TABLE OF CONTENTS Section Page 1.0 WARNINGS ....................................................................................................................................... 1 2.0 SCOPE ...............................................................................................................
Page 3 - iii
LIST OF ILLUSTRATIONS Figure Page 1 TYPICAL ICI3000P SYSTEM USED WITH STAND-ALONE CAMERAS .............................................. 2 2 ICI3000P PARTYLINE WIRING CONFIGURATION .............................................................................. 4 3 DEFAULTING INTER-CHECK SYSTEM. ........
Page 4 - iv
iv Pelco Manual C1043M-A (2/96) (This page intentionally left blank.)
Page 5 - SALE MONITORING SYSTEM; prior to installation and operation.; literature accompanying this unit.; RISK OF ELECTRIC SHOCK.; CAUTION
Pelco Manual C1043M-A (2/96) 1 INSTALLATION/OPERATION MANUALICI3000P INTER-CHECK ® POINT-OF- SALE MONITORING SYSTEM Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. This symbol indicates that there are importantoperating and maintenance ...
Page 6 - Figure 1. Typical ICI3000P System with Fixed Cameras
2 Pelco Manual C1043M-A (2/96) 2.0 SCOPE The information contained within this manual coversthe installation and operation of the Inter-CheckICI3000P cash register interface system. Installationshould be in accordance with all applicable local andnational electric codes, using approved materials onl...
Page 7 - CALCULATED CRC = ZZZZ; ENT
Pelco Manual C1043M-A (2/96) 3 3.0 INSTALLATION 3.1 SETTING UP ICI1000PIM PARAMETERS AND BENCH TESTING NOTE: Please familiarize yourself with the information in this manual prior to installationand operation. Contact the customer's registerdealer/installer prior to installation and opera-tion. Some ...
Page 8 - : Do not power up the ICI3000P unit; NOTE; DO NOT; Connect the Shield on the ICI3000P end of the loop.
4 Pelco Manual C1043M-A (2/96) D I P S WI T C H D E S C R I P T I O N - - S w i t c h # F u n c t i o n 1 2 3 4 B a n k a d d r e s s B a n k a d d r e s s B a n k a d d r e s s B a n k a d d r e s s 5 6 7 8 l o o p b a u d r a t e N C N C 1 2 3 4 5 6 7 8 OPE N 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 6 1 5 ...
Page 9 - Refer to Figure 1 for a typical ICI3000P configuration.; ENTER; approximately 3 seconds.
Pelco Manual C1043M-A (2/96) 5 3.3 ICI3008/ICI3016 INSTALLATION Refer to Figure 1 for a typical ICI3000P configuration. 1. Connect the 9-pin switcher interface cable (suppliedwith the ICI3008/ICI3016 switcher) into the portlabeled “RS 232” of the ICI3000P. 2. Connect the modular phone plug of the sw...
Page 10 - Shadow switchers are available in either 8 or 16 positions.; NOTE: Cover must be removed to access this dip switch.
6 Pelco Manual C1043M-A (2/96) D I P S WI T C H D E S C R I P T I O N - - S w i t c h # F u n c t i o n 1 2 3 4 B a n k a d d r e s s B a n k a d d r e s s B a n k a d d r e s s B a n k a d d r e s s 5 6 7 8 l o o p b a u d r a t e N C N C 1 2 3 4 5 6 7 8 OPE N 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 6 1 5 ...
Page 12 - H I V
8 Pelco Manual C1043M-A (2/96) 3.4 EXTERNAL VIDEO ADJUSTMENTS There are five potentiometer adjustments located on thebottom of the Inter-Check unit. These video text ad-justments are for fine tuning only. Major adjustmentsshould be done through the operating software. Use asmall tipped, nonmetallic ...
Page 13 - Figure 7. Inter-Check’s Two Text Screens; SELECT MENU
Pelco Manual C1043M-A (2/96) 9 Figure 7. Inter-Check’s Two Text Screens S C R E E N # 1 O R T E X T W I N D O W # 1 S C R E E N # O R T E X T WI N D O W # 2 2 P E L C O 4.0 PROGRAMMING To enter the SELECT MENU press enter. The followingmenu will be displayed on monitor: SELECT MENU 1. Register # 1 o...
Page 17 - — Not Applicable; Group Poll List
Pelco Manual C1043M-A (2/96) 13 4.8.6 Channel Program Menu 4.8.6.1 Partyline Press [ 6 ]. The following prompt will be displayed: CHANNEL PROGRAM MENU 4. Group Poll List5. Exception Follow Alarm Time6. Group Select 4.8.6.2 Channel Program Menu 1. Baud Rate — Not Applicable 2. RS-232 — Not Applicable...
Page 20 - : Exceptions can only be displayed on; EXCEPTIONS MENU
16 Pelco Manual C1043M-A (2/96) 4.9 EXCEPTIONS Exceptions are cash register transactions of special interestthat can be programmed into the ICI3000P units. Typicaltransactions are VOID, REFUND, CASH PAID OUT andNO SALE. These types of transactions can then be usedto alarm your VCR or other alarmable...
Page 22 - “Negative”
18 Pelco Manual C1043M-A (2/96) 4.9.3 Exceptions Using the Price Point Editing Strategy This type of exception is used to program an exceptionthat is looking for characteristics in the actual price of theitem, rather than a specific word. The keyboard characterused in this type of exception strategy...
Page 28 - Enter; video ON if the monitor is blank by pressing [
24 Pelco Manual C1043M-A (2/96) 8.0 POWER-UP PROCEDURE FOR THE ICI3000P In the event of a power failure, the Inter-Check Systemhas a nonvolatile memory and will retain all memorythat has been previously saved. Some program func-tions, in order to be used, will have to be activated us-ing the hot key...
Page 30 - OUTPUT DEFINITIONS
26 Pelco Manual C1043M-A (2/96) 9.1 OUTPUT DEFINITIONS WIRE COLOR PIN DESIGNATION DESCRIPTION White 1 +5 volts (For testing only) Black 2 Signal Ground Red 3 RS232 Current Loop CHANNEL 1 INPUT Green 4 NOT USED Yellow 5 (Opto y-jack input) ICI1000PIM Input for CHANNEL 1 Blue 6 NOT USED AUXILIARY PORT...
Page 31 - WARRANTY; RETURNS
Pelco Manual C1043M-A (2/96) 27 10.0 WARRANTY AND RETURN INFORMATION Pelco, the Pelco logo, Camclosure, Esprit,Genex, Legacy, and Spectra are registeredtrademarks of Pelco.Endura and ExSite are trademarks of Pelco. © Copyright 1996, Pelco. All rights reserved. WARRANTY Pelco will repair or replace, ...
Page 32 - PELCO; (Product specifications subject to change
28 Pelco Manual C1043M-A (2/96) PELCO 3500 Pelco Way Clovis, CA 93612-5699 USA (559) 292-1981 • (800) 289-9100 FAX (800) 289-9150 or (559) 292-3827 International customers call 1-559-292-1981 or FAX 1-559-348-1120 (Product specifications subject to change without notice.) C1043M-A ®