9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 6/99 ii Copyright, Notices, and Trademarks Printed in U.S.A. – © Copyright 1999 by Honeywell Inc. Revision 3 – 6/99 W hile this information is presented in good faith and believed to be accurate, Honeywelldisclaims the impl...
6/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual iii About This Document Abstract This manual contains instructions for installation and operation of the 9782 SeriesConductivity/Resistivity Analyzer/Controller. Revision Notes The following list provides notes concern...
9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 6/99 iv Contents 1. INTRODUCTION ..................................................................................................... 1-1 1.1 Description .......................................................................
6/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual vii 5.9 Selecting a Computed Value to Be Displayed ............................................................................. 5-21 Purpose ...............................................................................
9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 6/99 viii 8. CALIBRATION ........................................................................................................ 8-1 8.1 Overview ...............................................................................
6/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual ix 10. MAINTENANCE................................................................................................... 10-1 10.1 Overview ....................................................................................
6/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual xi Tables Table 1-1 Key Functions .......................................................................................................................... 1-6Table 1-2 9782 Conductivity/Resistivity Analyzer/Controlle...
9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 6/99 xii Table 10-8 Procedure for Replacing the Fuse ...................................................................................... 10-16 Table 11-1 Part Numbers ........................................................
6/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual xiii Figures Figure 1-1 9782 Front Panel..................................................................................................................... 1-5Figure 1-2 Representative Process Value Display for a Cel...
9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 6/99 xiv
Introduction 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 1-1 1. Introduction 1.1 Description Multi-function instrument The Honeywell 9782 Conductivity/Resistivity Analyzer/Controller (Figure 1-1) is amicroprocessor-based instrument for analysis of conductivity, ...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 1-2 Input Input to the 9782 can be from any Honeywell conductivity cell at distances up to 1500 feet. Outputs Optional isolated 0 to 1 V, 0 to 10 V and 4 to 20 mA outputs ar...
Introduction 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 1-3 1.2 Features Automatic cell washing The standard AutoClean feature can periodically rinse cells automatically. The schedule andduration of the operation are configurable. An internal relay actuates ext...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 1-4 Watertight corrosion-resistant case The 9782 is enclosed in a watertight and corrosion resistant industrial case, designed for panel,pipe or wall mounting. It has an EMI...
Introduction 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 1-7 Selecting a parameter for edit To select a parameter for edit: • display the screen containing the parameter • use the UP or DOWN keys to highlight the parameter name • press the ENTER key to highlight...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 1-8 1.3.2 Online Displays Introduction The online displays available when the operator presses the DISPLAY key depend on thenumber of cells connected to the Analyzer/Control...
Introduction 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 1-9 Combined display If two cells are connected to the Analyzer/Controller, then a display is available that includes themeasured variable for both cells (see Figure 1-3). Another combined display also inc...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 1-10 Clock and AutoClean If the 24-hour clock is turned on, a time display will be available. If AutoClean is configured,then the AutoClean screen will be included in the di...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 1-12 Table 1-2 9782 Conductivity/Resistivity Analyzer/Controller Menu Hierarchy Menu Item Purpose Where Described MAINTENANCE do occasional system tasks Sections 9 and 10 OF...
Introduction 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 1-13 1.5 Planning 1.5.1 Overview Configuration system minimizes decisions The 9782C Analyzer/Controller was designed for easy configuration using menu displays and thekeys on the front panel. Numeric value...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 1-14 Interactions affecting permitted relay assignments Table 1-3 is provided so that you can optimize your use of relays to implement your controlstrategy. Each row in the ...
Introduction 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 1-15 Table 1-3 Available Combinations of Relay Assigments Features Used Relay 1 Relay 2 Relay 3 Relay 4 Alarm 1 Alarm 2 Alarm 3 Alarm 4 Alarm 1 and Diagnostic Alarm 2 Alarm 3 Alarm 4 Alarms Only Alarm 1 Al...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 1-16 1.5.3 Deciding on a Control Strategy All 9782 models can use relays for control All 9782 models have at least two relays. (Two more relays are optional.) Unless dedicat...
