Page 2 - IMPORTANT SAFETY INFORMATION
Note: This is a professional grade product. A knowledge of construction techniques, plumbing and electricalinstallation according to codes are required for proper installation and user satisfaction. We recommend thata licensed contractor perform the installation of all Jacuzzi Whirlpool Bath product...
Page 3 - Save These Instructions for Future Use.; CONTENTS
Owner's Record Save These Instructions for Future Use. Date Purchased ____________________________________________________________ Purchased From ____________________________________________________________ Installed By ________________________________________________________________ Serial Number _...
Page 4 - following this inspection.; BASE SPECIFICATIONS; WALL SPECIFICATIONS; TOP VIEW
Important: Read complete instructions before beginning installation. Each unit arrives ready for installation, equipped with base, glass and associated hardware. Remove the unit from the carton. Retain the shipping carton until satisfactory inspection of the product has been made. Immediately upon r...
Page 5 - WALL ROUGH-IN REFERENCE; FRONT VIEW
3 2 WALL ROUGH-IN REFERENCE 60" 42-5/16" 33-3/4" 27-15/16" 84" 23" 21-1/2" FRONT VIEW TOP VIEW 1/2" RIGIDCOPPER PIPEUNDER BASE COLD SUPPLY 1-1/2" TILE FLANGE HOT SUPPLY MINIMUM WATER PRESSUREFOR THE SYSTEM IS 40PSI
Page 6 - WALL COMPONENT IDENTIFICATION
2 WALL COMPONENT IDENTIFICATION 4 HEX WRENCH (1)(PROVIDED) STRAIGHT GLASS WALL MOUNTING POST STRAIGHT GLASS PANEL MOUNTINGPOSTCAP (2) 3 SCREWS AND3 WALL ANCHORSPER MOUNTINGPOST CURVED GLASS WALL MOUNTING POST TOWER WITH PLUMBING,FIXTURES, MAGNETICGASKET, BOTTOM PLATEAND TOP COVER(PREASSEMBLED) GLAZI...
Page 7 - The floor structure beneath the unit must be able to; WALL BASE INSTALLATION; INSTALLATION INSTRUCTIONS
5 PRELIMINARY ROUGH-IN SPREAD MORTAR OR LEVELING COMPOUND ETC.EVENLY OVER ENTIRE AREA STRAINER DRAINASSEMBLY SILICONESEALANT SHOWER BASE RUBBER WASHER FIBER WASHER NUT APPLY LUBRICANT The floor structure beneath the unit must be able to support a total weight of the unit and bather. Referto the tabl...
Page 8 - NOTE: Watertight installation of the drain is the; Replace the strainer and tape over the drain hole to; NOTE: If there is any gap between base flange and
6 TIGHTEN SEALING NUT TOOL(INCLUDED) GAP TILEFLANGE INCORRECT SHIM STUD CORRECT TILEFLANGE STUD USESCREWS(PROVIDED) USESCREWS(PROVIDED) STEP 5 With a large screwdriver and the tool included with the drain, tighten the inside compression nut to seal thedrain pipe connection. After drain is fully inst...
Page 9 - CLEAN-UP AFTER INSTALLATION
7 2 WALL BASE INSTALLATION STUD CEMENT BOARD 1/4" MINIMUM GAP SILICONESEALANT TILE TILEADHESIVE 1/4" MINIMUM GAP SILICONESEALANT STUD CEMENTBOARD 1/8" GAP GROUT STUD SHIM IF NECESSARY DO NOT FILL CEMENT BOARD TILE SILICONESEALANT 1-1/8" MAXIMUM NO MINIMUM STEP 7 Apply tile (or other ...
Page 10 - WALL: TOWER, FIXED WALL AND CURVED GLASS INSTALLATION
8 STEP 1Position the wall posts so the edge of the post is set back3/4" (19 mm) in from the edge of the base STEP 2Level both wall posts in their proper position and markwhere screw holes are to be drilled. Drill 3/16" holes andsecure with wall anchors and screws provided. Cut a 12"strip...
Page 15 - WALL SPECIFICATIONS
13 Important: Read complete instructions before beginning installation. Each unit arrives ready for installation, equipped with base, glass and associated hardware. Remove the unit from the carton. Retain the shipping carton until satisfactory inspection of the product has been made. Immediately upo...
Page 16 - WALL ROUGH-IN REFERENCE
3 WALL ROUGH-IN REFERENCE 60" 42-5/16" 33-3/4" 27-15/16" 84" 23" 21-1/2" FRONT VIEW TOP VIEW 1/2" RIGIDCOPPER PIPEUNDER BASE COLD SUPPLY 1-1/2" TILE FLANGE HOT SUPPLY MINIMUM WATER PRESSUREFOR THE SYSTEM IS 40PSI 14
Page 17 - WALL COMPONENT IDENTIFICATION
3 WALL COMPONENT IDENTIFICATION HEX WRENCH (1)(PROVIDED) MOUNTINGPOSTCAP 3 SCREWS AND3 WALL ANCHORS CURVED GLASS WALL MOUNTING POST TOWER WITH PLUMBING,FIXTURES, MAGNETICGASKET, BOTTOM PLATEAND TOP COVER(PREASSEMBLED) TOWER MOUNTINGBOLT & WASHER CURVED GLASS GLAZING GASKET (2) FRONTRAIL BRACKETC...
