Page 2 - CONTENTS; LIST OF ILLUSTRATIONS
CONTENTS IMPORTANT SAFEGUARDS AND WARNINGS ......................................................................................................... 3 DESCRIPTION ............................................................................................................................................
Page 3 - IMPORTANT SAFEGUARDS AND WARNINGS; Only use replacement parts recommended by Pelco.; This symbol indicates that there are important
IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R,...
Page 4 - DESCRIPTION; MODELS; In-ceiling back box with reinforced bracket-mounting system; Back Box Model; The following items are supplied:; PENDANT MODELS; Tube of thread compound
DESCRIPTION The Heavy-duty Spectra is perfect for installations where structural integrity and vandalism are a priority. The system features barrel key locks, heavy-duty construction and a thick acrylic lower dome. The in-ceiling model has a reinforced bracket mounting system for installation in a f...
Page 6 - STEP 6 - INSTALL LOWER DOME; b. Insert both keys in the barrel locks. Turn keys clockwise to the; TO USE YOUR DOME, REFER TO THE OPERATION AND
STEP 4 - WIRE CIRCUIT BOARD Attach the wiring to the circuit board inside the back box. When finished, close the door to the back box and turn on the power. The red LED will light. IMPORTANT: If the LED does not light, refer to the Trouble shooting section. NOTE: Aux 1 - Maximum 2A at low voltage (...
Page 8 - STEP 3 - INSTALL DOME DRIVE; a. Set the DIP switches for SW1 and SW2 on the bottom of the; STEP 4 - INSTALL LOWER DOME; the groove on the trim ring of the lower dome.; Environmental Model only:; Plug the two-pin heater
STEP 3 - INSTALL DOME DRIVE LABEL SW1 LABEL SW2 SW1 SW2 RS-422 TERMINATION SWITCH ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 SW2 GREEN TAB RED TAB 00538 a. Set the DIP switches for SW1 and SW2 on the bottom of the dome drive for the appropriate receiver address. Refer to the labels on the dome drive or t...
Page 9 - TROUBLESHOOTING
TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Unit does not operate. The controller is not communicating with the Spectra unit. Check to see if the red LED on the circuit board in the back box is lit. 1. The red LED is not lit . a. Fuse is bad. b. 24 VAC power source is not con nected or back box...
Page 10 - APPENDIX; Video Coaxial Cable Wiring Distances
APPENDIX Table A. Video Coaxial Cable Wiring Distances Cable Type* Maximum Distance RG59/U RG6/U RG11/U 750 ft (229 m) 1,000 ft (305 m) 1,500 ft (457 m) * Minimum cable requirements: 75 ohms impedance. All-copper center conductor. 95% braided copper shield. Table B. 24 VAC Wiring Distances The follo...
Page 14 - SPECIFICATIONS; MECHANICAL
SPECIFICATIONS MECHANICAL Construction Back box: Aluminum Dome drive: Aluminum, ABS plastic Lower dome: Acrylic Cable Entry In-Ceiling: .75-inch (1.91 cm) conduit fitting Pendant: Through 1.5-inch (3.81 cm) NPT pendant mount Pan Movement: 360 ° continuous pan rotation Vertical Tilt: Unobstructed +2 ...
Page 15 - GENERAL; Back Box; Dimension Drawing
GENERAL Environment In-Ceiling: Indoor only Pendant: Indoor/outdoor Operating Range In-Ceiling: 32 to 140 ° F (0 to 60 ° C) intermittent operation; 32 to 122 ° F (0 to 50 ° C) continuous operation Pendant Without Heater: 32 to 140 ° F (0 to 60 ° C) absolute maximum operating temperature; 32 to 122 °...
Page 16 - PRODUCT WARRANTY AND RETURN INFORMATION; REVISION HISTORY; Comments
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or workmanship for a period of one year after the date of shipment. (559) 2...