Page 2 - Keypad
2 Keypad DISTO classic 5 1.2.0 en de en fr it es pt nl da sv no fi jp zh ko pl hr hu ru cz el Keypad D5-Z1 Display D5-Z2 1 Laser "on" 2 Measurement reference (front/ stand/ rear) 3 Information 4 Display of the mathematical signs/operations 5 Main display (e.g. measured distance) 6 Distance m...
Page 3 - How to Use the Instrument; Inserting / replacing the batteries
3 How to Use the Instrument DISTO classic 5 1.2.0 en de en fr it es pt nl da sv no fi jp zh ko pl hr hu ru cz el How to Use the Instrument Inserting / replacing the batteries 1 Depress the locking clip and slide end piece to the right. D5-Z3 2 Remove battery cover. Replace batteries. Appears on the ...
Page 4 - Reference setting; Possible settings; Measuring; Distance measurement; Measuring from flat planes
4 How to Use the Instrument DISTO classic 5 1.2.0 en de en fr it es pt nl da sv no fi jp zh ko pl hr hu ru cz el Reference setting Press until desired reference setting appears. Possible settings D5-Z4 front stand rear ) At the back of the instrument is a 1/4" camera thread for the stand. ) Chan...
Page 5 - Laser in continous operation; Calculations; Area; Volume
5 How to Use the Instrument DISTO classic 5 1.2.0 en de en fr it es pt nl da sv no fi jp zh ko pl hr hu ru cz el Laser in continous operation Press until a long "beep" is heard. Now the laser is activated permanently.A distance measurement is triggered each time the key is pressed.Press to e...
Page 6 - Selecting units
6 How to Use the Instrument DISTO classic 5 1.2.0 en de en fr it es pt nl da sv no fi jp zh ko pl hr hu ru cz el Menu/ Settings With this menu settings on the user level are possible. The user can configure the instrument to his/her own specific and personal needs. D5-Z9 1 Measure with offset (add/r...
Page 7 - Resetting; Functions; Recalling the constant
7 Functions DISTO classic 5 1.2.0 en de en fr it es pt nl da sv no fi jp zh ko pl hr hu ru cz el ) After making/changing settings, it is imperative that a test measurement is performed. Resetting Call up menu point. starts blinking on the display. With key [+ / -] select components to be reset. To c...
Page 8 - Partial heights, partial distances
8 Functions DISTO classic 5 1.2.0 en de en fr it es pt nl da sv no fi jp zh ko pl hr hu ru cz el Tracking - Minimum D5-Z11 Determine the minimum dimension, e.g. ceiling height, without having to precisely align to the normal. Press until appears on the display. Aim DISTO approximately at the target ...
Page 9 - Multiplication; Doubling a measured value
9 Functions DISTO classic 5 1.2.0 en de en fr it es pt nl da sv no fi jp zh ko pl hr hu ru cz el Multiplication Make measurement (e.g. 8.375m).Multiplication by pressing [ x ] key.Additional measurements (e.g. 8.375m). = Area (e.g. 29.313m²) ) The volume can be calculated by an additional multiplica...
Page 10 - Determination with two points; Detemination with 3 points
10 Functions DISTO classic 5 1.2.0 en de en fr it es pt nl da sv no fi jp zh ko pl hr hu ru cz el Determination with two points For estimating the height/ width of buildings. Very useful for making measure-ments from standing position (no bending) if the height is determined with two or three distan...
Page 11 - User Information; Range; Rough surfaces
11 User Information DISTO classic 5 1.2.0 en de en fr it es pt nl da sv no fi jp zh ko pl hr hu ru cz el Determination of a partial height with 3 points Height determination between point 1 and point 2 with three measured points. Press until appears on the display; laser is activated and"1 ---...
Page 12 - Inclined, round surfaces; Safety Instructions; Use of the instrument; Permitted use
12 Safety Instructions DISTO classic 5 1.2.0 en de en fr it es pt nl da sv no fi jp zh ko pl hr hu ru cz el ) When aiming through panes of glass, of if there are several objects in the line-of-sight erroneous measure-ments can occur. Wet, smooth or high-gloss surfaces 1 Aiming at a "Acute" a...
Page 13 - Limits of use
13 Safety Instructions DISTO classic 5 1.2.0 en de en fr it es pt nl da sv no fi jp zh ko pl hr hu ru cz el • Opening of the equipment by using tools (screwdrivers, etc.), as far as not specifically permitted for certain cases • Carrying out modification or conversion of the product • Use after misa...
Page 14 - Hazards in use; Important hazards in use
14 Safety Instructions DISTO classic 5 1.2.0 en de en fr it es pt nl da sv no fi jp zh ko pl hr hu ru cz el Hazards in use Important hazards in use WARNING: The absence of instruction, or the inadequate imparting of instruction, can lead to incorrect or prohibited use, and can give rise to accidents...
Page 15 - Laser classification
15 Safety Instructions DISTO classic 5 1.2.0 en de en fr it es pt nl da sv no fi jp zh ko pl hr hu ru cz el Laser classification The DISTO produces a visible laser beam which emerges from the front of the instrument.It is a Class 2 laser product in accordance with:• IEC60825-1 : 1993 "Radiation ...
Page 17 - Labelling
17 Safety Instructions DISTO classic 5 1.2.0 en de en fr it es pt nl da sv no fi jp zh ko pl hr hu ru cz el Labelling D5-Z14 D5-Z15 D5-Z16 D5-Z17 D5-Z18 CAUTION: Allow only authorized Leica Geosystems service workshops to service the instruments. Maximum radiant power: 0.95mW Emitted wavelength: 620...
Page 18 - Technical Data; Message Codes; Error message
18 Technical Data DISTO classic 5 1.2.0 en de en fr it es pt nl da sv no fi jp zh ko pl hr hu ru cz el Technical Data All rights reserved to make technical changes. * Display unit as off 100m : 1 cm ** At long range ± 5 ppm (± 0,5mm/ 100 m) plus short range error. Message Codes Error message appears...