LIABILITY DISCLAIMER NEC America, Inc. reserves the right to change the specifications, functions, orfeatures, at any time, without notice. NEC America, Inc. has prepared this document for use by its employees andcustomers. The information contained herein is the property of NEC America,Inc. and sha...
ND-70185 (E) ISSUE 3 MAY, 2000 NEAX2400 IMX Fusion Network System Manual TABLE OF CONTENTS Page ND-70185 (E) TABLE OF CONTENTS Page i Revision 3.0 CHAPTER 1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1. General...
TABLE OF CONTENTS ND-70185 (E) Page iiRevision 3.0 TABLE OF CONTENTS (CONTINUED) Page 3. Mounting Circuit Cards in PIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 403.1 Mounting HUB (PA-M96) in a PIM. . . . . . . . . . . . . . . . . ....
ND-70185 (E) TABLE OF CONTENTS Page iii Revision 3.0 TABLE OF CONTENTS (CONTINUED) Page 8. Office Data Sheets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1128.1 Data Sheet for AFMUPL . . . . . . . . . . . . . . . . ....
TABLE OF CONTENTS ND-70185 (E) Page ivRevision 3.0 TABLE OF CONTENTS (CONTINUED) Page CHAPTER 7 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 1. List of Fusion-related System Messages . . . . . . . . . . . . . . . . . ...
LIST OF FIGURES Figure Title Page ND-70185 (E) LIST OF FIGURES Page v Revision 3.0 Figure 2-1 Telephone Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Figure 2-2 Free Location . . . . . . . . . . . . . . . . . . . . . . . . ...
LIST OF TABLES Table Title Page ND-70185 (E) LIST OF TABLES Page ix Revision 3.0 Table 4-1 SENSE Switch Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Table 4-2 MODE Switch Setting. . . . . . . . . . . . . . . . . . . . . . ...
LIST OF TABLES ND-70185 (E) Page xRevision 3.0 This page is for your notes.
ND-70185 (E) CHAPTER 1 Page 1 Revision 3.0 CHAPTER 1 INTRODUCTION 1. General This manual covers the installation of the Fusion system. 2. How to Follow This Manual This manual consists of the following chapters. • CHAPTER 1 (INTRODUCTION) Explains how to use this manual. • CHAPTER 2 (GENERAL) Outlin...
CHAPTER 1 ND-70185 (E) Page 2Revision 3.0 INTRODUCTIONRelated Manuals 3. Related Manuals To complete the installation of the Fusion system, the following manuals are required: • NEAX2400 IMX Circuit Card Manual • NEAX2400 IMX Installation Manual • NEAX2400 IMX Office Data Specification This manual a...
ND-70185 (E) CHAPTER 2 Page 3 Revision 3.0 CHAPTER 2 GENERAL 1. What is Fusion and its Advantages The main advantages of the Fusion network are as follows: 1.1 Improved Inter-Office Service Features The Fusion system can eliminate the constraints normally associated with network services that are of...
CHAPTER 2 ND-70185 (E) Page 4Revision 3.0 GENERALFree Numbering 2. Free Numbering A Telephone Number can be assigned to a desired station on the Fusion network using the simple commandoperation shown below. Figure 2-2 Free Location 2.1 Centralized Maintenance Administration Terminal (MAT) A Fusion n...
ND-70185 (E) CHAPTER 2 Page 5 Revision 3.0 GENERAL Fusion System Configuration 3. Fusion System Configuration The Fusion system can be divided into the following two types. Figure 2-4 shows a Fusion system with Fusion Call Control Handler (FCH) cards. Figure 2-4 Fusion System Configuration (with FCH...
CHAPTER 2 ND-70185 (E) Page 6Revision 3.0 GENERALNode 4. Node A Fusion network consists of the following types of nodes: • Network Control Node Network Control Node, which must be assigned on a Fusion network, manages other nodes on the network.This node has the Centralized-MAT to collect fault info...
ND-70185 (E) CHAPTER 2 Page 7 Revision 3.0 GENERAL Data Memory Configuration 5. Data Memory Configuration Each node on a Fusion network has the following three kinds of Data Memory: • Data Memory (DM) • Local Data Memory (LDM) • Network Data Memory (NDM) - Programmable only by the NCN. When the cont...
CHAPTER 2 ND-70185 (E) Page 8Revision 3.0 GENERALFusion Network Examples When the NDM (master) is modified, the new data is automatically copied. Figure 2-8 Network Data Memory Copy 6. Fusion Network Examples Figure 2-9 and Figure 2-10 show examples of Fusion networks. When incorporating the Fusion ...
ND-70185 (E) CHAPTER 2 Page 9 Revision 3.0 GENERAL Fusion Network Examples Figure 2-10 Open Numbering Fusion-CCIS Network [conditions for Telephone Number Digits]When incorporating the Fusion system with the CCIS network, consider the following conditions as to the available Telephone Number digits:...
CHAPTER 2 ND-70185 (E) Page 10Revision 3.0 GENERALTandem Connections via Fusion Link 7. Tandem Connections via Fusion Link Tandem connections via FCCS-ACIS can be established. In Figure 2-11 , STN (A) can place a tandem call via FCCS-ACIS. Figure 2-11 Tandem Connections via Fusion Link 430000 TELN 4...
ND-70185 (E) CHAPTER 3 Page 11 Revision 3.0 CHAPTER 3 SYSTEM CONFIGURATION Fusion systems can be divided into the following two types: • Fusion system with FCH • Fusion system without FCH Note: Fusion Call Control Handler (FCH): PA-FCHA This chapter explains the system configuration of each Fusion s...
CHAPTER 3 ND-70185 (E) Page 12Revision 3.0 SYSTEM CONFIGURATIONFusion System with FCH 2. Fusion System with FCH 2.1 System Configuration A sample Fusion system configuration that uses a DTI to carry D-channel is shown below. In this configu-ration, the Fusion link is established between nodes via th...
ND-70185 (E) CHAPTER 3 Page 13 Revision 3.0 SYSTEM CONFIGURATION Fusion System with FCH In Figure 3-3 LANI, HUB, FCH, and DTI are shown in a fully redundant configuration. This configuration is available for Release 3 or later software. Figure 3-3 Redundant Configuration (LANI, HUB, FCH, and DTI) In...
CHAPTER 3 ND-70185 (E) Page 14Revision 3.0 SYSTEM CONFIGURATIONSystem Considerations In Figure 3-6 , no redundancy is shown in the Fusion link. Figure 3-6 Non-Redundant Configuration 3. System Considerations 3.1 Fusion Network Conditions This section explains how to design a Fusion network. In the f...
