 1,500 ft (457 m) * Minimum cable requirements: 75 ohms impedance. All-copper center conductor.95% braided copper shield. Table B. 24 VAC W...
Page 14 - SPECIFICATIONS; MECHANICAL
14 Pelco Manual C2434M (7/01) SPECIFICATIONS MECHANICAL Construction Back box: Aluminum Dome drive: Aluminum, ABS plastic Lower dome: Acrylic Cable Entry In-Ceiling: .75-inch (1.91 cm) conduit fitting Pendant: Through 1.5-inch (3.81 cm) NPT pendant mount Pan Movement: 360 ° continuous pan rotation V...
Page 15 - GENERAL; Indoor only; Dimension Diagram
Pelco Manual C2434M (7/01) 15 GENERAL EnvironmentIn-Ceiling: Indoor only Pendant: Indoor/outdoor Operating Range In-Ceiling: 32 to 122 ° F (0 to 50 ° C) Pendant: (Assumes no wind chill factor; for detailed test conditions,contact Pelco) Maximum: 140 ° F (60 ° C) absolute maximum 122 ° F (50 ° C) sus...
Page 16 - REVISION HISTORY; Date; PRODUCT WARRANTY AND RETURN INFORMATION
16 Pelco Manual C2434M (7/01) REVISION HISTORY Manual # Date Comments C2434M 7/01 Original version. Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco. © Copyright 2001, Pelco. Endura and ExSite are trademarks of Pelco. All rights reserved. PRODU...