Introduction 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 1-17 1.6 Overview of Installation and Setup Tasks Setup tasks described in this manual This manual contains instructions for all installation and operation tasks relating to theAnalyzer/Controller. (Instru...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 1-18 The manual also contains: • information about diagnostics, status messages, and system error messages(Section 9) • instructions for returning all parameter values to th...
Specifications and Model Number 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 2-1 2. Specifications and Model Number 2.1 Specifications 2.1.1 User Interface Display LCD dot matrix display, 128 by 64 dpi. Backlit: solid state LED. Displays Cell 1 and Cell 2values i...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 2-2 CE conformity This product is in conformance with the protection requirements of the following EuropeanCouncil Directives: 89/336/EEC, the Electromagnetic Compatibility ...
Specifications and Model Number 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 2-3 Wide range models Wide Display Ranges: 9782C-W0 Conductivity (microsiemens/cm) TDS Cell Constant Required (cm-1) 100-1,999 0-1,999 ppm 0.1 1000-19,990 0-19,990 ppm 1 Conductivity (mi...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 2-4 Performance under reference operating conditions Display Accuracy: Standard Ranges (Conductivity/Resistivity); ±0.5% of reading. Wide Ranges (Conductivity); ±0.5% of rea...
Specifications and Model Number 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 2-5 2.1.8 Temperature Compensation Availability All models can provide high resolution (0.05º C, typical) temperature compensation bymicroprocessor calculation over 0 to 140º C for high ...
Specifications and Model Number 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 2-7 2.2 Model Number Breakdown Introduction The model number breakdown is presented in the tables that follow. The basic model number consists of a key number. Appended to this key numbe...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 2-8 TABLE I - INPUTSpH/ORP ElectrodespH from External Pre-amp 01 Direct Glass/Antimony pH/ORP Electrode/Internal Pre-amp 02 Direct DURAFET pH electrode, Internal Pre-amp 03 ...
Unpacking, Preparation, and Mounting 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 3-1 3. Unpacking, Preparation, and Mounting 3.1 Overview Introduction This section contains instructions for unpacking, preparing, and mounting theAnalyzer/Controller. Instructions ...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 3-2 3.2 Unpacking and Preparing Procedure Table 3-1 contains procedure for unpacking and preparing the 9782. Table 3-1 Procedure for Unpacking and Preparing the 9782 Step Ac...
Unpacking, Preparation, and Mounting 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 3-3 Honeywell York, PA U.S.A. ATTENTION - UNIT SET FOR 240 VAC 9782C-S0-VC-E0010-00S/N: 9751Y712345670001USA WARRANTY ASSISTANCE - 1 - 800-423-9883 120/240 VAC 50/60 Hz 15VAContact ...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 3-4 Figure 3-2-1 Mounting and Dimensions – Non-Backlit Display Option 7.68 ± .060 195.07 ± 1.52 3.06 77.80 7.43 ± .070 188.72 ± 1.78 1.0025.40 IPS Pipe(by customer) Note 1: ...
Unpacking, Preparation, and Mounting 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 3-5 Figure 3-2-2 Mounting and Dimensions – Non-Backlit Display Option 6.43 ±0.70 163.32 ±1.78 C L 1.00 ±.025 25.40 ±0.64 6.27 ±.040 159.26 ±1.02 .12 min. 3.04 .37 max. 9.40 3.31 84....
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 3-6 7.68 ± .060 195.07 ± 1.52 3.06 77.80 7.64 ± .070 194.06 ± 1.78 1.0025.40 IPS Pipe(by customer) Note 1: Do not exceed 80 lb-in torque when tightening fastners. Horizontal...
Unpacking, Preparation, and Mounting 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 3-7 Figure 3-3-2 Mounting and Dimensions – Backlit Display Option 6.43 ±0.70 163.32 ±1.78 C L 1.21 ±.025 30.73 ±0.64 6.27 ±.040 159.26 ±1.02 .12 min. 3.04 .37 max. 9.40 3.31 84.07 6...
