Page 2 - LIABILITY DISCLAIMER; NEAX and D; are registered trademarks of NEC Corporation.
LIABILITY DISCLAIMER NEC America Inc. reserves the right to change the specifications,functions, or features, at any time, without notice. NEC America Inc. has prepared this document for use by its em-ployees and customers. The information contained herein is theproperty of NEC America Inc. and shal...
Page 3 - ISSUE 2; Remote PIM System Manual; Page; iii; TABLE OF CONTENTS; CHAPTER 1
ND-46550 (E) ISSUE 2 SEPTEMBER, 1998 NEAX2000 IVS Remote PIM System Manual TABLE OF CONTENTS Page LIST OF FIGURES............................................................................................................................................. iii LIST OF TABLES .............................
Page 4 - CHAPTER 4
TABLE OF CONTENTS ND-46550 (E) Page iiRevision 2.0 TABLE OF CONTENTS (CONTINUED) Page 2.2.6 Mounting of Line/Trunk Card on Small Platform PIM ................................................................ 45 2.2.7 Mounting of Line/Trunk Card on 1000 IVS PIM ...........................................
Page 5 - LIST OF FIGURES; Figure
ND-46550 (E) LIST OF FIGURES Page iii Revision 2.0 LIST OF FIGURES Figure Title Page 2-1 Remote PIM System Outline .............................................................................................................. 3 2-2 System Configuration ..................................................
Page 7 - LIST OF TABLES; Table
ND-46550 (E) LIST OF TABLES Page v Revision 2.0 LIST OF TABLES Table Title Page 2-1 PIM Configuration ............................................................................................................................... 4 2-2 Required Equipment ................................................
Page 8 - This page is for your notes.
LIST OF TABLES ND-46550 (E) Page viRevision 2.0 This page is for your notes.
Page 9 - OUTLINE OF THIS MANUAL
ND-46550 (E) CHAPTER 1 Page 1 Revision 2.0 CHAPTER 1 INTRODUCTION 1. OUTLINE OF THIS MANUAL This manual provides the system description and installation procedure for providing the Remote PIM System tothe NEAX2000 IVS. 2. REFERENCE MANUALS Refer to the following manuals for additional information on...
Page 11 - CHAPTER; CHAPTER 2; SYSTEM OUTLINE; shows an outline of the Remote PIM System.; Figure 2-1 Remote PIM System Outline
ND-46550 (E) CHAPTER 2 Page 3 Revision 2.0 CHAPTER 2 SYSTEM DESCRIPTION 1. SYSTEM OUTLINE Remote PIMs can be installed separately in the same building or between the offices via the Public SwitchingTelephone Network (PSTN). The customers in the remote site can use the same service features as in the...
Page 12 - PIM CONFIGURATION; shows the available PIM configuration for; Table 2-1 PIM Configuration; NUMBER OF PIM AT MAIN SITE
CHAPTER 2 ND-46550 (E) Page 4Revision 2.0 2. PIM CONFIGURATION One PIM can be installed respectively as a remote site. A maximum of 3 remote sites can be provided. The numberof remote sites determines the number of PIMs in one system. Table 2-1 shows the available PIM configuration for the Remote PI...
Page 13 - SYSTEM CONFIGURATION; shows the system configuration.; Figure 2-2 System Configuration
ND-46550 (E) CHAPTER 2 Page 5 Revision 2.0 3. SYSTEM CONFIGURATION Figure 2-2 shows the system configuration. Figure 2-2 System Configuration TDSW DAIA 1 (FP1) DAIC 1 DAIC 2 DAIB (FP1) DAIC 1 DAIC 2 DAIA 2 (FP2) DAIC 3 DAIC 4 DAIB (FP2) DAIC 3 DAIC 4 DAIA 3 (FP3) DAIC 5 DAIC 6 FP0 MP DAIB (FP3) DAIC...
