LYNX Touch Installation and Setup Guide - 2 - RECOMMENDATIONS FOR PROPER PROTECTION The Following Recommendations for the Location of Fire and Burglary Detection Devices Help Provide Proper Coverage for the Protected Premises. Recommendations for Smoke and Heat Detectors With regard to the number an...
LYNX Touch Installation and Setup Guide -3- Table of Contents System Features ..................................................................................................................................................................................... 5 Installing the Control ..................
LYNX Touch Installation and Setup Guide - 5 - System Features The LYNX Touch L5200 and L7000 series controls are self-contained, rechargeable wireless control/communicator that features easy installation and usage. A built-in speaker provides voice annunciation of system status along with voice desc...
LYNX Touch Installation and Setup Guide - 6 - System Features Communication L5200 L7000 ADEMCO Contact ID SIA (DC-03) Internet central station communication GSM cellular central station communication WiFi Central station communication Two-way voice communication ...
LYNX Touch Installation and Setup Guide - 7 - Installing the Control Wall Mounting For wall mounting follow the steps below and refer to the appropriate figure for the LYNX Touch L5200 OR L7000 control. 1. Release the front case assembly from the back case by depressing the two locking tabs at the t...
LYNX Touch Installation and Setup Guide - 9 - Wiring Connections 5000-100-094-V4 Make Earth Ground Connection - The de s ign a ted e a rth gro u nd termin a l EGND m us t b e termin a ted in a good e a rth gro u nd for the lightning tr a n s ient protective device s in thi s prod u ct to b e effecti...
LYNX Touch Installation and Setup Guide - 10 - AC Power and Backup Battery General The system is powered by a 9 Volt DC, 2.7 Amp Plug-in Power Supply, 300-04705/300-04705V1, or 300- 04065/300-04065V1 (300-04063/300-04063V1 or 300-04064/300-04064V1 in Canada). Refer to the wiring table below for wire...
LYNX Touch Installation and Setup Guide - 11 - AC Power and Backup Battery 5000-100-09 3 -V2 OR RETAINER S CREW RETAINER S CREW BATTERY CABLE CHANNEL BATTERY PACK(P/N 3 00-0 38 66/ LYNXRCHKIT- S HA) BATTERY PACK (P/N 3 00-0 38 64-1/ LYNXRCHKIT- S C) BATTERY WIRE ROUTING CLIP S ( 3 ) L5200 Battery In...
LYNX Touch Installation and Setup Guide - 12 - Installing/Configuring Communication & Home Automation Modules General This LYNX Touch controls support Central Station reporting using wireless/cellular (GSM) WiFi and hardwire (IP) communications modules. They also support upload/download programm...
LYNX Touch Installation and Setup Guide - 13 - Installing/Configuring Communication & Home Automation Modules S CREW ( 3 ) S IM CARD 5000-100-151-V 3 ROTATED 1 8 0 CONNECTOR BOARD CONNECTOR BOARD RECEPTACLE 4GL/4GLC OR G S MVLP5-4G/G S MVLP5CN4G LYNX TOUCH L5200 LOCKING TAB S L5200 GSM Communica...
LYNX Touch Installation and Setup Guide - 14 - Installing/Configuring Communication & Home Automation Modules Installing the ILP5 Ethernet Communications Module Do not install the ILP5 if the L5100-WiFi communications module is being installed. Ensure that the connector board and cable are secur...
LYNX Touch Installation and Setup Guide - 15 - Installing/Configuring Communication & Home Automation Modules 7000-100-014-V1 REMOVE ILP5 S PACER REMOVE ILP5 KNOCKOUT S CREW ( 3 ) ROTATED 1 8 0 CONNECTOR BOARD CONNECTOR BOARD RECEPTACLE ILP5 LYNX TOUCH L7000 TIE WRAPPOINT ILP5 S PACER TIE WRAP (...
LYNX Touch Installation and Setup Guide - 17 - Installing Wireless Zones General Information Zones The L5200 and L7000 controls respectively support up to 79 and 103 total wireless zones using 5800 Series transmitters, and wireless buttons. Range The built-in RF receiver can detect signals from wire...
LYNX Touch Installation and Setup Guide - 18 - Installing Wireless Zones RF Sniffer Test Mode This mode is used after all transmitters have been entered to check that all transmitters have been properly programmed. Sniffer mode does not automatically expire. You must manually exit Sniffer mode by se...