Power Wiring 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 4-1 4. Power Wiring 4.1 Overview Introduction This section contains instructions for installing ac power wiring for the Analyzer/Controller, inpreparation for configuring the software and performing I/O se...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 4-2 4.2 General Wiring Practices for Power Wiring WARNING W iring should be performed by qualified personnel only. Safety precautions WARNING A disconnect switch must be ins...
Power Wiring 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 4-3 4.3 Power Wiring Considerations Recommended wire size Observe all national and local electrical codes when making power connections. Unless locallyapplicable codes dictate otherwise, use 14 gauge (2.08...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 4-4 4.4 Installing Power Wiring Procedure Follow the procedure in Table 4-1 to install AC power wiring. WARNING Turn power off at mains before installing AC power wiring. Ta...
Power Wiring 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 4-5 Power Terminations PE PE = Pr otectiveEa rt h Gr o und L1 L2/N Figure 4-1 AC Power Terminals
I/O Setup and System Configuration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 5-1 5. I/O Setup and System Configuration 5.1 Overview Introduction This section provides instructions for performing I/O setup and for configuring theAnalyzer/Controller’s software t...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-2 5.2 I/O Setup and Configuration Tasks Ease of configuration Configuring the 9782 software is fast and easy. A menu is provided for every configuration task.You will be p...
I/O Setup and System Configuration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 5-3 • AUTOCLEAN: AutoClean is a feature that lets the Analyzer/Controller periodicallyrinse the cells automatically. Configure control of AutoClean as described in 5.8. • COMPUTED VAL...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-4 5.3 Performing I/O Setup Purpose Before you can configure your Analyzer/Controller to implement your alarm and control strategyyou must perform I/O setup. In I/O setup y...
I/O Setup and System Configuration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 5-5 ATTENTION If you add an option card to the 9782, it is very important that you change the model numberstored in memory (see Section 10). During I/O setup the software will display...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-6 Table 5-1 Procedure for Performing I/O Setup Step Screen Action 1 MENUCONFIGURATIONCALIBRATIONMAINTENANCEI/O SE TU P DIAGNOSTICS | PREV | NEXT Go to I/O SETUP. 2 RELAY S...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-8 Step Screen Action 11 DISPLAY RESOLUTIONRESOLUTION LOWUOM uS DIAGNOSTICS | PREV | NEXT Use this screen to specify the display resolution, LOW(fixed) or HIGH (automatical...
I/O Setup and System Configuration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 5-9 Step Screen Action 13 SOLUTION TEMP COMP C1 ACID/NH3/ETAC2 NACL DIAGNOSTICS | PREV | NEXT Select the type of solution for which temperaturecompensation should be applied. 14 ANALO...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-10 5.4 Configuring Current Adjusting Type (CAT) Control and/orRetransmission of Process Variables Purpose If the hardware supports analog outputs, during I/O setup you had...
I/O Setup and System Configuration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 5-11 Step Screen Action 3 CAT CONTROL CAT1CAT2CAT3 DIAGNOSTICS | PREV | NEXT Select an output to configure it for control. Go to the next screen. 4 CAT CONTROL OUTPUT 1SCALING LINFIXE...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-12 5.5 Configuring On/Off, Duration Adjusting Type (DAT), orPulse Frequency Type (PFT) Control Purpose During I/O setup you had an opportunity to specify whether to use on...
I/O Setup and System Configuration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 5-13 Table 5-3 Procedure for Configuring On/Off Control Step Screen Action 1 MENUCON FIG URATI ONCALIBRATIONMAINTENANCEI/O SETUP DIAGNOSTICS | PREV | NEXT Go to CONFIGURATION | DISCRE...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-14 Table 5-4 Procedure for Configuring PFT Control Step Screen Action 1 MENUCON FIG URATI ONCALIBRATIONMAINTENANCEI/O SETUP DIAGNOSTICS | PREV | NEXT Go to CONFIGURATION |...
