Page 2 - REVISION HISTORY; CONTENTS; LIST OF ILLUSTRATIONS
2 Pelco Manual C1488M-A (9/98) REVISION HISTORY Manual # Date Comments C1488M 6/98 Original version. C1488M-A 9/98 Rev A. Revised the manual to incorporate Spectra™Lite material. CONTENTS Section Page 1.0 GENERAL ..........................................................................................
Page 3 - IMPORTANT SAFEGUARDS AND WARNINGS; Only use replacement parts recommended by Pelco.; The product and/or manual may bear the following marks:; RISK OF; Please thoroughly familiarize yourself with the information
Pelco Manual C1488M-A (9/98) 3 1.0 GENERAL 1.1 IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should beobserved. 1. Installation and servicing should only be done by qualified service personneland conform to all local codes. 2. Unless the unit...
Page 4 - REGULATORY NOTICES; Reorient or relocate the receiving antenna.
4 Pelco Manual C1488M-A (9/98) 1.2 REGULATORY NOTICES NOTE: This equipment has been tested and found to comply with the limits of aClass B digital device, pursuant to part 15 of the FCC rules. These limits are de-signed to provide reasonable protection against harmful interference in a residen-tial ...
Page 5 - Figure 1. Back Box Parts; UNPACKING INSTRUCTIONS; PENDANT MODELS; RECOMMENDED TOOLS
Pelco Manual C1488M-A (9/98) 5 Figure 1. Back Box Parts COMPASS TOOL SAFETY BRACKET CONDUIT FITTING& LOCK NUT T-RAIL CLIP 1.3 UNPACKING INSTRUCTIONS Unpack and inspect all par ts carefully. Be sure to save the shipping box and any inserts. They are the safest material inwhich to make future ship...
Page 7 - CEILING AND BACK BOX PREPARATION; Carefully cut the circle out of the ceiling.; Be careful; Figure 2. Compass Tool
Pelco Manual C1488M-A (9/98) 7 3.0 INSTALLATION FOR IN-CEILING MODELS This manual covers the installation of the BB5A-F, BB5A-PB, BB5A-PG, BB5A-PG-E,BB5L-F, BB5L-PG, and BB5L-PG-E back boxes only. For complete installation andoperating instructions for the SD5 Series of Spectra™ (Software Version 3....
Page 8 - Cable Type* Maximum Distance; Table A. Video Coaxial Cable; Wiring Distances
8 Pelco Manual C1488M-A (9/98) 3.1.2 Suspended Ceiling 1. Remove the ceiling tile from the ceiling. 2. Locate the center point to drill a hole in the tile. 3. Drill a hole in the ceiling tile using a 3/32-inch drill bit. 4. Remove the compass tool from the parts bag (refer to Figure 2). Press thestu...
Page 9 - HARD CEILING
Pelco Manual C1488M-A (9/98) 9 Figure 4. Installing Back Box Figure 5. Fastening Back Box HARD CEILING OR CEILING TILE T-RAIL CLIPFORCEILING TILE HARD CEILING OR CEILING TILE T-RAIL CLIPFORCEILING TILE
Page 10 - Figure 7. Wiring Diagram for SpectraTM Lite
10 Pelco Manual C1488M-A (9/98) Figure 6. Wiring Diagram for Spectra™ (Ver. 3.0) and Spectra II™ CONTROL (RS-422) 7 +5 to +24 VDC EXTERNAL RELAY (WIRING EXAMPLE) CONTROL (RS-422) Figure 7. Wiring Diagram for Spectra™ Lite
Page 11 - Maxim; A dome that requires; Distances are calculated in
Pelco Manual C1488M-A (9/98) 11 Table B. 24 VAC Wiring Distances The following are the recommended maximum distances for 24 VAC with a 10-percent voltage drop. (Ten percent is generally the maximum allowable voltage dropfor AC-powered devices.) Wire Gauge Maxim um distance fr om transf ormer to load...
Page 12 - BACK BOX INSTALLATION; If; Figure 8. Interconnect Door
12 Pelco Manual C1488M-A (9/98) 3.3 BACK BOX INSTALLATION 1. Suspended Ceiling Only (for hard ceiling, go to step 2) – Install the ceilingtile with the back box. Attach a T-rail clip on each side of the ceiling tile asshown in Figure 5. The clips for the ceiling tile are supplied with the back box. ...
Page 13 - BACK BOX CONNECTIONS; Video - Connect the coaxial cable to the BNC video connector.; Make sure; Figure 9. Transformer Wiring; If each dome
Pelco Manual C1488M-A (9/98) 13 3.4 BACK BOX CONNECTIONS Depending on the type of dome, refer to either Figure 10 or 11 to attach the wiring to theinterconnect circuit board inside the back box. Also refer to Figure 6 or 7 if necessary. 1. Earth Ground - Connect ear th ground to the middle connector...
Page 14 - Connect only a low volt-; Control - If you are using a Coaxitron; controller, control signals will be trans-; Figure 11. Interconnect Circuit Board for SpectraTM Lite
14 Pelco Manual C1488M-A (9/98) From controller To 4-Wire terminal on circuit board RX- TX- RX+ TX+ TX- RX- TX+ RX+ NOTE: Connect only a low volt- age device to the relay output.Maximum current rating of the re-lay contacts is two amperes. CAUTION: The maxi- mum output of AUX 2 is150 mA. If you conn...
Page 15 - If outdoors, apply Duct; INSTALLATION FOR PENDANT MODELS
Pelco Manual C1488M-A (9/98) 15 NOTE: If outdoors, apply Duct Seal inside the pipe por tion of theback box to prevent moisture orcold air inside the mount from en-tering the unit and causing conden-sation on the dome. Duct Seal canbe purchased through local elec-trical supply houses. 4.0 INSTALLATIO...
Page 16 - To remove the back box electronic assembly:
16 Pelco Manual C1488M-A (9/98) 5.0 TROUBLESHOOTING Symptom: LED does not light. If the red power LED on the door of the interconnect circuit board in the back boxdoes not light: 1. Turn off power. 2. Open the door to the interconnect circuit board and check the fuse. Refer toFigure 10 for the locat...
Page 18 - Figure 12. SD5 Series Dimension Drawing
18 Pelco Manual C1488M-A (9/98) Figure 12. SD5 Series Dimension Drawing 6.60 (16.76) 5.25 (13.34) 3.25 (8.26) 7.25 (18.13) 8.25 (20.96) 5.90 (14.99) In-Ceiling Dome Pendant Dome NOTE: VALUES IN PARENTHESES ARE CENTIMETERS, ALL OTHERS ARE INCHES. 5 . 9 0 ( 1 4 . 9 9 ) 1 0 . 9 02 7 . 6 9 6 . 7 5 ( 1 7...
Page 19 - NOTES
Page 20 - WARRANTY AND RETURN INFORMATION; WARRANTY
20 Pelco Manual C1488M-A (9/98) 7.0 WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective inmaterial or workmanship for a period of one year after the date of shipment. Excep-tions to this warranty are as noted below: • Three years on...