LYNX Touch Installation and Setup Guide - 19 - Installing Wireless Zones 5800 Series Transmitter Loop Numbers (Refer to this information when programming transmitters) The following illustration shows the compatible transmitters, their associated input types and loop designations. LOOP 1 5806/5806W3...
LYNX Touch Installation and Setup Guide - 20 - Mechanics of Programming Navigating Menus Touch-screen Display LYNX Touch’s Liquid Crystal Display (LCD) touch-screen displays variable icons and text on “screens”. The screen displays status icons and associated text, the current time and date, system ...
LYNX Touch Installation and Setup Guide - 21 - Mechanics of Programming Navigation Keys Navigating through the screens is accomplished by lightly touching the icons or menu items on the touch-screen. Once activated, the control advances to the next screen. Selecting the “Home” (cancel) key or the “ ...
LYNX Touch Installation and Setup Guide - 22 - Mechanics of Programming Navigating Menus Security Screen System Status is displayed at the top of each screen and the time and date are displayed at the bottom of the Security Screen. The Security menu Screens differ between the LYNX Touch L5200 and th...
LYNX Touch Installation and Setup Guide - 23 - Mechanics of Programming General Programming Information When power cycling the control, remove AC power first and wait approximately 1 minute before disconnecting battery. Programming options are stored in non-removable, electrically erasable, nonvolat...
LYNX Touch Installation and Setup Guide - 24 - Mechanics of Programming Loading Factory Defaults To load the factory defaults, enter the Installer Programming Mode and advance to second page of the System Programming and refer to following procedure. Refer to the Programming Default Values section o...
LYNX Touch Installation and Setup Guide - 25 - Zone Response Type Definitions General Information During programming, you must assign a zone type to each zone, which defines the way in which the system responds to faults in that zone. Zone types are defined below. Type Function Characteristics Not U...
LYNX Touch Installation and Setup Guide - 27 - Programming the Control After entering the System Programming mode select from the options provided on the First and Second Installer Programming tools screens as shown in the accompanying figure. System Programming... 5000-100-013- V 1 System Type Inst...
LYNX Touch Installation and Setup Guide - 28 - Programming the Control System Type The following system options are programmed in this section: Option Function RF Jam Enable or disable RF Jam Log and Reporting Speaker Phone Enable or disable Speaker Phone mode. (Only available on the LYNX Touch L520...
LYNX Touch Installation and Setup Guide - 30 - Programming the Control Program Date and Time Note: If applicable, preprogrammed defaults for the L5200/L7000 Control are shown on the screen unless otherwise noted. SCREEN ACTION 5000-100-131-V0 Date Time Note: If you are installing a 4GL/4GLC or GSMVL...
LYNX Touch Installation and Setup Guide - 31 - Programming the Control Program the Communications Module A router is required if you are installing the L5100-WiFi module. The router must be powered on and connected for WiFi operation (alarm reporting) to occur. The following system options are progr...
LYNX Touch Installation and Setup Guide - 32 - Programming the Control Program the Communications Module (Continued) SCREEN ACTION City ID 4. Select “City ID”. Enter the 2-digit Primary City ID (Decimal). Options 01-99 CS ID 5. Select “CS ID”. Enter the 2-digit Primary Central Station ID (HEX). Opti...
LYNX Touch Installation and Setup Guide - 33 - Programming the Control Program the Communications Module (Continued) GSM Fault Time (min) 00 19. Select “GSM Fault Time (min)”. Enter the time delay (in minutes) on the keypad. Options 00-99 GSM Rollover No 20. If “WiFi and GSM” was selected in step 2,...
LYNX Touch Installation and Setup Guide - 34 - Programming the Control Program the Z-Wave Module The following system options are programmed in this section: Option Function Z-Wave Enables or disables the Z-Wave Module Temperature Display Toggles between Fahrenheit and Celsius (for Z-Wave compatible...
LYNX Touch Installation and Setup Guide - 35 - Programming the Control Program Zones The following system options are programmed in this section: Option Function Serial Number Manually enter device serial number or enroll via RF transmission Loop Number Manually enter device loop number or enroll vi...
