Page 2 - Installation; CAUTION; Fig. 2—Mounting wallplate or subbase to wall.

69-0564—3 2 Installation WHEN INSTALLING THIS PRODUCT… 1. Read these instructions carefully. Failure to follow them could cause a hazardous condition. 2. Installer must be a trained experienced service technician.3. After installation is complete, check out product op- eration as provided in these i...

Page 3 - WIRE WALLPLATE OR SUBBASE; Fig. 4—Mounting wallplate or subbase on horizontal outlet box.

3 69-0564—3 Fig. 3—Leveling methods for wallplate orsubbase. AUTO OFF COOL HEAT ON FAN B O W Y R G M1555 SPIRIT LEVEL PLUMBLINE PLUMBBOB ORWEIGHT Outlet Box Mounting (Fig. 4) Use a horizontally mounted outlet box if possible. If a vertical outlet box is used, mount the wallplate or subbase ona 20268...

Page 4 - Subbase; Control transformer power.; MOUNT THE THERMOSTAT; not reverse the knob.; ATTACH THERMOSTAT COVER

69-0564—3 4 Fig. 5—Methods of connecting terminals. BARRIER FOR WRAPAROUNDCONNECTION—STRIP 7/16 in. [11 mm] FOR STRAIGHTCONNECTION—STRIP 5/16 in. [8 mm] M1556B TABLE 2—TERMINAL DESIGNATIONS. Subbase Terminal Control Function R Control transformer power. W Heating control circuit. Y Cooling control c...

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8

Summary

Page 2 - Installation; CAUTION; Fig. 2—Mounting wallplate or subbase to wall.

69-0564—3 2 Installation WHEN INSTALLING THIS PRODUCT… 1. Read these instructions carefully. Failure to follow them could cause a hazardous condition. 2. Installer must be a trained experienced service technician.3. After installation is complete, check out product op- eration as provided in these i...

Page 3 - WIRE WALLPLATE OR SUBBASE; Fig. 4—Mounting wallplate or subbase on horizontal outlet box.

3 69-0564—3 Fig. 3—Leveling methods for wallplate orsubbase. AUTO OFF COOL HEAT ON FAN B O W Y R G M1555 SPIRIT LEVEL PLUMBLINE PLUMBBOB ORWEIGHT Outlet Box Mounting (Fig. 4) Use a horizontally mounted outlet box if possible. If a vertical outlet box is used, mount the wallplate or subbase ona 20268...

Page 4 - Subbase; Control transformer power.; MOUNT THE THERMOSTAT; not reverse the knob.; ATTACH THERMOSTAT COVER

69-0564—3 4 Fig. 5—Methods of connecting terminals. BARRIER FOR WRAPAROUNDCONNECTION—STRIP 7/16 in. [11 mm] FOR STRAIGHTCONNECTION—STRIP 5/16 in. [8 mm] M1556B TABLE 2—TERMINAL DESIGNATIONS. Subbase Terminal Control Function R Control transformer power. W Heating control circuit. Y Cooling control c...