Page 18 - WALL BASE INSTALLATION
3 WALL BASE INSTALLATION The floor structure beneath the unit must be able to support a total weight of the unit and bather. Referto the table under total weight.STEP 1 Provide an opening in the subfloor no less than 5" x 5" square. This opening should be located on the centerlines of the sh...
Page 19 - With a large screwdriver and the tool included with the; INCORRECT; CORRECT
3 WALL BASE INSTALLATION STEP 5 With a large screwdriver and the tool included with the drain, tighten the inside compression nut to seal thedrain pipe connection. After drain is fully installed, testfor proper drainage. If the shower base does not drainproperly, rectify this condition before procee...
Page 21 - WALL: TOWER AND CURVED GLASS INSTALLATION
3 WALL: TOWER AND CURVED GLASS INSTALLATION STEP 1Position the wall post so the edge of the post is set back3/4" (19 mm) in from the finish wall. STEP 2Level the post in its proper position and mark wherescrew holes are to be drilled. Drill 3/16" holes and securewith wall anchors and screws ...
Page 25 - Foot Temperature Testor
2 & 3 WALL OPERATION 23 STOP RELEASE Temperature ValveThe temperature of the mixed water is adjusted by means of thegraduated handle. This handle has a safety stop set at 100 ° F (38 ° C). To increase the temperature, press the red button to release the stop and keep turning the handle. Shower H...
Page 26 - & 3 WALL MAINTENANCE; Jacuzzi Whirlpool Bath; Authorized Service
24 2 & 3 WALL MAINTENANCE To remove any lime scale from the shower head and body sprays , rub with your finger the outer ring of nozzles onthe shower head and all nozzles on the body spray. To clean the foot temperature tester, unscrew the nozzle and back flush the wire mesh filter. Do not use m...
Page 27 - TOWER FIXTURES REPAIR PARTS
TOWER FIXTURES REPAIR PARTS 1. C546000 Lock Nut, 1/2" NPT WP (5X)2. G559000 Ring Compression SS (5X)3. G560000 Washer Rubber (5X)4. U546000 (Part of U547000) Nut Transfer Valve, Chrome5. U566000 Gasket, 1.41 ID X .063 Thick6. U547000 Valve, Mixer/Transfer Assembly7. U550827 (Part of U547000) 567...
Page 28 - TOWER PLUMBING REPAIR PARTS
TOWER PLUMBING REPAIR PARTS 1. A944000 (9X) Spring Clamp, .625 OD Hose2. U405000 L=31.0" Tubing, PVC Reinforced, 10mm Barb3. U405000 L=5.5" Tubing, PVC Reinforced, 10mm Barb4. A945000 (7X) Spring Clip, .75 OD Hose5. U400000 FTG, Straight, 1/2" FTS X 10mm Barb6. U403000 (2X) Cap, 1/2"...
Page 29 - WALL UNIT REPAIR PARTS
1 2 3 4 5 (2X) 6 (2X) 7 (6X) 8 9 10 11 12 13 (6X) 15 17 16 18 20 21 14 (6X) 1. U134827 Rail Back Walk-in2. U133827 Rail 2 Wall Walk-in3. U245827 Rail Assembly Walk-in4. U149000 Bracket, Mounting Rail5. U119827 Wall Post, Panel6. U138827 Cap, Wall Post7. J686000 Tape High Bond, 2 Sided8. U159000 Gask...
Page 30 - WALL UNIT REPAIR PARTS
3 WALL UNIT REPAIR PARTS 1. U134827 Rail Back Walk-in 3 Wall2. U245827 Rail Assembly Walk-in 3 Wall3. U149000 Bracket, Mounting Rail4. U119827 Wall Post, Panel5. U138827 Cap, Wall Post6. U124XXX Tower Cover7. U257XXX Final Shell, Tower, Walk-in 3-Wall U126XXX Tower Body Walk-in U136XXX Cap, Top Towe...
Page 31 - Jacuzzi Whirlpool Bath Limited Warranty
Jacuzzi Whirlpool Bath P.O. Box 702168 Dallas, TX 75370-2168 WARRANTY COVERAGE Jacuzzi Whirlpool Bath (the “Company”) offers the following express limited warranty to the original purchaser of any Jacuzzi Whirlpool Bath Designer Collection Bath Product (“unit”) who purchases the product for personal...
Page 32 - Warranty
RESPONSIBILITIES OF OTHERS Inspecting the unit prior to installation is the responsibility of the installer or building contractor who acts on behalf of the user. They are responsible for ensuring the unit is free of defect or damage. Notices are placed on and in the unit and on the shipping carton ...