I/O Setup and System Configuration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 5-15 Table 5-5 Procedure for Configuring DAT Control Step Screen Action 1 MENUCON FIG URATI ONCALIBRATIONMAINTENANCEI/O SETUP DIAGNOSTICS | PREV | NEXT Go to CONFIGURATION | DISCRETE ...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-16 5.6 Configuring Alarms Purpose If you assigned one or more alarms to at least one relay during I/O setup (described in 5.3), thenfor each alarm select the process value...
I/O Setup and System Configuration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 5-17 5.7 Setting the Clock Purpose A display showing the current time can be accessed when the unit is online. The 24-hour clockmust be set before you can use the AutoClean feature de...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-18 5.8 Configuring AutoClean Purpose The AutoClean feature periodically rinses the cells automatically (see Section 7). If this featurewas selected during I/O setup (descr...
I/O Setup and System Configuration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 5-19 Hold mode During AutoClean operations alarms and outputs are always held. This means that no alarmswill become active during the automatic operation. If one or more relays are be...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-20 Step Screen Action 3 AUTO CLEANTIMER SETUPDAYS 3HOURS 16MINUTES 30CURRENT DAY 2 DIAGNOSTICS | | NEXT Timer setup is used to specify the frequency of the rinses. • If se...
I/O Setup and System Configuration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 5-21 5.9 Selecting a Computed Value to Be Displayed Purpose The Analyzer/Controller can calculate and display a computed value. The available values are: • RATIO: ratio between the va...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-22 Step Screen Action 2 COMPUTED VALUE SELECT DIFFERENCE DIAGNOSTICS | | NEXT Specify the value to be computed.
I/O Setup and System Configuration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 5-23 5.10 Summary of Menu Choices and System Defaults Introduction Table 5-10 contains the menu choices available (or ranges for numeric values) and systemdefaults for I/O assignments...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-24 PARAMETER CHOICES or RANGE (Default is underlined) I/O setup: discrete control enabled NOYES I/O setup: discrete control type for each available relay PFTDATO/F [on/off...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-26 PARAMETER CHOICES or RANGE (Default is underlined) configuration: AutoClean current day 0 to 28, default = 0 configuration: AutoClean rinse durationconfiguration: AutoC...
Input and Output Wiring 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 6-1 6. Input and Output Wiring 6.1 Overview Introduction This section contains instructions for installing input and output wiring for theAnalyzer/Controller. We recommend that you wait to insta...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 6-2 6.2 General Wiring Practices for I/O Wiring WARNING W iring should be performed by qualified personnel only. Safety precaution WARNING A disconnect switch must be instal...
Input and Output Wiring 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 6-3 Recommended maximum wire size Table 6-1 Recommended Maximum Wire Size Gage Number mm 2 Description 14 2.081 power and relays see Parts List 0.823 inputs* 18 0.823 isolated outputs * Automati...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 6-4 6.3 Wiring Analog Inputs and Outputs Introduction Every 9782 Analyzer/Controller requires input signals from the cells. In addition, some 9782 models provide from one to...
Input and Output Wiring 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 6-5 Table 6-2 Procedure for Installing Analog I/O Wiring Step Action 1 Go to I/O SETUP to view the displays showing analog input, relay, and analog output use.Note the assignments shown. You mus...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 6-6 9 SH G R G R W K W K N C C O M N ON C C O MN O L1 (K) L 2 / N Rel ay 2Note 1 Rel ay 1Note 1 120V/240 V15 A50-6 0 HzNot e 5 Power &Relay Terminals No. 2 Temp. Compens...
Input and Output Wiring 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 6-7 6.4 Wiring Relays 6.4.1 Installation Introduction Every 9782 model includes two relay outputs that can be used with special features such asAutoClean and output range status indication, or t...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 6-8 WARNING While the unit is powered, a potentially lethal shock hazard exists inside the case. Do notopen the case while the unit is powered. More than one switch may be r...
