Page 2 - IMPORTANT SAFETY INFORMATION
Note: This is a professional grade product. A knowledge of construction techniques, plumbing and electricalinstallation according to codes are required for proper installation and user satisfaction. We recommend thata licensed contractor perform the installation of all Jacuzzi Whirlpool Bath © produ...
Page 4 - DIMENSIONS; BASE SPECIFICATIONS; TOTAL WEIGHT/FLOOR LOADING; SPECIFICATIONS; TOP VIEW
Important: Read complete instructions before beginning installation. Each unit arrives ready for installation, equipped with base, glass and associated hardware.Remove the unit from the carton. Retain the shipping carton until satisfactory inspection of the product has been made. Immediately upon re...
Page 5 - ENCLOSURE SPECIFICATIONS
ROUGH-IN REFERENCE ENCLOSURE SPECIFICATIONS 48" 27-11/16" TOP VIEW 72" 38-15/16" 36" 1" TILE FLANGE BLOWER MOTOR FOR UNITS WITH AIR AIR LINE FOR UNITS WITH AIR 84" 72" 48" FRONT VIEW SIDE VIEW 3 Jacuzzi Whirlpool Bath © BY82000 03/05
Page 6 - COMPONENT IDENTIFICATION
COMPONENT IDENTIFICATION FRONT VIEW SIDE VIEW GLASS SIDE PANEL GLASS DOORS RAIL BRACKET AND COVER CAP SIDE SUPPORT RAIL CENTER SUPPORT RAIL AIR TOWER WATER TOWER SEAT BASE DOOR POST DOOR POST WATER TOWER WALL POST GLASS SIDE PANEL (SUPPORT AND SIDE SUPPORT RAILS NOT SHOWN) GLASS SIDE PANEL AIR TOWER...
Page 7 - BASE INSTALLATION; DETAIL 1
PRELIMINARY ROUGH-IN The floor structure beneath the unit must be able to support a total weight of the unit and bather. Refer to page 2, SPECIFICATIONS, for weight specifica-tions . Refer to COMPONENT IDENTIFICATION onpage 4 to help identify parts. STEP 1 Provide an opening in the subfloor no less ...
Page 8 - INCORRECT; CORRECT; SHIM INSTRUCTIONS
STEP 6 With a large screwdriver and the tool included with the drain, tighten the inside compression nut to seal thedrain pipe connection. After drain is fully installed, testfor proper drainage. If the shower base does not drainproperly, rectify this condition before proceeding withthe installation...
Page 9 - DO NOT FILL; See Shim Instructions on page 6.
STEP 7 Place cement board or equivalent on top of shower base flange and secure to studwall. Apply tile (or other finishing material) leaving a 1/8" gap between the finishing material and the shower baseflange lip. Seal this gap with silicone sealant. Leave aminimum 1/4" gap at the back and ...
Page 10 - TOWERS AND DOORS INSTALLATION; WATER TOWER DETAIL
TOWERS AND DOORS INSTALLATION THESE INSTRUCTIONS ARE FOR SUMMER RAINUNITS WITH AND WITHOUT AIR FEATURE OPTION.REFER TO COMPONENT IDENTIFICATION ON PAGE4 TO HELP IDENTIFY PARTS. All wall finish tiling, trim, and sealing should becompleted before beginning this part of the installa-tion. STEP 1 Positi...
Page 11 - DO NOT FORCE CENTER RAIL INTO SLOTS.; With center support rail; DETAIL A
TOWERS AND DOORS INSTALLATION STEP 4 Take the side support rails and install a cover cap and wall bracket on each end. Place the center support rail into sloton each tower. If rail does not readily fit into slots, it may be necessary to loosen the bolts holding towers to base (itmay only be necessar...
Page 12 - Attach air supply pipe to air tower plumbing.
TOWERS AND DOORS INSTALLATION STEP 5 Two shut-off valves are provided per water tower. Tohook up supply lines, unscrew valves from braided line.Using thread sealant, screw each valve to stub out atbottom of tower. Then reconnect braided line usingprovided gasket. Do not twist or kink supply lines wh...
Page 13 - SHOWER BASE
TOWERS AND DOORS INSTALLATION STEP 6 Move the door assembly to the door post on water towerand slide the assembly into the door post. Locate thebase of the door into the slot of serrated door positionerthat positions the hinge barrel as shown. BOTTOM OF DOOR FRAME HINGE BARREL SHOWER BASE WATER TOWE...
Page 14 - Slide fixed glass panel all the way into wall post.
TOWERS AND DOORS INSTALLATION FINISH WALL EDGEOF BASE GLASS SIDEPANEL MOUNTEDPARALLEL TO EDGE OF BASE WALL POST TAPE (3) SCREWS (3) STEP 9 Position the fixed glass wall post so that the glass sidepanel will be parallel with the outside edge of the base.The fixed glass wall post position may vary sli...