ND-70185 (E) CHAPTER 3 Page 15 Revision 3.0 SYSTEM CONFIGURATION System Considerations Condition 2: A maximum of four (4) nodes can be connected as tandem nodes. Figure 3-8 Fusion Tandem Connections Condition 3: The available connection-route number ranges from 1 to 1023. Condition 4: The available ...
CHAPTER 3 ND-70185 (E) Page 16Revision 3.0 SYSTEM CONFIGURATIONSystem Considerations Condition 5: Up to eight (8) routes can be assigned as alternate routes for a connection trunk. Figure 3-10 Connection Trunk Alternate Routing Condition 6: Connection trunks and the Fusion data link must be assigned...
ND-70185 (E) CHAPTER 3 Page 21 Revision 3.0 SYSTEM CONFIGURATION System Considerations 3.3 Centralized Management Report-Fusion To collect fault information in a Fusion network, the Centralized Management Report-Fusion is used. Thisfeature provides automatic reporting of fault occurrence from Local ...
CHAPTER 3 ND-70185 (E) Page 22Revision 3.0 SYSTEM CONFIGURATIONSystem Considerations The following explains service conditions for the network including both FCCS and CCIS links. Example: 1 When the network comprises FCCS and CCIS links Figure 3-14 Centralized Management Report-Fusion (Example 1) No...
ND-70185 (E) CHAPTER 3 Page 23 Revision 3.0 SYSTEM CONFIGURATION System Considerations Example: 2 When both FCCS and CCIS links are established between two nodes Figure 3-15 Centralized Management Report-Fusion (Example 2) Node A/B/C:Refer to Example 1 on the previous page. Node D: When Point Code o...
CHAPTER 3 ND-70185 (E) Page 24Revision 3.0 SYSTEM CONFIGURATIONSystem Considerations Example: 3 When a node is linked with LAN interface Figure 3-16 Centralized Management Report-Fusion (Example 3) Node A: To send system messages to Node E, assign Point Code of Node C (1) to ASYD, SYS 1, Indexes184 ...
ND-70185 (E) CHAPTER 3 Page 27 Revision 3.0 SYSTEM CONFIGURATION System Considerations 3.4.3 Day/Night Change Day/Night information is transferred from an ATTCON/DESKCON to predetermined nodes. In this example,Node C specifies Node A and Node B as destination nodes by assigning FPCs 1 and 2 in Index...
ND-70185 (E) CHAPTER 4 Page 29 Revision 3.0 CHAPTER 4 INSTALLATION This chapter covers the installation of the Fusion system. The following topics are covered: • How to set switches on the following circuit cards: PA-M96 (HUB) PA-FCHA (FCH) PA-24DTR (DTI) • How to mount the circuit cards • How to ru...
CHAPTER 4 ND-70185 (E) Page 30Revision 3.0 INSTALLATIONAnti-Static Caution Figure 4-2 shows the anti-static kit that is provided. Use the kit as shown below when handling static-sensitive components such as circuit cards and cables. Figure 4-2 How to Use the Anti-static Kit PBX Connect the ground wi...
ND-70185 (E) CHAPTER 4 Page 31 Revision 3.0 INSTALLATION Anti-Static Caution 1.1 Circuit Cards Required Depending on the system type, the following circuit cards are required to install the Fusion system: • Fusion with FCH HUB (PA-M96) FCH (PA-FCHA) DTI (PA-24DTR) • Fusion without FCH DTI (PA-24DTR)...
CHAPTER 4 ND-70185 (E) Page 32Revision 3.0 INSTALLATIONKey Setting on Circuit Cards 2. Key Setting on Circuit Cards 2.1 PA-M96 (HUB) Set the SEL switch on the HUB (PA-M96) card(s), after referring to Figure 4-4 and Table 4-1 . Figure 4-4 Switch Setting on HUB (PA-M96) Card Table 4-1 SENSE Switch Set...
ND-70185 (E) CHAPTER 4 Page 33 Revision 3.0 INSTALLATION Key Setting on Circuit Cards 2.2 PA-FCHA (FCH) Set the switches on the FCH (PA-FCHA) card(s) as shown below. This card has DIP switches, whose keysettings determine the time slots of the Fusion link. In Figure 4-5 , CH3 is designated as the D/...
ND-70185 (E) CHAPTER 4 Page 35 Revision 3.0 INSTALLATION Key Setting on Circuit Cards 2.3 PA-24DTR (DTI) There are two types of the PA-24DTR (DTI) card as shown below. Refer to Figure 4-6 and Table 4-4 to set each switch to the proper positions. Figure 4-6 Switch Locations on DTI (PA-24DTR) Card Tab...
ND-70185 (E) CHAPTER 4 Page 37 Revision 3.0 INSTALLATION Key Setting on Circuit Cards SW39 1 ON OFF × 2 ON × OFF 3 ON × OFF 4 ON × OFF 5 ON × OFF 6 ON OFF × 7 ON × OFF 8 ON OFF × Table 4-4 Switch Setting Patterns for the DTI Card (Continued) SWITCH NAME SWITCH NUMBER SETTING STANDARD SETTING MEANING...
CHAPTER 4 ND-70185 (E) Page 38Revision 3.0 INSTALLATIONKey Setting on Circuit Cards SW6C 1 ON × Fixed 2 ON × Fixed 3 ON × Fixed 4 ON × Fixed 5 ON × Fixed 6 ON × Fixed 7 ON × Fixed 8 ON × Fixed SW58 1 ON Equalizer Setting OFF 2 ON OFF 3 ON OFF 4 ON PAD Pattern Selection Note: When setting this key, r...
CHAPTER 4 ND-70185 (E) Page 40Revision 3.0 INSTALLATIONMounting Circuit Cards in PIM 3. Mounting Circuit Cards in PIM 3.1 Mounting HUB (PA-M96) in a PIM Mount the HUB (PA-M96) card in an appropriate slot of a PIM as shown below. When the MAT is con-nected via a HUB card, be sure to use a dedicated H...
ND-70185 (E) CHAPTER 4 Page 41 Revision 3.0 INSTALLATION Mounting Circuit Cards in PIM 3.2 Mounting FCH (PA-FCHA) and DTI (PA-24DTR) Cards Mount the FCH (PA-FCHA) and the DTI (PA-24DTR) card in appropriate slots in a PIM. Mount the twocards in adjacent slots since these cards must be connected on th...
