Page 2 - Chapter overview
Leica DM 500, DM500 B Manual 2 Chapter overview Safety regulations 4 The Leica DM500 , DM500 B 15 Get Ready! 18 Get Set! 25 Go! 34 Care of the Microscope 36 Dimensions 39
Page 3 - Contents
Leica DM 500, DM500 B Manual 3 Contents Safety regulations 4 Safety concept 5 Symbols used in this operating manual 6 Important Notes 7 Instructions on use 8 Health risks and dangers of use 10 Information for the person responsible for the instrument 11 Care instructions 12 Accessories, maintenance ...
Page 5 - Safety concept
Leica DM 500, DM500 B Manual 5 Safety concept The individual modules of the Leica DM micros-copy series include an interactive CD-ROM with all relevant user manuals several languages. Keep it in a safe place, and readily accessible to the user. User manuals and updates are also available for you to ...
Page 6 - Symbols used in this operating manual
Leica DM 500, DM500 B Manual 6 Symbols used in this operating manual Warning of a danger • This symbol indicates especially impor-tant information that must be read and complied with. Failure to comply can cause the following: Ϙ Hazards to personnel Ϙ Functional disturbances or damaged instru-ments...
Page 7 - Important Notes
Leica DM 500, DM500 B Manual 7 Important Notes Description The Leica DM500 and DM500 B microscope meets today's state of the art of technology. Neverthe-less, hazards may still arise during operation. The potential risks are described below. • Before installing, operating or using the instruments, ...
Page 8 - Instructions on use
Leica DM 500, DM500 B Manual 8 Instructions on use Intended use The Leica DM500 and DM500 B microscopes are optical instrument which use magnification and illumination to improve the visibility of objects. It is used for observing and documenting. The Leica DM500 and DM500 B microscopes may be used ...
Page 10 - Health risks and dangers of use
Leica DM 500, DM500 B Manual 10 Health risks and dangers of use Health risks Workplaces with microscopes facilitate and improve the viewing task, but they also impose high demands on the eyes and holding muscles of the user. Depending on the duration of uninterrupted work, asthenopia and musculosk...
Page 11 - Information for the person responsible for the instrument
Leica DM 500, DM500 B Manual 11 Information for the person responsible for the instrument Information for the person responsible for the instrument Ϙ Ensure that the Leica DM500 or DM500 B microscope is used only by qualified person-nel. Ϙ Ensure that this user manual is always avail-able at the Lei...
Page 12 - Care instructions
Leica DM 500, DM500 B Manual 12 Care instructions General instructions Ϙ Protect the Leica DM500 or DM500 B micro-scope against damp, vapors, acids, alkalis, and corrosive substances. Do not store chemicals in the vicinity. Ϙ Protect the Leica DM500 or DM500 B micro-scope from oil and grease. Never ...
Page 13 - Accessories, maintenance and repair
Leica DM 500, DM500 B Manual 13 Accessories, maintenance and repair Accessories Only the following accessories may be used with the Leica DM500 or DM500 B microscope: Ϙ The Leica accessories described in this user manual. Ϙ Other accessories, provided that these have been expressly approved by Leica...
Page 14 - Electrical data and ambient conditions
Leica DM 500, DM500 B Manual 14 Electrical data and ambient conditions Environment Temperature for use +10 °C … +40 °C Storage temperature -20 °C … +52 °C +50 °F … +104 °F Manipulation shock 25 mm on 50 mm hard wood Transport shock (unpacked) 100 g / 6 ms Transport shock (packed) 800 mm free fall Tr...
Page 17 - Unpacking
Leica DM 500, DM500 B Manual 17 Unpacking Ϙ Carefully remove the microscope and any components from the packing carton. Ϙ Check the components against the planned configuration. Ϙ Optional items such as contrast accessories, camera adapters, cameras, and carrying cases are not shipped as part of the...
Page 19 - Attaching the viewing Tubes
Leica DM 500, DM500 B Manual 19 Tools used Ϙ Allen key There are two types of viewing tube. Identify which viewing tube you have: Type 1: Leica EZ viewing tube with integrated eyepieces. Type 2: Standard viewing tube with separate eyepieces 1. Slightly unscrew the set screw (located on top of the ...
Page 20 - Leica EZ Viewing Tube – integrated eyepieces
Leica DM 500, DM500 B Manual 20 2. Position the Leica EZ viewing tube back in place on the stand. 3. Attach the captive thumbscrew using the wrench tool that comes with the captive thumbscrew. Leica EZ Viewing Tube – integrated eyepieces To rotate the Leica EZ viewing tube, either loosen the set s...
Page 22 - Leica Standard Viewing Tube – separated eyepieces
Leica DM 500, DM500 B Manual 22 Leica Standard Viewing Tube – separated eyepieces 2. Lock the eyepieces into the eyetubes by tightening the silver screws on the under-side of the eyetubes with a standard Cross type (Phillips) screwdriver (not provided). The eyepieces will still rotate, but they wi...
Page 23 - Eyeguards
Leica DM 500, DM500 B Manual 23 If you wear eyeglasses for microscope viewing, keep the rubber eyeguards folded down. If you do not wear eyeglasses, you may find it useful to unfold the rubber eyeguards in order to help block out ambient room light. Eyeguards If you have purchased a standard mic...
Page 24 - Installing Objectives and Substage Condenser
Leica DM 500, DM500 B Manual 24 Installing Objectives • Always rotate the nosepiece by using the knurled nosepiece ring. 1. As you rotate the nosepiece clockwise, attach the objectives by screwing them into the nosepiece holes starting with the lowest magnification and advancing to the highest magn...
Page 26 - Turning on the microscope
Leica DM 500, DM500 B Manual 26 Turning on the microscope As a safety precaution, the power cord has been grounded to the microscope base. Never use an adapter between the power cord and the power source; it will render the grounding feature ineffective. Work Surface • Always use your microscope ...
Page 27 - Using the Condenser
Leica DM 500, DM500 B Manual 27 Plug in and Turn on the Microscope 1. Plug the microscope power cord into a suit- able grounded electrical outlet. A grounded 3-wire cord is provided. 2. Turn the microscope on using the switch on the bottom right-hand side of the micro-scope stand. On/Off switch is...
Page 28 - Prepare to View a Specimen Slide
Leica DM 500, DM500 B Manual 28 Prepare to View a Specimen Slide 1. Place a specimen slide on the stage by slid- ing the specimen slide forward into the slide grips. Slide grips hold the slide in place. 2. Use the X/Y stage control to position the slide so a portion of the specimen is under the obje...
Page 30 - Viewing Tube Adjustment
Leica DM 500, DM500 B Manual 30 1. Adjust the eyetubes for your interpupillary distance. Fold or unfold the eyetubes to decrease or increase the distance between the eyepieces until you see one illuminated circle. The viewing tubes maintain a constant tube length for all interpupillary settings. T...
Page 36 - Care of the Microscope
Leica DM 500, DM500 B Manual 36 Care of the Microscope
Page 37 - General maintenance
Leica DM 500, DM500 B Manual 37 General • Always carry the microscope using two hands. There is a handle on the back of the microscope and an undercut in the front for this purpose. Ϙ The cord wrap allows you to wrap the cord in such a way that only the length you need is extended. Ϙ Keep all optic...
Page 39 - Dimensions