Input and Output Wiring 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 6-9 6.4.2 Disconnecting RC Arc Suppression Circuits Introduction Relay contacts are protected by RC arc suppression circuits. Alternating current leakage throughthese circuits may be sufficient ...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 6-10 6.4.3 Wiring a Device to the Relay Indicating Output Range Status Introduction If the automatic output range change feature is selected during I/O setup, one relay is d...
Input and Output Wiring 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 6-11 9 8 7 6 5 4 3 2 1 - mA + +10 VC +1 9782 Conductivity Analyzer NO NC R R 1 3 5 2 4 6 1 3 5 2 4 6 Multi-point Recorder Input Terminal Board a/n 23179 where R = 250 ohms Figure 6-3 Interconnec...
AutoClean Theory and Piping 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7-1 7. AutoClean Theory and Piping 7.1 Overview Introduction The AutoClean feature periodically rinses the cells automatically as described in this section. Totake advantage of this feature ...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 7-2 7.2 AutoClean Sequence and Piping Rinse sequence The AutoClean operation occurs at the configured intervals. (It can also be initiated by theoperator; see Sub-Section 5....
AutoClean Theory and Piping 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7-3 Automatic Wash Setup AutoClean Operation Interval Between Rinses (days or hours) 0.588" 0.222" 1.709" Normal Operation Resume Delay Time (seconds) Rinse Duration (seconds)Rel...
Calibration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 8-1 8. Calibration 8.1 Overview Introduction Each type of cell has an associated cell constant entered during I/O setup (see Section 5). Thisnumber is part of the cell model number. However, for greater pre...
Calibration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 8-3 8.2 Recommendations for Successful Measurement and Calibration Selection and care of cell essential Successful measurements and calibration depend upon selection and care of the cells. Alwaysprepare cel...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 8-4 8.3 Entering the Cal Factor for Each Cell Introduction Each type of cell has an associated cell constant; this number is part of the cell model number.The constant for e...
Calibration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 8-5 8.4 Performing Calibration Trim Introduction For most applications entering the cal factor for each cell will achieve satisfactory systemperformance. However, it is possible to perform a calibration tri...
Calibration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 8-7 8.5 Removing Calibration Trim Values Introduction If the calibration is suspect, or if the system operation is being checked using a reference resistoras described in Appendix D, remove the calibration ...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 8-8 8.6 Determining and Entering the TDS Conversion Factor Introduction The 9782 always measures conductivity. However, the process value can be displayed in termsof total d...
Calibration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 8-9 Next, perform the calibration. Once calibration has been completed, go back to I/O setup and setthe solution temperature compensation type to the TDS choice, for example “NaCl (TDS)”. At this point you ...
Diagnostics and Messages 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 9-1 9. Diagnostics and Messages 9.1 Overview Introduction This section contains information on status and alarm messages, as well as on diagnostics andsystem error messages. All these messages ...
Diagnostics and Messages 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 9-3 9.3 Process Alarm Messages Alarms dependent on configuration Alarms are configurable as described in Section 5. When an alarm is active, it is alwaysdisplayed on the alarm stripe. All avail...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 9-4 9.4 On-Line Diagnostics and System Error Messages Self-tests at 0.5 second intervals On-line diagnostics are self-tests which are performed automatically as a background...
Diagnostics and Messages 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 9-5 9.5 Off-Line Diagnostics Introduction The following off-line diagnostics can be initiated by the operator: • display test (see 9.5.1) • keyboard test (see 9.5.1) • output tests (see 9.5.2) ...
Diagnostics and Messages 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 9-7 9.5.2 Output Tests Procedure Use the procedure in Table 9-5 to test the relays and analog outputs. Testing the analog outputs requires ammeters or voltmeters as appropriate. WARNING W hile ...
Maintenance 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 10-1 10. Maintenance 10.1 Overview Introduction This section provides instructions for a variety of maintenance tasks. What’s in this section? The topics in this section are listed below. Topic See Page 10....
Maintenance 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 10-3 10.2 Output Calibration Introduction The 9782 is available with one or more optional analog outputs. The output signals can beadjusted to trim the high and low output current or voltage values over a r...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 10-4 Table 10-1 Procedure for Calibrating Outputs Step Screen Action 1 Turn off the power to the Analyzer/Controller. More thanone switch may be required to disconnect power...