CHAPTER 4 ND-70185 (E) Page 42Revision 3.0 INSTALLATIONConnecting Cables 4. Connecting Cables 4.1 Connecting DTI-FCH Front Cables Connect the furnished front cable to the connectors on the DTI and FCH cards. Use DTI and CN2 connec-tors on the FCH and DTI cards respectively. Since an FCH card is equi...
ND-70185 (E) CHAPTER 4 Page 43 Revision 3.0 INSTALLATION Connecting Cables Since a maximum of five Handler circuits can be used, five FCH cards can be cascaded. Figure 4-10 shows an example where three FCH cards are cascaded. Figure 4-10 FCH Cascade Connections ATTENTION ContentsStatic SensitiveHand...
CHAPTER 4 ND-70185 (E) Page 44Revision 3.0 INSTALLATIONConnecting Cables 4.2 Connecting 10 BASE-T Cables Figure 4-11 shows sample cable connections, where HUB (PA-M96) cards are provided in a dual configu- ration and the FCH (PA-FCHA) card is located in PIM 1 (1-IMG system/IMG0). When HUB cards are ...
ND-70185 (E) CHAPTER 4 Page 45 Revision 3.0 INSTALLATION Connecting Cables 4.3 10 BASE-T Connection Procedure The pattern for 10 BASE-T cable connections may vary, depending on the system configuration (such asnumber of IMG stacks or the mounting location/number of the FCH/HUB cards, etc.). Accordin...
CHAPTER 4 ND-70185 (E) Page 46Revision 3.0 INSTALLATIONConnecting Cables 4.3.3 When not using the cable unit SR1201 ETIF CAU-n When your system doesn’t use the cable unit classified as SR1201 ETIF CAU-n, perform the 10 BASE-T connections as instructed below: 1. Depending on your system configuration...
ND-70185 (E) CHAPTER 4 Page 47 Revision 3.0 INSTALLATION Connecting Cables When dual LANIs are used in both Slot 00 and 03 of CPR#0/CPR#1, be sure to use at least twoHUB cards as separate 10 BASE-T connection terminals. Use one HUB for the internal LANI(LANI-A: in Slot 00 of each CPR) and use the ot...
CHAPTER 4 ND-70185 (E) Page 48Revision 3.0 INSTALLATIONConnecting Cables When dual FCH is provided for the HUB dedicated to each internal LANI card (LANI-A: in Slot00 of each CPR), connect FCH#0 to HUB#0 and FCH#1 to HUB#1. When your system also uses the external LANI cards (LANI-B in Slot 03 of eac...
ND-70185 (E) CHAPTER 4 Page 49 Revision 3.0 INSTALLATION Connecting Cables Figure 4-13 shows some typical examples, where 10 BASE-T cables are connected to the FCH card(s) mounted in PIM0 of 1-IMG system, under the following conditions: Note 1: Cables Contained in each cable unit are as follows.SR12...
CHAPTER 4 ND-70185 (E) Page 50Revision 3.0 INSTALLATIONConnecting Cables Figure 4-13 Examples of Ethernet Cable Connection-FCH in PIM0 (1-IMG System) (2/2) ATTENTION ContentsStatic SensitiveHandlingPrecautions Required 06 04 05 03 02 01 00 06 04 05 03 02 01 00 CN CN CN CN HUB CN CN HUB BASEU PIM 1 P...
ND-70185 (E) CHAPTER 5 Page 57 Revision 3.0 CHAPTER 5 DATA PROGRAMMING This chapter explains how to set Fusion Network data, using the following data categories: • System Data • Numbering Plan Data • Station Data • Fusion Link Data Figure 5-1 shows the overall data programming procedure: Figure 5-1 ...
CHAPTER 5 ND-70185 (E) Page 58Revision 3.0 DATA PROGRAMMINGNetwork Data Programming Summary 1. Network Data Programming Summary This section explains a summary of the data programming of Fusion systems. 1.1 Brand-new Fusion Network To install the Fusion network as a brand-new system, the overall dat...
ND-70185 (E) CHAPTER 5 Page 59 Revision 3.0 DATA PROGRAMMING Network Data Programming Summary 1.2 Upgrading a CCIS Network To install the Fusion system to an existing CCIS network, the overall programming procedure is as follows: 1.2.1 System Data • Decide an NCN and LN on the network. • Assign Syst...
ND-70185 (E) CHAPTER 5 Page 61 Revision 3.0 DATA PROGRAMMING Network Data Programming Summary Figure 5-3 shows how to upgrade an existing CCIS network, focusing on the Numbering Plan. The example data setting assumes the existing network uses this particular numbering. For more detailed information ...
CHAPTER 5 ND-70185 (E) Page 62Revision 3.0 DATA PROGRAMMINGAssignment of System Data 2. Assignment of System Data STEP 1: ASYDL and ASYDN Assign the number of data memory blocks for the Network Data Memory (NDM) and the Local DataMemory (LDM). Use the ASYDN command for the NCN. Use the ASYDL command...
ND-70185 (E) CHAPTER 5 Page 63 Revision 3.0 DATA PROGRAMMING Assignment of System Data STEP 2: ASYDL Assign the self-Fusion Point Code (self-FPC) at each node. FPC ranges from 1 to 253. Use the ASY-DL command. (Index 512 b0-b7) • Index 512 self-Fusion Point Code Assign a unique FPC for each node. Fi...
CHAPTER 5 ND-70185 (E) Page 64Revision 3.0 DATA PROGRAMMINGAssignment of System Data Index 800 For ASYDL b0 : 0/1 = ALGNL, ALGSL on a UGN (TN) basis/-b1 : 0/1 = ASPAL on a TN basis/-b2 : 0/1 = ANPDL on a TN basis/-b4 : 0/1 = AFRSL, ASTPL, AUNEL on a TN basis/-b5 : 0/1 = ASTPL on a TN basis/-b7 : 0/1...
ND-70185 (E) CHAPTER 5 Page 65 Revision 3.0 DATA PROGRAMMING Assignment of FPC and MG and UNIT into Network 3. Assignment of FPC and MG and UNIT into Network 3.1 AFMU Assign the module accommodation data by giving Module Group Number and Unit Number on an FPCbasis. This data is necessary to allocate...
CHAPTER 5 ND-70185 (E) Page 66Revision 3.0 DATA PROGRAMMINGAssignment of Logical RT in Network DM (NDM) 4. Assignment of Logical RT in Network DM (NDM) 4.1 ALRTN/ARTKN This command is used to assign Logical Route Numbers to all external trunks used on a Fusion network.Assign unique Telephone Numbers...