Page 14 - REQUIRED EQUIPMENT; EQUIPMENT NAME; Interface card for Remote PIM System at main site
CHAPTER 2 ND-46550 (E) Page 6Revision 2.0 4. REQUIRED EQUIPMENT Table 2-2 shows the required equipment for establishing the Remote PIM System. Table 2-2 Required Equipment EQUIPMENT NAME DESCRIPTION SN1308 PIM P-A (PIM Q-UA) Port Interface Module for Small Platform System/Remote PIM system (remote s...
Page 15 - Firmware processor card
ND-46550 (E) CHAPTER 2 Page 7 Revision 2.0 PN-DAIC (DAIC Card) Digital Interface Channel Expansion Card.This card provides the 1.5Mbps (24 channel) digital interface.1 through 6 DAIC cards can be provided at main site.In Remote PIM, 2 DAIC cards can be provided. Small Platform PIM: up to 64 line/tru...
Page 16 - SYSTEM CAPACITY; port is used for the control signaling channel.; Table 2-3 System Capacity
CHAPTER 2 ND-46550 (E) Page 8Revision 2.0 5. SYSTEM CAPACITY Table 2-3 shows the system capacity. Note 1: 1 port is used for the control signaling channel. Note 2: This number refers to the maximum number of remote offices. The remote office can have only one re-mote PIM. Note 3: When the main site ...
Page 17 - SYSTEM CONDITIONS; A maximum of 23 lines/trunks can be accommodated in one Remote PIM.
ND-46550 (E) CHAPTER 2 Page 9 Revision 2.0 6. SYSTEM CONDITIONS For providing the Remote PIM System to the NEAX2000 IVS, observe the following conditions: (1) The main site must be the NEAX2000 IVS. The Small Platform System cannot be the main site. The mainsite must be a medium platform (320 ports)...
Page 18 - TIME SLOT ALLOCATION; Figure 2-3 Time Slot Allocation; The control signalling channel is set by SW2 of DAIA/DAIB. Refer to
CHAPTER 2 ND-46550 (E) Page 10Revision 2.0 7. TIME SLOT ALLOCATION One time slot of the last 24 time slots provided by the DAIA-DAIB connection is used for the control signalingchannels. Figure 2-3 shows an example of time slot allocation when mounting 8 port cards to the Small Platform PIM. Figure ...
Page 19 - Chapter 3
ND-46550 (E) CHAPTER 2 Page 11 Revision 2.0 Figure 2-4 Time Slot Allocation (Continued) LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 DAIC 0 DAIC 1 DAIB DAIC 0 DAIC 1 DAIA TDSW • 23 time slots for Line/Trunks • 1 time slot for control signaling channel Note • 24 time slots for Line/Trunks •...
Page 21 - CHAPTER 3; PRECAUTION IN HANDLING; illustrates; Figure 3-1 Static Electricity Guard
ND-46550 (E) CHAPTER 3 Page 13 Revision 2.0 CHAPTER 3 INSTALLATION 1. PRECAUTION IN HANDLING When handling cards, the installer must wear a grounded wrist strap to protect the circuit card from staticelectricity, and the installer must engage in the work on a grounded conductive work surface. Figure...
Page 22 - The symbol shown in; Figure 3-2 Static-Sensitive Attention Symbol; ATTENTION
CHAPTER 3 ND-46550 (E) Page 14Revision 2.0 Figure 3-1 Static Electricity Guard (Continued) The symbol shown in Figure 3-2 designates procedures in which circuit cards are handled. When engaging in such work, the installer must be careful not to cause damage by static electricity. Figure 3-2 Static-S...
Page 23 - CAUTION
ND-46550 (E) CHAPTER 3 Page 15 Revision 2.0 When plugging or unplugging the circuit card, always hold the circuit card by its edge. If you touch another area,you may be exposed to hazardous voltages. CAUTION CARD FRONT Never touch components or soldered surface with bare hands. PBX
Page 24 - INSTALLATION PROCEDURE; and; Figure 3-3 Installation Procedure for Main Site
CHAPTER 3 ND-46550 (E) Page 16Revision 2.0 2. INSTALLATION PROCEDURE Install the Remote PIM System according to the following procedure. Figure 3-3 and Figure 3-4 show the installation procedure for the main site and the remote site. Figure 3-3 Installation Procedure for Main Site Switch Setting of ...