Maintenance 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 10-5 Step Screen Action 8 OUTP UT 1 S PA NOUTPUT1 ZEROOUTPUT2 SPANOUTPUT2 ZEROOUTPUT3 SPANOUTPUT3 ZERO DIAGNOSTICS | | The first display will reflect the quantity of analog outputssupported by the hardware....
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 10-6 10.3 Specifying a Tagname or Other Display String Introduction The real-time displays of process values show the instrument’s tagname (or other configurablefixed ninete...
Maintenance 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 10-7 10.4 Viewing Product Information and Changing Model NumberStored in Memory Introduction During I/O setup (see Section 5) the software will display prompts only for those features thehardware can suppor...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 10-8 Step Screen Action 2 PRODUCT INFORMATION SOFTWARE VER: A1.0MODEL NUMBER:9782X-nn-Xn-XXXX DIAGNOSTICSEDIT | | The software version is read-only information. If the model...
Maintenance 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 10-9 10.5 Adjusting the Screen Contrast Introduction The display contrast can be adjusted to suit the viewing conditions at the installation site. Procedure To adjust the display contrast, follow the proced...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 10-10 10.6 Entering a Password for Security Introduction I/O setup, configuration, calibration and maintenance functions can be password-protected. Thepassword can be any nu...
Maintenance 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 10-11 10.7 Resetting All Configuration and Calibration Values to FactorySettings Introduction A “cold reset” function is available to return ALL configuration values to the factory settingsshown in Table 5-...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 10-12 10.8 Entering Values for Lead Resistance Compensation (Wide RangeOnly) Introduction If you use standard Honeywell cell lead lengths of 7 or 20 feet connected directly ...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 10-14 10.9 Replacing the Fuse Introduction Figure 10-1 shows the location of the power fuse on the power supply card in the right-mostposition inside the case. (See Section ...
Maintenance 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 10-15 Table 10-8 Procedure for Replacing the Fuse Step Action 1 Determine why the fuse blew and correct the problem. 2 Check the fuse’s packaging (in miscellaneous parts kit 51198177-501) to be sure that th...
Accessories and Replacement Parts List 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 11-1 11. Accessories and Replacement Parts List 11.1 Overview Introduction This section provides part numbers for field-replaceable parts and for accessories. What’s in this secti...
Accessories and Replacement Parts List 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 11-3 Kit/Part Number Description Parts Included in Kit Quantity PARTS USED BY CONDUCTIVITY 9782 ANALYZER ONLY 51198066-503 For upgrade of conductivity analyzer card 1 Wide Range: ...
Proportional Control Tuning 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual Appendix A - 1 Appendix A Proportional Control Tuning Adjust effective proportional band width The only adjustment in proportional-only control is the effective proportional band width. Fors...
Two-Cell Applications 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual Appendix B - 1 Appendix B Two-Cell Applications Ion Exchange Ion exchange operations can achieve especially precise control using the conductivity ratio oftwo points with each bed. Ratio measureme...
Conductivity/Resistivity Analyzer/Controller Appendix B - 2 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 Conductivity/Resistivity/TDS Difference Conductivity/Resistivity/TDS difference using redundant cells on critical processes can provide avaluable diagnostic c...
Two-Cell Applications 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual Appendix B - 3 Softener Monitoring Softener monitoring by conductivity ratio gives a continuous indication of performance. Sodiumis typically more conductive than the hardness minerals it displace...
Microprocessor Board Switch Settings 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual Appendix C - 1 Appendix C Microprocessor Board Switch Settings Introduction The information in this appendix will not be needed for normal set up and operation of the 9782Analyzer/C...
Conductivity/Resistivity Analyzer/Controller Appendix C - 2 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 Table C-1 Microprocessor Board Switch Settings Option SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 None OFF OFF OFF OFF OFF OFF OFF OFF SingleParameterCurr...