ND-70185 (E) CHAPTER 5 Page 67 Revision 3.0 DATA PROGRAMMING Assignment of Numbering Data for Telephone Numbers The ALRTN command display should look similar to the following: Figure 5-12 ALRTN Command Display 5. Assignment of Numbering Data for Telephone Numbers STEP 1: ANPDN Make a Telephone Numbe...
CHAPTER 5 ND-70185 (E) Page 68Revision 3.0 DATA PROGRAMMINGAssignment of Numbering Data for Telephone Numbers STEP 2: ANPDN Assign Pre-translation Data for the Telephone Numbers planned in Step 1 using the ANPDN com-mand at NCN. In Figure 5-14 , the data setting should be as follows: Figure 5-14 ANP...
ND-70185 (E) CHAPTER 5 Page 69 Revision 3.0 DATA PROGRAMMING Assignment of Numbering Data for Telephone Numbers STEP 3: ASPAN Assign special access code data for the Telephone Numbers using the ASPAN command.SRV=TELN is the data for Telephone Numbers. Figure 5-16 ASPAN Sample Data Sheet Figure 5-17 ...
CHAPTER 5 ND-70185 (E) Page 70Revision 3.0 DATA PROGRAMMINGAssignment of Telephone Numbers 6. Assignment of Telephone Numbers This section explains how to program Telephone Numbers. To program Telephone Numbers, use ALGSN com-mand. Telephone Number can be assigned to a station using the LENs or the ...
CHAPTER 5 ND-70185 (E) Page 72Revision 3.0 DATA PROGRAMMINGAssignment of Telephone Numbers 6.1 Assignment of Connection Route/Trunk Data STEP 1: ACRD Using the ACRD command, assign the connection route data of Fusion link. The data must be assigned for bothB-channel and D-channel. Assign appropriate...
CHAPTER 5 ND-70185 (E) Page 74Revision 3.0 DATA PROGRAMMINGAssignment of Telephone Numbers CDN 1: Trunk Kind0-2: -3: Bothway Trunk CDN 2: TCL (Trunk Class)0-3: -4: Fusion Trunk5-31: - CDN 3: RLP (Release Pattern)0: Calling Party Release1: -2: First Party Release3: - CDN 4: SMDR (SMDR for station-to-...
CHAPTER 5 ND-70185 (E) Page 76Revision 3.0 DATA PROGRAMMINGAssignment of Telephone Numbers STEP 2: ACTK Assign the connection trunk data of both B-channel and D-channel using the ACTK command. As-sign the Connection Equipment Number (C_LENS) referring to Figure 5-22 through Figure 5-25 . The ACTK co...
ND-70185 (E) CHAPTER 5 Page 77 Revision 3.0 DATA PROGRAMMING Assignment of Telephone Numbers Table 5-2 Data Programming Sheet for Regular Density Slot C_RT (1-1023) C_TK(1-4095) C_LENS Time Slot Allocation MG U G LV 10 (B-ch) 1 0 0 0 0 1 0 2 0 0 0 0 1 1 3 0 0 0 0 1 2 4 0 0 0 0 1 3 5 0 0 0 0 1 4 6 0 ...
CHAPTER 5 ND-70185 (E) Page 78Revision 3.0 DATA PROGRAMMINGAssignment of Telephone Numbers 6.1.2 When FCH is Mounted in a High Density Slot If the FCH is to be mounted in the High Density Slot, the connection trunk data should be assigned asshown in the figures below. Figure 5-24 shows an example wh...
ND-70185 (E) CHAPTER 5 Page 79 Revision 3.0 DATA PROGRAMMING Assignment of Telephone Numbers When the DTI cards is mounted in a double density slot, the C_LEN data for the FCH and DTI cardsare as follows. Figure 5-25 How to Assign C_LEN Data (Type 2) 00 02 04 05 06 07 08 09 10 11 12 13 14 15 16 17 1...
ND-70185 (E) CHAPTER 5 Page 81 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data STEP 4: MBCT Unbusy the connection trunk data assigned in the previous step using MBCT (Make Busy of Connec-tion Trunk) command. This step is required for both B-channel and D-channel trunk. The MBCTcommand s...
CHAPTER 5 ND-70185 (E) Page 82Revision 3.0 DATA PROGRAMMINGAssignment of FCH Related Data Figure 5-29 shows a sample data assignment when FCH cards are located in the PIM 0 slot 4 and PIM 2 slot 11. Figure 5-27 Assignment of FCH Number The AFCH command display should look similar to the following: F...
ND-70185 (E) CHAPTER 5 Page 83 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data STEP 2: AFRT (Fusion with FCH only) Assign connection route numbers as shown below using the AFRT command. Figure 5-29 AFRT Sample Data Sheet The AFRT command display should look similar to Figure 5-30 . Figu...
CHAPTER 5 ND-70185 (E) Page 84Revision 3.0 DATA PROGRAMMINGAssignment of FCH Related Data STEP 3: AFPC Assign FCH routing data using the AFPC command. A maximum of 8 connection routes and FCHN/FPCN can be assigned on a node basis. FCHN is used for Fusion System with FCH. FPCN is usedfor Fusion Syste...
ND-70185 (E) CHAPTER 5 Page 85 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data The table in Figure 5-33 shows a sample data sheet for Node A on a Fusion network with FCH. Assign the data for all nodes including the nodes which are not directly connected on the network. For example, in t...
CHAPTER 5 ND-70185 (E) Page 86Revision 3.0 DATA PROGRAMMINGAssignment of FCH Related Data STEP 4: ACAN Assign the Fusion Connection Index Code (FCIC) and the LENs on an adjacent FPC basis. Figure 5- 34 shows a sample data sheet for Node A. Note: It is not necessary to assign the same number as trunk...
ND-70185 (E) CHAPTER 5 Page 87 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data 7.1 Assignment of Access Code for Tandem Connection via FCCS - ACIS For Release 3 or later software, tandem connection via FCCS - ACIS link can be established. Using LDM,appropriate routing data for each node...
CHAPTER 5 ND-70185 (E) Page 88Revision 3.0 DATA PROGRAMMINGAssignment of FCH Related Data STEP 1: ANPDN/ANPDL Note Assign the first digit of the OGC access code. When the access code is common to all nodes, use theANPDN command. When the access code is assigned for each node, use the ANPDL command. ...
ND-70185 (E) CHAPTER 5 Page 89 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data 7.1.2 OGCA A procedure for assigning OGCA access code is explained using the following example. Figure 5-37 Example of OGCA STEP 1: ANPDN/ANPDL Note Assign the first digit of the OGCA access code. When the ac...