Page 26 - Installation Procedure for Main Site
CHAPTER 3 ND-46550 (E) Page 18Revision 2.0 2.1 Installation Procedure for Main Site 2.1.1 Switch Setting of DAIA Card (1) Location of Lamps, Switches, and Connectors (see Figure 3-5 ) Figure 3-5 PN-DAIA Card ATTENTION ContentsStatic Sensitive HandlingPrecautions Required BUS CN SENSE RUN MB SW1 PCM1...
Page 27 - Table 3-1 Lamp Indications on PN-DAIA Card; LAMP NAME
ND-46550 (E) CHAPTER 3 Page 19 Revision 2.0 (2) Lamp Indications (see Table 3-1 ) Table 3-1 Lamp Indications on PN-DAIA Card LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. LINK Green Lights when a link between this card and a distant office is connected ...
Page 28 - Table 3-2 Switch Settings on PN-DAIA Card; OFF; OFF
CHAPTER 3 ND-46550 (E) Page 20Revision 2.0 (3) Switch Settings In Table 3-2 , the figure in the SWITCH NAME column and the position in in the SETTING POSI- TION column indicate the standard setting of the switch. When the switch is not set as shown by the figureand , the setting of the switch varies...
Page 30 - Set the groove on the switch knob to the desired switch position.
CHAPTER 3 ND-46550 (E) Page 22Revision 2.0 Note 1: Set the groove on the switch knob to the desired switch position. Note 2: Since DAIA card acts like an FP, the SW1 for DAIA in FPs cannot be set to the same number. Note 3: When power is on, flip MB switch to ON (UP position) before plugging/unplugg...
Page 31 - STEP 1: Set MB switch on the DAIA card to up position.; Figure 3-6 Mounting Location of DAIA Card
ND-46550 (E) CHAPTER 3 Page 23 Revision 2.0 2.1.2 Mounting of DAIA Card STEP 1: Set MB switch on the DAIA card to up position. STEP 2: Mount DAIA card in the AP slots (AP0-AP7) on the Main Site PIM0-PIM5. A maximum of three DAIA cards can be mounted. Figure 3-6 shows the mounting location of the DAI...
Page 36 - STEP 1: Set MB switch on the DAIC card to up position.
CHAPTER 3 ND-46550 (E) Page 28Revision 2.0 2.1.4 Mounting of DAIC Card STEP 1: Set MB switch on the DAIC card to up position. STEP 2: Mount DAIC card in the AP slots (AP0-AP7) to the LT slot (LT09) on the Main Site PIM0-PIM5.A maximum of six DAIC cards can be mounted.After mounting the card, set MB ...
Page 37 - Cable connection between BUS Card and the DAIA Card
ND-46550 (E) CHAPTER 3 Page 29 Revision 2.0 2.1.5 BUS Cable Connection (1) Cable connection between BUS Card and the DAIA Card Connect the DAIA card to the BUS card by the RMT PCM-0.3 CA and 17-TW-0.3 CONN CA-A, as shown in Figure 3-9 . Note: Up to three DAIA cards can be connected directly by a dai...
Page 38 - Cable Connection between DAIA Card and DAIC Card; Figure 3-10 DAIA-DAIC Cable Connection
CHAPTER 3 ND-46550 (E) Page 30Revision 2.0 (2) Cable Connection between DAIA Card and DAIC Card Connect the DAIC card to the DAIA card by the 48-TW-0.2 CONN CA, as shown in Figure 3-10 . Figure 3-10 DAIA-DAIC Cable Connection (1) 1-PIM Configuration : RMT PCM-0.3 CA : 17-TW-0.3 CONN CA-A DAIC BUS • ...
