Page 2 - IMPORTANT SAFEGUARDS AND WARNINGS
[ 2 ] Pelco Manual C1506M (3/00) Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, ...
Page 3 - DESCRIPTION; The receiver works with standard and extended Coaxitron; Models; MOUNTING; Attach the IRD2024 to a flat surface.
Pelco Manual C1506M (3/00) [ 3 ] DESCRIPTION The IRD/ERD2000 Series Receiver operates Pelco’s fixed speed pan/tilts and domes. The receiver works with standard and extended Coaxitron ® controllers, including the CM6700/7500/8500/ 9500, KBD9000, MPT9000/9008/9500, and MX4000. With Coaxitron control, ...
Page 4 - Fuses are installed for 115 VAC operation.; Input Power
[ 4 ] Pelco Manual C1506M (3/00) ERD2200 WIRING ERD2200 Power Connections ENCLOSUREPOWER OUT L L N N 115V 230V 1 15V POWERSELECTORSWITCH GROUNDSTUD POWERTERMINALS MAINFUSE ENCLOSURE FUSE MAIN POWER IN 1. Fuses are installed for 115 VAC operation. For 230 VAC operation, install the appropriatefuses (...
Page 5 - Wiring Tables; Front View of Receiver; Rear View of Receiver
Pelco Manual C1506M (3/00) [ 5 ] 6. Connect the pan/tilt controls (up, down, left, right, and common). 7. Connect the camera power. If your camera uses 24 VAC, connect the camera to the CAM PWR connector on the front of the re-ceiver. The camera’s power must not exceed 5 vA. If your camera uses 115 ...
Page 7 - OPERATION; Auxiliary Operation; Standard Coaxitron; Optional Latching Mode (Extended Coaxitron Only); – When a valid
Pelco Manual C1506M (3/00) [ 7 ] OPERATION When power is applied to the receiver, the green PWR LED on the receiver lights. Whenever the receiver gets a valid Coaxitron control signal, the green CX LED blinks. Random/Auto Scanning Operation of random and auto scanning depends on whether your transmi...
Page 8 - FUSE REPLACEMENT; Lens/Auxiliary Fuse –; TROUBLESHOOTING
[ 8 ] Pelco Manual C1506M (3/00) FUSE REPLACEMENT IRD2024 Lens/Auxiliary Fuse – A 500 mA fuse protects the LENS and AUX 1 outputs. Remove the cover of the receiver to check the fuse. ERD2200 Main Fuse – The main fuse protects the pan/tilt output when 24 VAC pan/tilt operation is selected. It also pr...
Page 9 - Wire Gauge; Table A; 4 VAC Wiring Distances Table; Total vA consumed; Video Coaxial Wiring Distances; Maximum Distance; would require a minimum wire gauge of 20 AWG.; WIRING TABLES
Pelco Manual C1506M (3/00) [ 9 ] Wire Gauge Table A 24 VAC Wiring Distances Table The following are the recommended maximum wire distances (transformer to load) for 24 VAC applica-tions and are calculated with a 10-percent voltage drop. (Ten percent is generally the maximum allowablevoltage drop for...
Page 10 - SPECIFICATIONS
[ 10 ] Pelco Manual C1506M (3/00) SPECIFICATIONS ERD2200 ELECTRICAL Input Voltage: 115/230 VAC, 50/60 HzOutput Voltage Camera: 24 VAC (or 115/230 VAC if usingenclosure power) Lens: 8 VDC Pan/Tilt: 24/115/230 VAC Enclosure: 115/230 VAC Power Consumption Receiver: 5 vA maximum Pan/Tilt andCamera: 48 v...
Page 12 - WARRANTY AND RETURN INFORMATION; REVISION HISTORY
WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after thedate of shipment. Exceptions to this warranty are as noted below: • Three years on Genex ® Series (multiplexers, server, and keyboard). • Two years on ...