ND-70185 (E) CHAPTER 5 Page 91 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data STEP 1: ANPDN/ANPDL Note Assign the first digit of the LCR/LCRS access code. When the access code is common to all nodes,use the ANPDN command. When the access code is assigned for each node, use the ANPDL co...
CHAPTER 5 ND-70185 (E) Page 92Revision 3.0 DATA PROGRAMMINGAssignment of FCH Related Data STEP 5: ARTD/ARTDN Using ARTD, assign the following CDN data for the dummy route number. Note 1 CDN 6 (TCL)=1 or 4 (depending on requirement) CDN 7 (L/T)=1 CDN 13 (AC)=1 The other CDNs may be left default (data...
ND-70185 (E) CHAPTER 5 Page 93 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data 7.2 Data Assignment for 52M-SDH Interface This section explains the Fusion Connection with 52M-SDH interface, which is available for Release 4 orlater software. The figures below explain the connection patter...
CHAPTER 5 ND-70185 (E) Page 94Revision 3.0 DATA PROGRAMMINGAssignment of FCH Related Data Specifications for the SDH data setting are described below. 1. When FCCS and CCIS links are used together in the network, the different route number must be assignedto each Connection Trunk (B-ch), Connection ...
ND-70185 (E) CHAPTER 5 Page 95 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data • Connection Link (for Data) C_RT: 11 TCL=4 LSG=13 STEP 3: ACTK Assign the Connection Trunk data for B-ch and D-ch. Example: (When using 512kbps (8ch) TS as Connection link) • Connection trunk (B-ch) C_RT: 10...
ND-70185 (E) CHAPTER 5 Page 97 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data 7.3 FCCS Link via Internet/Intranet The system can exchange FCCS data via the Internet/Intranet. As shown below, an FCCS Link can be es-tablished by using the following features: • External Router • Fusion ov...
CHAPTER 5 ND-70185 (E) Page 98Revision 3.0 DATA PROGRAMMINGAssignment of FCH Related Data STEP 1: ACRD Assign Route Class Data of Speech Route, FCH, FGH routes, respectively. A sample data assignmentis shown below. See 6.1 Assignment of Connection Route/Trunk Data for more detailed information. Figu...
ND-70185 (E) CHAPTER 5 Page 99 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data STEP 2: ACTK Assign the connection trunk data of DTI, FCH, and FGH cards, using the ACTK command. Whenassigning FCH, FGH trunk data, eight trunks must be set. A sample data assignment of FCH, FGHcard is as fo...
CHAPTER 5 ND-70185 (E) Page 100Revision 3.0 DATA PROGRAMMINGAssignment of FCH Related Data STEP 3: AFCH Assign FCH number on an FCH circuit card basis. In the following example, FCHN=1 is assignedfor the FCH circuit card. For the FGH card, FCHN assignment is not necessary. Figure 5-43 Assignment of ...
ND-70185 (E) CHAPTER 5 Page 101 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data STEP 5: AFPCAssign internal LAN routing data. FPC (Fusion Point Code): Assign FPC number (1-253) of the Destination Node.FCCH: Assign "1".C_RT (Connection Router): 1-1023FCHN/FPCN (FCH/FPC Number): A...
CHAPTER 5 ND-70185 (E) Page 102Revision 3.0 DATA PROGRAMMINGAssignment of FCH Related Data STEP 6: AETH Assign the external router routing data. FPC (Fusion Point Code): Assign FPC number (1-253) of the Destination Node.USE_GATE: Assign "1 (=use Gateway)".FCHN (FCH Number): Assign the FCH Nu...
ND-70185 (E) CHAPTER 5 Page 103 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data STEP 7: ACAN Assign the Fusion Connection Index Code (FCIC) for the Next Node. FPC (Fusion Point Code): Assign FPC number of the Next Node (Node to be passed to).FCIC (Fusion Connection Index Code): Assign F...
CHAPTER 5 ND-70185 (E) Page 104Revision 3.0 DATA PROGRAMMINGAssignment of FCH Related Data 7.3.2 FCCS Networking over IP This feature allows the system to exchange both speech and FCCS signaling over Internet/Intranet. Toestablish/release a call, Q-sig is used between the system and the router. H.32...
ND-70185 (E) CHAPTER 5 Page 105 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data STEP 1: ACRD Assign Route Class Data of Speech Route, FCH, FGH routes, respectively. A sample data assignmentis shown below. Figure 5-51 Sample Data Assignment (ACRD) STEP 2: ACTK Assign the connection trunk...
ND-70185 (E) CHAPTER 5 Page 107 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data STEP 5: AETH Assign the FCCS routing data, when external router is used by specifying IP address. FPC (Fusion Point Code): Assign FPC number (1 - 253) of the Destination Node.USE_GATE: Assign "0 (= not u...
ND-70185 (E) CHAPTER 5 Page 109 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data STEP 8: AGIP Assign IP addresses of FGH card and its connected router. FCHEN (FCH Equipment Number): Assign LV0 data of FGH LENs.FGH_IP (FGH IP Address): Assign IP address of the FGH card.DG_IP (Default Gate...
CHAPTER 5 ND-70185 (E) Page 110Revision 3.0 DATA PROGRAMMINGAssignment of FCH Related Data STEP 9: AFIP Assign the FCCS Networking over IP data for controlling Speech Channels between PBX and router. FCHN (FCH Number): Assign FCHN specified in STEP 4.FGHEN (FGH Equipment Number): Assign LV0 data of ...
ND-70185 (E) CHAPTER 5 Page 111 Revision 3.0 DATA PROGRAMMING Assignment of FCH Related Data 7.4 Flexible Routing - FCCS A Fusion trunk call can be routed via "non-Fusion" trunk (C.O. or Tie Line), if the Fusion trunks are allbusy or Data Link Failure occurs at the FCH card, etc. This featur...
CHAPTER 5 ND-70185 (E) Page 112Revision 3.0 DATA PROGRAMMINGOffice Data Sheets 8. Office Data Sheets 8.1 Data Sheet for AFMUPL FUSION POINT CODE (FPC) 1-253 MODULE GROUP (MG) 0/1 UNIT 0-3 REMARKS 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
ND-70185 (E) CHAPTER 5 Page 113 Revision 3.0 DATA PROGRAMMING Office Data Sheets 8.2 Data Sheet for ALRTN LOGICAL ROUTE NUMBER (LGRT) 1-899 FUSION POINT CODE (FPC) 1-253 EXTERNAL ROUTE NUMBER (RT) 1-255 REMARKS
CHAPTER 5 ND-70185 (E) Page 120Revision 3.0 DATA PROGRAMMINGOffice Data Sheets 8.9 Data Sheet for ACRD CDN CONNECTION RT No. (C_RT) 1-1023 FUNCTION (FUNC) 1 TF - Type of Trunk0-2 = - 3 = Bothway Trunk (BWT) 3 3 3 3 3 3 2 TCL - Trunk Class (Fixed “4”) 0-3 = - 4 = Fusion Trunk 5-31 = - 4 4 4 4 4 4 3 R...