Page 15 - TOWER AND DOOR INSTALLATION; NOTE: The glazing is to be installed on the; outside; of
TOWER AND DOOR INSTALLATION STEP 12 Align the glass with glass jamb and insert. RepeatSTEPS 8 through STEP 10 for the other fixed glasspanel. WALL POST GLASS GLAZING GASKET INSIDE OFENCLOSURE APPLY SEALANT JAMB GLASS GLAZING GASKET INSIDE OFENCLOSURE APPLY SEALANT STEP 13 Install glazing gasket on f...
Page 16 - TOWERS AND DOOR INSTALLATION; Install fixed glass cover cap on wall post.
STEP 16 Install handles as shown. Note orientation of handle.Hand tighten knob. Flat screw has a screw driver notch.Do not over tighten either knob or flat screw as crackedglass may result. GLASSDOOR WASHERS LARGEWASHER INTERIOR OFSHOWER DOORHINGE TOWER COVER INSERT THIS SIDE FIRST TOWER COVER TOWER...
Page 17 - acetone, ammonia or other solvents on any tower component.; Consult your Jacuzzi Whirlpool Bath
TOWERS AND DOOR INSTALLATION APPLY SEALANT ALONG BASE ANDSIDE OF WALL POST AND GLASS ANDWALL POST (BOTH SIDES) APPLY SEALANTALONG BASEOF FIXED GLASS(BOTH SIDES) APPLY SEALANT ALONG SIDE OF JAMBAND DOOR POST AND JAMB AND GLASS(BOTH TOWERS) APPLY SEALANT ALL AROUNDTOWER BASES (ALL 3 BASES) (RAIL NOT S...
Page 18 - OPERATION; SHOWER TOWERS; Shower Head; LESS FLOW AND INTENSITY; STOP RELEASE
OPERATION SHOWER TOWERS 16 Jacuzzi Whirlpool Bath © BY82000 03/05 Shower Head There are three selectable positions: Jet, Normal Pul-sating, and Aerated flow. Body Sprays (2 Upper and 2 Lower) To adjust the flow and intensity, turn as shown. Thespray can also be turned to change the direction of thes...
Page 19 - CONTROLLER; AIR TOWER; AIR FLOW LED; AIR TOWER CONTROLS
OPERATION CONTROLLER To turn ON press ON/OFF button or turn ON water at either shower tower.The unit will then automatically go into a preheat cycle to heat the airtransmission pipes. There will be a 5 (five) minute pause while the systempreheats. During this time both LEDs will be ON. When ready fo...
Page 20 - MAINTENANCE
To remove any lime scale from the shower head and body sprays, rub with your finger the outer ring of nozzles on theshower head and all nozzles on the body spray. To clean the foot temperature tester, unscrew the nozzle and back flush the wire mesh filter. Do not use metal tools(such as scissors or ...
Page 21 - TOWER FIXTURES REPAIR PARTS
TOWER FIXTURES REPAIR PARTS 19 Jacuzzi Whirlpool Bath © BY82000 03/05 TOWER ASSEMBLY WASHER (PART OF D709827) 4 6 9 (5X) 10 11 (4X) 13 14 15 16 17 18 19 3 (5X) 2 (5X) 1 (5X) 8 5 12 PART OF D709827 7 (PART OF U547000) 1. C546000 Lock Nut, 1/2" NPT WP (5X) 2. G559000 Ring Compression SS (5X) 3. G5...
Page 22 - TOWER PLUMBING REPAIR PARTS
TOWER PLUMBING REPAIR PARTS 1 11 4 5 4 7 10 6 14 12 13 5 4 16 11 2 8 2 3 2 3 3 17 15 9 18 19 18 18 18 ITEMNO. QTY. PART NO. DESCRIPTION 1 1 Y221000 TOWER, 2 PERSON SHOWER 2 3 U401000 FTG, ELL, .50" FST x 10 mm BARB 3 4 Y724000 1/2" ELBOW, SLIP x THREAD, SCH 40 4 3 7164000 ELL, STREET, .50...
Page 24 - Jacuzzi Whirlpool Bath National Headquarters; PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Printed in U.S.A . Jacuzzi Whirlpool Bath © BY82000 03/05 Printed on Recycled Paper Jacuzzi Whirlpool Bath National Headquarters P.O. Box 702168, Dallas, TX 75370-2168 Service Support: (800) 288-4002 PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. USE INSTALLATION INSTRUCTIONS SUPPLIED ...
Page 25 - WARRANTY COVERAGE; RETURN OF WARRANTY CARD; Jacuzzi Whirlpool Bath Limited Warranty
Jacuzzi Whirlpool Bath P.O. Box 702168Dallas, TX 75370-2168 WARRANTY COVERAGE Jacuzzi Whirlpool Bath (the “Company”) offers the following express limited warranty to the original purchaser of any Jacuzzi Whirlpool Bath Designer Collection Bath Product (“unit”) who purchases the product for personal ...
Page 26 - RESPONSIBILITIES OF OTHERS; WARRANTY SERVICE; Warranty
RESPONSIBILITIES OF OTHERS Inspecting the unit prior to installation is the responsibility of the installer or building contractor who acts on behalf of the user. They are responsible for ensuring the unit is free of defect or damage. Notices are placed on and in the unit and on the shipping carton ...