Page 42 - Installation Procedure for Remote Site
CHAPTER 3 ND-46550 (E) Page 34Revision 2.0 2.2 Installation Procedure for Remote Site 2.2.1 Switch Setting of DAIB Card (1) Location of Lamps, Switches, and Connectors (see Figure 3-14 ) Figure 3-14 PN-DAIB Card ATTENTION ContentsStatic Sensitive HandlingPrecautions Required BUS CN SENSE RUN MB SW1 ...
Page 43 - Table 3-6 Lamp Indications on PN-DAIB Card
ND-46550 (E) CHAPTER 3 Page 35 Revision 2.0 (2) Lamp Indications (see Table 3-6 ) Table 3-6 Lamp Indications on PN-DAIB Card LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. LINK Green Lights when a link between this card and a distant office is connected ...
Page 44 - Table 3-7 Switch Settings on PN-DAIB Card
CHAPTER 3 ND-46550 (E) Page 36Revision 2.0 (3) Switch Settings In Table 3-7 , the figure in the SWITCH NAME column and the position in in the SETTING POSI- TION column indicate the standard setting of the switch. When the switch is not set as shown by the figureand , the setting of the switch varies...
Page 47 - STEP 1: Set MB switch on the DAIB card to up position.; Figure 3-15 Mounting Location of DAIB Card
ND-46550 (E) CHAPTER 3 Page 39 Revision 2.0 2.2.2 Mounting of DAIB Card STEP 1: Set MB switch on the DAIB card to up position. STEP 2: Mount DAIB card in the MP slot on the Remote PIM. STEP 3: After mounting the card, set MB switch to down position. Figure 3-15 Mounting Location of DAIB Card ATTENTI...
Page 53 - REMOTE PIM TYPE; Small Platform; The CSI card can not be used on the Remote PIM.
ND-46550 (E) CHAPTER 3 Page 45 Revision 2.0 2.2.6 Mounting of Line/Trunk Card on Small Platform PIM Mount the Line/Trunk cards in the following slots on the Remote PIM. Connect the line cables referring to Figure 3-21 through Figure 3-23 and Table 3-8 . Figure 3-21 Mounting Location of Line/Trunk Ca...
Page 54 - A maximum of 64 line/trunks can be accommodated in one Remote PIM.
CHAPTER 3 ND-46550 (E) Page 46Revision 2.0 Figure 3-22 Location of Each LEN (Small Platform) 01350134013301320131013001290128 01430142014101400139013801370136 01510150014901480147014601450144 01590158015701560155015401530152 01670166016501640163016201610160 01750174017301720171017001690168 018301820...
Page 57 - A maximum of 44 line/trunks can be accommodated in one Remote PIM.
ND-46550 (E) CHAPTER 3 Page 49 Revision 2.0 Figure 3-25 Location of Each LEN (1000 IVS) 01910190018901880187018601850184 01350134013301320131013001290128 01430142014101400139013801370136 01510150014901480147014601450144 01590158015701560155015401530152 0159015801570156 016701660165016401630162016101...
Page 59 - through; Figure 3-27 Mounting Location of Line/Trunk Card; Table 3-10 LTC Connector Accommodation; The CSI card cannot be used on the Remote PIM.
ND-46550 (E) CHAPTER 3 Page 51 Revision 2.0 2.2.8 Mounting of Line/Trunk Card on PIM N - UB (64 port PIM) Mounting of Line/Trunk cards in the slots on the Remote PIM. Connect the line cables referring to Figure 3-27 through Figure 3-29 and Table 3-10 . Figure 3-27 Mounting Location of Line/Trunk Car...
Page 60 - A maximum of 60 line/trunks can be accommodated in one Remote PIM.
CHAPTER 3 ND-46550 (E) Page 52Revision 2.0 Figure 3-28 Location of Each LEN (PIM N_UB) • When opposite DAIA card is set to FP No.1: 0131 0135 0139 0143 0147 0151 0155 0159 0193 0167 0171 0175 0179 0183 0187 0191 0130 0134 0138 0142 0146 0150 0154 0158 0162 0166 0170 0174 0178 0182 0186 0190 0129 013...