ND-70185 (E) CHAPTER 5 Page 121 Revision 3.0 DATA PROGRAMMING Office Data Sheets 10 FPEG - Fusion-PEG (Fixed “0”)0 = Nothing of FUSION-PEG1 = Exist of FUSION-PEG 0 0 0 0 0 0 11 TC - Timer Class (Fixed “0”) 1 = 1 sec. 2 = 2 sec. 3 = 8 sec. 4 = 30 sec. 0 0 0 0 0 0 12 MTC - Miscellaneous Timer Counter ...
ND-70185 (E) CHAPTER 6 Page 133 Revision 3.0 CHAPTER 6 POST INSTALLATION TEST This chapter covers how to perform installation tests focusing on the Fusion Call Control Signal (denoted in theremainder of this manual as FCCS) connections, after hardware installation and data assignment. This chapterde...
CHAPTER 6 ND-70185 (E) Page 134Revision 3.0 POST INSTALLATION TESTRepair Procedure When LED Indicates Abnormality 1.1 How to check LYR LED 1. Confirm the LYR LED lights green on the front edge of the FCH (PA-FCHA) circuit card. (See “LEDIndication (A)” in Figure 6-2 .) When the LED lights green, the...
ND-70185 (E) CHAPTER 6 Page 135 Revision 3.0 POST INSTALLATION TEST Repair Procedure When LED Indicates Abnormality • FCH (PA-FCHA) switch setting Make sure that the following keys are set properly: • Dch TS designation (0ch - 23ch: SW11, SW12, SW13) • Data Link Signal Logic (positive/negative: SW14...
CHAPTER 6 ND-70185 (E) Page 136Revision 3.0 POST INSTALLATION TESTRepair Procedure When LED Indicates Abnormality All 24 B-channels sent from the TSW are looped back to the TSW at Interface on the card. At thistime, the adjacent node detects AIS signals. (See ① ① ① ① in the figure below.) 2. Line Lo...
ND-70185 (E) CHAPTER 6 Page 137 Revision 3.0 POST INSTALLATION TEST Repair Procedure When LED Indicates Abnormality 2.3 Test Procedure STEP 1: Set the MODE switch to 9 (Fusion Link Test) from 8 (standard setting) on the FCH card and initializethe circuit card by turning the MB switch ON → OFF Figure...
CHAPTER 6 ND-70185 (E) Page 138Revision 3.0 POST INSTALLATION TESTFCCS Network Connection Test Figure 6-7 Fusion Link-Test Results STEP 4: Return Mode to 8 (standard setting) when the test is complete. STEP 5: Initialize the FCH (PA-FCHA) card using the MB switch. Note: Be sure to initialize the FCH...
ND-70185 (E) CHAPTER 6 Page 139 Revision 3.0 POST INSTALLATION TEST FCCS Network Connection Test STEP 4: The call terminates on STN B. STEP 5: Confirm the speech condition is sufficient (no noise, not one-way speech, etc.). STEP 6: Replace the handset of STN A. STEP 7: Repeat the above steps for all...
CHAPTER 6 ND-70185 (E) Page 140Revision 3.0 POST INSTALLATION TESTFCCS Network Connection Test 3.2 ATTCON Connection Test (via FCCS) Perform the ATTCON connection test, using the following procedure. 3.2.1 ATTCON Call Origination Test STEP 1: Dial the operator access code (normally “0”), from STN A ...
ND-70185 (E) CHAPTER 6 Page 141 Revision 3.0 POST INSTALLATION TEST FCCS Network Connection Test 3.3 Line (LC, ELC, DLC Card) Connection Test (via FCCS) Perform the Line (LC, ELC, DLC Card) connection test, following the procedures listed below. 3.3.1 Line Origination Test: Confirmation of Physical/...
CHAPTER 6 ND-70185 (E) Page 142Revision 3.0 POST INSTALLATION TESTFCCS Network Connection Test 3.4 3-party Conference Trunk Function Test (via FCCS) Perform the 3-party conference trunk function test, following the procedures listed below. STEP 1: Using the MBTK Command, make busy all 3-party Confer...
ND-70185 (E) CHAPTER 6 Page 143 Revision 3.0 POST INSTALLATION TEST Fusion and Non-Fusion Connection Tests 3.5.1 Primary Route Trunk Test STEP 1: Using the MBCT command, make busy all trunks in the primary route except the trunk to be tested. STEP 2: Lift the handset of STN A in self-node (Node A). ...
CHAPTER 6 ND-70185 (E) Page 144Revision 3.0 POST INSTALLATION TESTFusion and Non-Fusion Connection Tests 4.1 When Seizing a Trunk from a Station STEP 1: Using the MAT command, make busy all trunks in the route except the trunk to be tested. STEP 2: Station A in self-node (Node A) dials the Physical ...
ND-70185 (E) CHAPTER 6 Page 145 Revision 3.0 POST INSTALLATION TEST SDT Card Loopback Test 5. SDT Card Loopback Test The patterns for loopback test, which can be set by the SDT card, are as follows: 1. Local Loopback Loopback tests are performed only on the SDT card at the self-node. 2. Remote Loopb...
ND-70185 (E) CHAPTER 7 Page 147 Revision 3.0 CHAPTER 7 TROUBLESHOOTING This chapter explains the Fusion-related system messages that may be displayed, together with procedures onhow to repair the indicated failure. If the message is displayed, follow the procedure described in each systemmessage. Fo...
ND-70185 (E) CHAPTER 7 Page 149 Revision 3.0 TROUBLESHOOTING 3-B PM C-level Infinite Loop (Permanent) 2. 3-B PM C-level Infinite Loop (Permanent) This message is displayed when a C-level program abnormal state has been detected as permanent. Whenthe abnormal state is detected by the Port Microproces...
ND-70185 (E) CHAPTER 7 Page 151 Revision 3.0 TROUBLESHOOTING 3-C PM C-level Infinite Loop (Temporary) 3. 3-C PM C-level Infinite Loop (Temporary) This message is displayed when the C-level program has been detected as abnormal by the Port Micropro-cessor (PM) mounted on the FCH (PA-FCHA) card. In th...