LYNX Touch Installation and Setup Guide - 37 - Programming the Control Program Zones (Continued) Supervision Supervised Supervision The system displays the applicable Supervision options based upon the Device Type that was selected. Select “Supervision” to scroll between the following options: Hardw...
LYNX Touch Installation and Setup Guide - 38 - Programming the Control Program Keys The following system options are programmed in this section Option Function Key Type Select the specific type of key being entered or enrolled User Associates the Key with a specific User Serial Number Manually enter...
LYNX Touch Installation and Setup Guide - 40 - Programming the Control Program Reporting When Compass service is required and GSM or IP are the only reporting channels: As part of Primary Central Station programming; the “Phone Type” must be set to any selection other than “None”, the “Communicator ...
LYNX Touch Installation and Setup Guide - 41 - Programming the Control Program Reporting (Continued) Notes: If applicable, preprogrammed defaults for the L5200/L7000 Control are shown on the screen unless otherwise noted. When GSM is used as the Primary Communications channel for any Total Connect s...
LYNX Touch Installation and Setup Guide - 45 - Programming the Control Program Reporting (Continued) SCREEN ACTION Options Select “Options”. The System displays the following options: PBX Call Wait Cancel Number of Reports Alarm Report Delay First Report Offset Report Frequency PBX Note: This field ...
LYNX Touch Installation and Setup Guide - 46 - Programming the Control Program Reporting (Continued) Ring Counter 2 This option only appears if Answering Machine defeat is set to “No”. Enter ring counter (1 – 14 rings) on the displayed keypad. Flexible Callback No Select “Flexible Callback”, the sys...
LYNX Touch Installation and Setup Guide - 47 - Programming the Control Program Sounder The following system options are programmed in this section: Option Function Burglary Alarm Sound Switches the full 110 dB alarm sound for burglary On/Off. Burglary Bell Timeout Select the time for timeout of the ...
LYNX Touch Installation and Setup Guide - 48 - Programming the Control Program System Settings The following system options are programmed in this section: Option Function Entry Delay1/Entry Delay 2 Selects an Entry Delay time in seconds. The system will wait the time entered before sounding alarm u...
LYNX Touch Installation and Setup Guide - 49 - Programming the Control Program System Settings Note: If applicable, preprogrammed defaults for the L5200/L7000 Control are shown on the screen unless otherwise noted. SCREEN ACTION System Settings Select “System Settings” The System displays the follow...
LYNX Touch Installation and Setup Guide - 50 - Programming the Control Program System Settings (Continued) SCREEN ACTION Backlight Timeout No Select “Backlight Timeout”. The System toggles between No and 30 Seconds. Quick Arm Yes Select “Quick Arm”. The System toggles between Yes and No. Quick Exit ...
LYNX Touch Installation and Setup Guide - 51 - Programming the Control Communications Diagnostics Communications Status – The system provides a status of the IP or GSM communications paths and performs a self-test of the AES encryption algorithm as follows: Message Meaning GSM: OK Normal; No fault. ...
LYNX Touch Installation and Setup Guide - 52 - Programming the Control Communications ID Numbers – Displays programmed SIM card information Message Meaning MAC: xxxxxxxxxxxx MAC Address indicates the unique identification number for installed communications module(s) MAC CRC: xxxx MAC CRC number for...
LYNX Touch Installation and Setup Guide - 53 - Programming the Control Register through AlarmNet Direct Website If you have programmed the communications module through AlarmNet Direct, you must then transfer the data to the module, and register the module. To do this, please go to: https://services...
LYNX Touch Installation and Setup Guide - 54 - Programming the Control During the registration process the following messages may be displayed: Message Meaning Getting Configuration File… The configuration file is obtained from AlarmNet if the module was programmed through AlarmNet Direct or a previ...
LYNX Touch Installation and Setup Guide - 55 - Programming the Control Update Server This procedure is used to upload the Configuration File to the Server. SCREEN ACTION Comm. Diagnostics 1. Select “Comm. Diagnostics” The System displays the following options depending upon the communication device ...
LYNX Touch Installation and Setup Guide - 56 - Programming the Control SCREEN ACTION WiFi Location None 2. Select “WiFi Location”. The System will scroll between “None” and “Speaker Side”. After selecting “Speaker Side”, the “Configure WiFi” option will be displayed. 3. Select “Configure WiFi”. The ...