Page 62 - When using PN-AUCA card
CHAPTER 3 ND-46550 (E) Page 54Revision 2.0 2.2.9 Power Failure Transfer (PFT) The PN-AUCA card or the PZ-8PFTA card can be used as the PFT card at the remote site. (1) When using PN-AUCA card • Figure 3-30 shows an outline of a PFT (PN-AUCA) connection. • Figure 3-31 shows the MDF cross connection f...
Page 64 - When using PZ-8PFTA card at a remote site; Note
CHAPTER 3 ND-46550 (E) Page 56Revision 2.0 Figure 3-31 MDF Cross Connection for PFT (PN-AUCA) (Continued) Note 1: The No. 2 and No. 3 circuits in the PN-4COT card cannot be used with the PFT function. Note 2: When using Ground Start trunks with the PFT function, the single line stations must have a ...
Page 65 - card as shown in
ND-46550 (E) CHAPTER 3 Page 57 Revision 2.0 • Install the PZ-8PFTA card to the PIM according to the following steps. STEP 1: Connect the champ connectors of 25-pair cables to the PFT0 and PFT1 connectors on the PZ-8PFTA card as shown in Figure 3-33 . Then, secure them to each other using screws and ...
Page 66 - and SPL washers, as shown in; Figure 3-34 Mounting PZ-8PFTA Card to PIM
CHAPTER 3 ND-46550 (E) Page 58Revision 2.0 STEP 2: Hook the PZ-8PFTA card at the front bracket on the PIM, and secure them to each other using screws and SPL washers, as shown in Figure 3-34 . Figure 3-34 Mounting PZ-8PFTA Card to PIM SPL WASHER SCREW PZ-8PFTA PIM + + + +
Page 67 - STEP 3: Connect the 25-pair cables on the MDF referring to; Figure 3-35 PFT Connector Pin Assignment
ND-46550 (E) CHAPTER 3 Page 59 Revision 2.0 STEP 3: Connect the 25-pair cables on the MDF referring to Figure 3-35 and Figure 3-36 . • Figure 3-35 shows the PFT connector pin assignment for each PFT circuit number (No. 0 - No. 7). Figure 3-35 PFT Connector Pin Assignment PFT0 PFT0 26 Sta. T0 1 Sta. ...
Page 70 - Connection Between Main Site and Remote Site; When using the LTC connector on BWB; Figure 3-37 DTI Cable Connection via LTC Connector
CHAPTER 3 ND-46550 (E) Page 62Revision 2.0 2.3 Connection Between Main Site and Remote Site 2.3.1 DTI Connection at Main Site (1) When using the LTC connector on BWB Connect the cable to a CSU or directly to the Remote PIM via the MDF as shown in Figure 3-37 . Figure 3- 38 shows an example of cable ...
Page 72 - When using CN connector on DAIA Card; Figure 3-39 DTI Cable Connection via CN Connector (Main Site)
CHAPTER 3 ND-46550 (E) Page 64Revision 2.0 (2) When using CN connector on DAIA Card Connect the cable to a CSU or directly to the Remote PIM via the CN connector on the DAIA/DAIC card asshown in Figure 3-39 . Connection of DAIC cards between the Main PIM and the Remote PIM is available in the same m...
Page 74 - MP Reset
CHAPTER 3 ND-46550 (E) Page 66Revision 2.0 2.4 MP Reset After mounting all DAIC cards and connecting between the main site and the remote site, press the SW1 switch onthe MP card.
Page 75 - Table 4-1 Remedial Action on Each Lamp Status; CARD NAME
ND-46550 (E) CHAPTER 4 Page 67 Revision 2.0 CHAPTER 4 TROUBLESHOOTING This chapter describes the method for fault diagnosis and troubleshooting when maintenance personnel detectedthe fault occurrence by lamp indication on DAIA, DAIB, and DAIC cards. For other system faults, refer to theMaintenance M...