CHAPTER 7 ND-70185 (E) Page 152Revision 3.0 TROUBLESHOOTING3-E PM Lockup Failure (Temporary) 4.1 Repair Procedure STEP 1: Make sure that station-to-station connections can be established in the PIM containing the indicated FCH (PA-FCHA) card. If the station-to-station connections cannot be establish...
CHAPTER 7 ND-70185 (E) Page 154Revision 3.0 TROUBLESHOOTING13-H/I/J Signaling Link Failure (Permanent)/(Temporary)/(Recovery) 6.1 Repair Procedure • 13-H (Permanent) STEP 1: Make sure that the front cable is securely inserted. See Figure 7-10 below. Figure 7-10 FCH-DTI Connection STEP 2: Initialize ...
ND-70185 (E) CHAPTER 7 Page 155 Revision 3.0 TROUBLESHOOTING 23-S FCH Failure Notification (Detection) 6.2 Repair Procedure • 13-I (Temporary) STEP 1: Make sure that the front cable is securely inserted. (See Figure 7-10 .) STEP 2: If this message has been displayed once or twice, monitor the failur...
CHAPTER 7 ND-70185 (E) Page 156Revision 3.0 TROUBLESHOOTING23-S FCH Failure Notification (Detection) 7.1 Repair Procedure STEP 1: Make sure that the related Ethernet cables are securely inserted into the connectors. (See the exampleshown below.) If not, securely insert the cable. In this instance, c...
ND-70185 (E) CHAPTER 7 Page 157 Revision 3.0 TROUBLESHOOTING 23-S FCH Failure Notification (Detection) Figure 7-13 How to Check 10 BASE-T Cables WARNING: When a HUB card is placed in make-busy, all BASE-T interfaces connected to theHUB card become inoperative. ATTENTION ContentsStatic SensitiveHandl...
ND-70185 (E) CHAPTER 7 Page 159 Revision 3.0 TROUBLESHOOTING 23-T FCH Fault Notification (Recovery) 8. 23-T FCH Fault Notification (Recovery) This message is displayed when the FCH (PA-FCHA) card that was detected as faulty is recovered. The messageis displayed in the following format. Figure 7-15 2...
CHAPTER 7 ND-70185 (E) Page 160Revision 3.0 TROUBLESHOOTING23-U FCH Status Information 9. 23-U FCH Status Information This message is displayed when the status change of FCH (PA-FCHA) card is detected, which includes “FCHInitial Setting Failure,” “ETHER Transfer Failure.” When this message is displa...
ND-70185 (E) CHAPTER 7 Page 161 Revision 3.0 TROUBLESHOOTING 23-U FCH Status Information 9.1 FLTINF = 00H Initial Setting Failure This message is displayed when the Ethernet Controller Initial Setting ends in failure. The detailed informationis indicated in the following format. Figure 7-17 23-U FCC...
CHAPTER 7 ND-70185 (E) Page 162Revision 3.0 TROUBLESHOOTING23-U FCH Status Information 9.2 FLTINF = 18H Spanning Tree Abnormal Answer This message is displayed when Spanning Tree Abnormal Answer is detected. The detailed information is indi-cated in the following format. Figure 7-18 23-U FCCH Status...
ND-70185 (E) CHAPTER 7 Page 163 Revision 3.0 TROUBLESHOOTING 23-U FCH Status Information 9.2.1 Repair Procedure A Fusion Point Code (FPC) is assigned using the AFPC command. If any FPC data has not been assignedproperly, this message is displayed. Make sure that the indicated FPC data is properly as...
ND-70185 (E) CHAPTER 7 Page 165 Revision 3.0 TROUBLESHOOTING 23-U FCH Status Information 9.4 FLTINF = 1EH Spanning Tree Generation End This message is displayed when Spanning Tree Generation is complete. The detailed information is indicatedin the following format. Figure 7-21 23-U FCCH Status Notif...
CHAPTER 7 ND-70185 (E) Page 166Revision 3.0 TROUBLESHOOTING23-U FCH Status Information 9.5 FLTINF = 1FH Spanning Tree Generation Start This message is displayed when Spanning Tree Generation starts. Figure 7-22 23-U FCCH Status Notification - Spanning Tree Generation 9.6 FLTINF = 85H Checksum Verifi...
ND-70185 (E) CHAPTER 7 Page 167 Revision 3.0 TROUBLESHOOTING 23-W FCH Alternate Routing Start Notification 10. 23-W FCH Alternate Routing Start Notification This message is displayed when the indicated FCH card of self-Node becomes inoperative. This message is alsodisplayed when the card is placed i...
ND-70185 (E) CHAPTER 8 Page 169 Revision 3.0 CHAPTER 8 EX- FCCS 1. General This feature provides the following functions (they are activated when connecting multiple Fusion networks) ora NEAX2000 IVS 2 system to a Fusion Network using the Enhanced CCIS feature. The network connected by EX-FCCS funct...
CHAPTER 8 ND-70185 (E) Page 170Revision 3.0 EX- FCCSEX-FCCS Network Configuration 2. EX-FCCS Network Configuration 2.1 Network Configuration The summary of network configuration classified into two types are shown in Table 8-1 . See Table 8-1 in conjunction with Figure 8-1 for easy understanding of ...
ND-70185 (E) CHAPTER 8 Page 171 Revision 3.0 EX- FCCS EX-FCCS Network Configuration 2.2 Conditions for Network Establishment (NEAX2000 IVS 2 to NEAX2400 IMX Connection) Conditions for connecting the NEAX2000 IVS 2 to NEAX2400 IMX are described below. 1. All IVS 2 systems must be directly connected t...
CHAPTER 8 ND-70185 (E) Page 172Revision 3.0 EX- FCCSEX-FCCS Network Configuration 2.3 Conditions for Network Establishment (NEAX2400 IMX to NEAX2400 IMX Connection) Conditions for establishing a FCCS network (NEAX2400 IMX to NEAX2400 IMX) are shown below. 1. Each Fusion Network can accommodate a max...
ND-70185 (E) CHAPTER 8 Page 173 Revision 3.0 EX- FCCS EX-FCCS Network Configuration 2.4 Fusion Network Group (FUG) [Fusion Network Group (FUG)] When connecting multiple Fusion networks using EX-FCCS, a Fusion Network group number is requiredto distinguish different Fusion Network groups. A Fusion Ne...
