Page 2 - Leica DISTO; Table of Contents
Leica DISTO TM E7300 788218a 1 EN Table of Contents Instrument Set-up - - - - - - - - - - - - - - - - - - - - - - - - - - 2 Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2Display - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2Inser...
Page 3 - Overview
Leica DISTO TM E7300 788218a 2 EN Instrument Set-up Overview The safety instructions and the user manual should be read through carefully before the product is used for the first time. The person responsible for the product must ensure that all users understand these directions and adhere to them. D...
Page 4 - Operations; Clear; ON; InFo; Adjusting measuring reference; ously
Leica DISTO TM E7300 788218a 3 EN Operations Switching ON/OFF Clear Message Codes ON OFF 2 sec Device is turned OFF. i Press ON button 2 sec to start continuous laser mode. 1x Undo last action. 2x Leave actual func-tion, go to default operation mode. If the message " InFo " appears with a nu...
Page 5 - Keypad lock ON; PRESS; within
Leica DISTO TM E7300 788218a 4 EN Operations Beep ON/OFF Illumination ON/OFF 2 sec simultane- ously 2 sec simultane- ously Keypad lock ON Keypad lock OFF 2 sec simultane- ously PRESS MINUS 1 within 2 sec 2
Page 6 - Measuring Functions; Measuring single distance; Aim active laser at target.
Leica DISTO TM E7300 788218a 5 EN Measuring Functions Measuring single distance 1 Aim active laser at target. 2 8.532 m 3 i Target surfaces: Measuring errors can occur when measuring to colourless liquids, glass, styrofoam or semi-permaeble surfaces or when aiming at high gloss surfaces. Against dar...
Page 7 - Area; simultaneously; Memory is completely deleted.
Leica DISTO TM E7300 788218a 6 EN Measuring Functions Area 1 1x 2 Aim laser at first target point. 3 4 Aim laser at sec-ond target point. 24.352 m 2 5 i The result is shown in the main line and the measured value above. Partial Measurements: Press + or - after starting the first measurement. Measure...
Page 8 - Aim laser at lower point.
Leica DISTO TM E7300 788218a 7 EN Measuring Functions Pythagoras (2-point) 1 4x 2 Aim laser at upper point. 3 4 Aim laser rectan-gular at lower point. 8.294 m 5 i The result is shown in the main line and the measured distance above. Pressing the measuring key for 2 sec in the func-tion activates aut...
Page 9 - Stake out
Leica DISTO TM E7300 788218a 8 EN Measuring Functions Stake out 1 2 3 1.000 m 1 6x 0.625 m 2 Adjust value. 3 Approve value and start measurement. 4 Move device slowly along the stake-out line. The distance to the next stake out point is displayed. 0.625 m 0.240 m 0.240 m is missing up to next 0.625 ...
Page 10 - Technical Data; If the message; Error; does not disappear; appears with a number,
Leica DISTO TM E7300 788218a 9 EN Technical Data * applies for 100 % target reflectivity (white painted wall), low ambient light, 25 ºC** applies for 10 to 500 % target reflectivity, high ambient light, - 10 ºC to + 50 ºC*** Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The ma...
Page 11 - Care; Warranty; Symbols used; Permitted use
Leica DISTO TM E7300 788218a 10 EN Care • Clean the device with a damp, soft cloth. • Never immerse the device in water. • Never use aggressive cleaning agents or solvents. Disposal CAUTION Flat batteries must not be disposed of with household waste. Care for the environment and take them to the c...
Page 12 - Safety Instructions; Hazards in use; Limits of use
Leica DISTO TM E7300 788218a 11 EN Safety Instructions Hazards in use WARNING Watch out for erroneous measurements if the instrument is defective or if it has been dropped or has been misused or modified. Carry out periodic test measurements, particularly after the instrument has been subject to a...
Page 13 - Reorient or relocate the receiving antenna.; Laser classification; Laser Class 2 products:; Labelling
Leica DISTO TM E7300 788218a 12 EN Safety Instructions FCC statement (applicable in U.S.) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reason-able protection against harmful...