LYNX Touch Installation and Setup Guide - 57 - Programming the Control 5. Select “DHCP”. The system scrolls between “Yes” and “No”. If “No” is selected the “Static” button is displayed. Note: When entering a password, up to 31 characters can be entered. The system will only display the first 22 char...
LYNX Touch Installation and Setup Guide - 58 - Remote Programming/Control (Downloading) General Information The control panel can be remotely programmed from an IBM-compatible Personal Computer (PC), Compass Downloader, a HAYES compatible Modem (L5200/L5200CN only) or via a capable GSM or IP Communi...
LYNX Touch Installation and Setup Guide - 59 - Remote Programming/Control (Downloading) Remote Programming Advisory Notes A copy of the program downloaded may be printed using the IBM PC-compatible computer’s internal report generator, when an optional printer is connected (consult your PC manual ...
LYNX Touch Installation and Setup Guide - 60 - System Operation Key/Touchscreen Operation The keys and touchscreen allows the user to arm and disarm the system, and perform other system functions, such as bypassing zones. Zone and system conditions (ALARM, trouble, bypass) are displayed on the displ...
LYNX Touch Installation and Setup Guide - 61 - System Operation Secondary User Codes In normal operation mode, the Master Security Code can be used to assign up to 30 (L5200/L5200CN) or 46 (L7000/L7000CN) secondary 4-digit security codes, including a Guest Code and a Duress Code. The Master Code can...
LYNX Touch Installation and Setup Guide - 62 - System Operation “Follow Me” System Announcement Feature (L5200/L5200CN Only) This feature allows the LYNX Touch to deliver a voice system message to the Follow Me Phone numbers programmed by the installer. The LYNX Touch will first transmit reports to ...
LYNX Touch Installation and Setup Guide - 63 - System Operation “Follow Me” Reminder Feature (L5200/L5200CN Only) The “Follow Me” feature allows the user to schedule a time driven message. When activated, the system will dial the Phone 1 and/or the Phone 2 telephone numbers, which are programmed as ...
LYNX Touch Installation and Setup Guide - 64 - System Operation System Displays The following icons will be displayed on the Home screen along with specific zone status information (if applicable) to indicate system status. DISPLAY DEFINITION DISPLAY DEFINITION DISPLAY DEFINITION AC Loss Door Open F...
LYNX Touch Installation and Setup Guide - 65 - System Operation UL Audio alarm verification has not been evaluated by UL. Audio Alarm Verification (Two-Way Voice Feature) This feature allows the central station operator to listen, talk to or conduct a two-way conversation with an individual(s) at th...
LYNX Touch Installation and Setup Guide - 66 - System Operation Event Log The LYNX Touch Series event log is capable of recording and displaying up to 128 (L5200/L5200CN) or 256 (L7000/L7000CN) system events. The type of events that can be recorded is selectable and is programmed in the System Type ...
LYNX Touch Installation and Setup Guide - 67 - System Operation Central Station Messages The following messages are sent by the L5100 communications modules (4GL/4GLC or GSMVLP5-4G/GSMVLP5CN4G, ILP5 and L5100-WiFi) for the conditions listed below. Alarm Condition Alarm Code Restore Code Power On / R...
LYNX Touch Installation and Setup Guide - 68 - Testing the System TO THE INSTALLER Regular maintenance and inspection (at least annually) by the installer and frequent testing by the user are vital to continuous satisfactory operation of any alarm system. The installer should assume the responsibili...
LYNX Touch Installation and Setup Guide - 69 - Testing the System Dialer Test Note: This test is not available for the LYNX Touch L7000/L7000CN. The Dialer Test checks that the phone connection to the central station is working properly. Notify the Central Station in advance that tests will be in pr...
LYNX Touch Installation and Setup Guide - 73 - LYNX Touch (L5200CN/L7000CN) Canada Programming Default Values Program Function Configuration 1 Configuration 2 Configuration 3 Configuration 4 Installer Code 4112 4112 4112 4112 System Type RF Jam Disabled Disabled Disabled Disabled Speaker Phone (L520...
LYNX Touch Installation and Setup Guide - 76 - Zone Programming Default Values Zone Programming Notes 1. Zone 1 is a hardwire zone; Zones 95, 96 and 99 are keypad panics. 2. For the LYNX Touch L5200/L5200CN Zones 2 to 64 are RF zones (Zones 46 to 48 are reserved for Garage Door Zones); Zones 140-155...