CHAPTER 8 ND-70185 (E) Page 174Revision 3.0 EX- FCCSEX-FCCS Network Configuration 2.5 Interactions 1. Conditions for PS Service Roaming and Hand-over feature cannot be activated between FUG-FUG in an EX-FCCS network andFUG-IVS 2 in an Enhanced CCIS network. To execute roaming service, connect other ...
CHAPTER 8 ND-70185 (E) Page 176Revision 3.0 EX- FCCSEX-FCCS Features 3. The node that requires the data programming or data change for Number Portability depends on the pattern. See Figure 8-5 and Table 8-2 that explain the eight patterns. Figure 8-5 Patterns of Number Portability Note 1: Destinatio...
CHAPTER 8 ND-70185 (E) Page 178Revision 3.0 EX- FCCSEX-FCCS Features [Centralized Traffic Collecting] 1. The feature to collect traffic information of NEAX2000 IVS 2 system is activated by logging in to the NEAX2000 IVS 2 node with Centralized-MAT for EX-FCCS using the traffic collecting command ded...
ND-70185 (E) CHAPTER 8 Page 181 Revision 3.0 EX- FCCS EX-FCCS Features 2. Unique PCs (Point Codes) in the CCIS network connected with EX-FCCS are required. Figure 8-7 PC Assignment in EX-FCCS Network 3. The CCH to be used is selected as follows. 1) when the call is processed using the speech line (B...
CHAPTER 8 ND-70185 (E) Page 182Revision 3.0 EX- FCCSEX-FCCS Features 3.4 Centralized Message Center Interface - EX-FCCS This section explains the conditions of Centralized Message Center Interface feature within EX-FCCS Net-work. This feature provides an interface to the external CPU for Message Cen...
CHAPTER 8 ND-70185 (E) Page 184Revision 3.0 EX- FCCSEX-FCCS Features 3.5 Centralized Billing - EX-FCCS (Polling Method) This section explains the conditions of Centralized Billing feature within EX-FCCS Network. • Two methods of administering Centralized Billing information are available: either the...
ND-70185 (E) CHAPTER 8 Page 185 Revision 3.0 EX- FCCS Data Programming 4. Data Programming This section explains how to assign a brand-new EX-FCCS network data. There are some conditions for data programming to be required for EX-FCCS. 1. When connecting a stand-alone NEAX2400 IMX, non-fusion system...
CHAPTER 8 ND-70185 (E) Page 186Revision 3.0 EX- FCCSData Programming 4.1 Brand-new EX-FCCS Network To install EX-FCCS network as a brand-new system between two Fusion Groups (when no CCIS data hasbeen assigned), the overall data programming procedure is as follows. 4.1.1 To Log in to All Nodes in EX...
ND-70185 (E) CHAPTER 8 Page 187 Revision 3.0 EX- FCCS Data Programming STEP 2: ARTD Assign the following three routes for this feature: • Speech Path Route (Traffic Route) • Signaling Route • Dummy Route (Flag Route) Assign each route data in accordance with the table shown below. Note that data ass...
ND-70185 (E) CHAPTER 8 Page 189 Revision 3.0 EX- FCCS Data Programming STEP 7: ACIC1 Assign CSCG for Basic/Primary Route. The odd numbered CSCG for Alternate Route assignment. STEP 8: ACIC2 Assign CICs (Circuit Identification Codes) corresponding to trunk number. Although trunk numberand the CIC may...
ND-70185 (E) CHAPTER 8 Page 191 Revision 3.0 EX- FCCS Data Programming STEP 3: AFUGN Assign EX-FCCS Fusion Group data. Designate Self-FUG Number, Connection FUG Number andFusion Point Code (FPC) of the NCN within each FUG. Either of FUG is set as the Center FUG bychecking the “CENTER” parameter. STE...
CHAPTER 8 ND-70185 (E) Page 192Revision 3.0 EX- FCCSData Programming STEP 5: ARNPL Assign the access code for LCR/LCRS as assigned in ASPAN associated with the logical routes foreach external trunk assigned in ARTD/ARTDN. STEP 6: AMND Assign the Maximum Necessary Digit (MND). Note 1: The MND is the ...
ND-70185 (E) CHAPTER 8 Page 193 Revision 3.0 EX- FCCS Data Programming 4.2 Upgrading CCIS Network to EX-FCCS Network This section explains the way to assign the data when upgrading a CCIS Network to an EX-FCCS Network.Perform the necessary data programming using the following upgrading patterns: • U...
CHAPTER 8 ND-70185 (E) Page 194Revision 3.0 EX- FCCSData Programming 1. To Log-in to All Nodes in EX-FCCS Network Perform the following data programming at each NCN of all the Fusion Groups. STEP 1: AFUGN Assign EX-FCCS Fusion Group data. Designate Self FUG Number, connection FUG Number andFusion Po...
ND-70185 (E) CHAPTER 8 Page 195 Revision 3.0 EX- FCCS Data Programming 4.2.2 Upgrading CCIS between FUG and IVS2 System to Enhanced CCIS Network 1. To Log-in to All Nodes in EX-FCCS Network Assign the following data at the NCN of FUG with Centralized MAT for Fusion. STEP 1: AFUGN Assign EX-FCCS Fusi...
CHAPTER 8 ND-70185 (E) Page 196Revision 3.0 EX- FCCSData Programming 2. To Access EX-FCCS Trunk via EX-FCCS Telephone Number Assign the following data at NCN of the FUG. STEP 1: AEADN Assign the ADC (Abbreviate Digit Code) for connection Fusion Group. Enter the FUG Number as-signed by AFUGN command,...
ND-70185 (E) CHAPTER 8 Page 197 Revision 3.0 EX- FCCS Data Programming 1. To Log-in to All Nodes in EX-FCCS Network To upgrade CCIS network to EX-FCCS Network as shown in the figure on the previous page, all the IMX sys-tems are set as NCNs respectively. To construct a EX-FCCS Network including stan...
NEC Manuals
-
NEC nec
Manual
-
NEC LCD172VXM
Manual
- NEC IP8800/S6600 Manual
-
NEC PSIII
Manual
-
NEC XV17+
Manual
-
NEC LCD1860NX
Manual
-
NEC PA322UHD
Manual
-
NEC Versa M540
Manual
-
NEC LCD224WMX
Manual
-
NEC SP4620
Manual
-
NEC 0612-20
Manual
-
NEC PX-50XM5A
Manual
-
NEC 46 V462
Manual
-
NEC MT1055
Manual
-
NEC PD75402A
Manual
-
NEC NP-V311X
Manual
-
NEC LT240K, LT260K
Manual
-
NEC DTR-IR-2
Manual
-
NEC j
Manual
-
NEC PD78052(A)
Manual