LYNX Touch Installation and Setup Guide - 77 - Zone Programming Default Values Zone Assignment/Alarm Response Types for Values 3 and 4 Zone Number Loop Number Device Type Response Type Alarm Report Chime Supervision Arm Night Zone Descriptor 1 --- New Not Used Yes Disabled End of Line n/a n/a 2 2 Do...
LYNX Touch Installation and Setup Guide - 78 - Regulatory Agency Statements Federal Communications Commission (FCC) Part 15 The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications...
LYNX Touch Installation and Setup Guide - 79 - WARNING THE LIMITATIONS OF THIS ALARM SYSTEM While this System is an advanced design security system, it does not offer guaranteed protection against burglary, fire or other emergency. Any alarm system, whether commercial or residential, is subject to c...
LYNX Touch Installation and Setup Guide - 80 - UL Notices 1. For UL Residential Burglar Alarm installations with line security, total exit delay time must not exceed 60 seconds. For UL Burglar Alarm installations without line security, total exit delay time must not exceed 120 seconds. 2. Periodic t...
LYNX Touch Installation and Setup Guide - 81 - SIA Quick Reference Guide Programming Section Feature Range Shipping Default SIA Requirement Installation and Setup Guide or Programming Guide Reporter / Report Selection Exit Error Enabled or Disabled Enabled Enabled Recent Closing Enabled or Disabled ...
LYNX Touch Installation and Setup Guide - 82 - Specifications LYNX Touch Series Security Controls Physical: Dimensions: 8.5” W x 6” H x 1.875” D Electrical: Voltage Input: 9 Vdc from plug-in 2.7A power supply Rechargeable Backup Battery: Nickel-metal hydride battery pack rated at 7.2 Vdc Communicati...
LYNX Touch Installation and Setup Guide - 83 - Contacting Technical Support PLEASE, before you call Technical Support, be sure you: • READ THE INSTRUCTIONS! • Check all wiring connections. • Determine that the power supply and/or backup battery are supplying proper voltages. • Verify your programmin...
LYNX Touch Installation and Setup Guide - 84 - Glossary AES – Advanced Encryption Standard APL – Advanced Protection Logic dBM – decibals milliwatt (power ratio) DHCP – Dynamic Host Configuration Protocol, which provides a mechanism for allocating IP addresses dynamically so that addresses can be re...
LYNX Touch Installation and Setup Guide - 85 - – Index – 24-hour silent ................................................................. 60 300-03866 ......................................................................... 5 300-04063/300-04063V1 ................................................ 10...
LYNX Touch Installation and Setup Guide - 87 - 5200-100-SOC-V0 2K OHM EOLR PO WER SUPPL Y CONNECT OR HARD WIRED ZONE WEEKL Y TE S TING I S REQ UIRED T O EN S URE PR OPER OPERA TION OF THI S S Y S TEM PREMISES TELEPHONE INCOMING PHONE LINE H/S T H/S R RING TIP EGND EARTH GR OUND HWZ1 TRIG GND GND +9V...
WARRANTY INFORMATION For the latest warranty information, please visit: www.honeywell.com/security/hsc/resources/wa 2013 Ê800-160820Š 800-16082 12/13 Rev. A
Honeywell Manuals
-
Honeywell DT8050A
Installation Manual
-
Honeywell DT8050A
Manual
-
Honeywell DT8050A
User Manual
-
Honeywell DT8050
Manual
-
Honeywell DT8050
User Manual
-
Honeywell TPFIT25WK
User Manual
-
Honeywell TPFIT25AWK
User Manual
-
Honeywell TPFIT32WK
User Manual
-
Honeywell TPFIT32AWK
User Manual
-
Honeywell 24DX47
User Manual
-
Honeywell 24DX47
Manual
-
Honeywell TPFIT50PWK
User Manual
-
Honeywell TPFIT50WK
User Manual
-
Honeywell TPFIT50AWK
User Manual
-
Honeywell TPFIT50APWK
User Manual
-
Honeywell 00010
User Manual
-
Honeywell ADVBLEWIFI
Manual
-
Honeywell ADVBLEWIFI
User Manual
-
Honeywell ADVBLE
Manual
-
Honeywell ADVBLE
User Manual