Using a Precision Check Resistor 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual Appendix D - 1 Appendix D Using a Precision Check Resistor Introduction The operation of the Analyzer/Controller can be verified by replacing the input from a cell with aprecision check...
Conductivity/Resistivity Analyzer/Controller Appendix D - 2 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 Example 1: To determine the check resistor value needed to simulate conductivity measurementof 10 µ S, use cell constant 0.1 and perform the following calcula...
Industrial Automation and Control Honeywell, Inc.1100 Virginia DriveFort Washington, Pennsylvania 19034
Manual Honeywell 9782 Series
Summary
9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 6/99 ii Copyright, Notices, and Trademarks Printed in U.S.A. – © Copyright 1999 by Honeywell Inc. Revision 3 – 6/99 W hile this information is presented in good faith and believed to be accurate, Honeywelldisclaims the impl...
6/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual iii About This Document Abstract This manual contains instructions for installation and operation of the 9782 SeriesConductivity/Resistivity Analyzer/Controller. Revision Notes The following list provides notes concern...
9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 6/99 iv Contents 1. INTRODUCTION ..................................................................................................... 1-1 1.1 Description .......................................................................
6/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual vii 5.9 Selecting a Computed Value to Be Displayed ............................................................................. 5-21 Purpose ...............................................................................
9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 6/99 viii 8. CALIBRATION ........................................................................................................ 8-1 8.1 Overview ...............................................................................
6/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual ix 10. MAINTENANCE................................................................................................... 10-1 10.1 Overview ....................................................................................
6/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual xi Tables Table 1-1 Key Functions .......................................................................................................................... 1-6Table 1-2 9782 Conductivity/Resistivity Analyzer/Controlle...
9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 6/99 xii Table 10-8 Procedure for Replacing the Fuse ...................................................................................... 10-16 Table 11-1 Part Numbers ........................................................
6/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual xiii Figures Figure 1-1 9782 Front Panel..................................................................................................................... 1-5Figure 1-2 Representative Process Value Display for a Cel...
9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 6/99 xiv
Introduction 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 1-1 1. Introduction 1.1 Description Multi-function instrument The Honeywell 9782 Conductivity/Resistivity Analyzer/Controller (Figure 1-1) is amicroprocessor-based instrument for analysis of conductivity, ...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 1-2 Input Input to the 9782 can be from any Honeywell conductivity cell at distances up to 1500 feet. Outputs Optional isolated 0 to 1 V, 0 to 10 V and 4 to 20 mA outputs ar...
Introduction 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 1-3 1.2 Features Automatic cell washing The standard AutoClean feature can periodically rinse cells automatically. The schedule andduration of the operation are configurable. An internal relay actuates ext...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 1-4 Watertight corrosion-resistant case The 9782 is enclosed in a watertight and corrosion resistant industrial case, designed for panel,pipe or wall mounting. It has an EMI...
Introduction 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 1-7 Selecting a parameter for edit To select a parameter for edit: • display the screen containing the parameter • use the UP or DOWN keys to highlight the parameter name • press the ENTER key to highlight...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 1-8 1.3.2 Online Displays Introduction The online displays available when the operator presses the DISPLAY key depend on thenumber of cells connected to the Analyzer/Control...
Introduction 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 1-9 Combined display If two cells are connected to the Analyzer/Controller, then a display is available that includes themeasured variable for both cells (see Figure 1-3). Another combined display also inc...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 1-10 Clock and AutoClean If the 24-hour clock is turned on, a time display will be available. If AutoClean is configured,then the AutoClean screen will be included in the di...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 1-12 Table 1-2 9782 Conductivity/Resistivity Analyzer/Controller Menu Hierarchy Menu Item Purpose Where Described MAINTENANCE do occasional system tasks Sections 9 and 10 OF...
Introduction 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 1-13 1.5 Planning 1.5.1 Overview Configuration system minimizes decisions The 9782C Analyzer/Controller was designed for easy configuration using menu displays and thekeys on the front panel. Numeric value...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 1-14 Interactions affecting permitted relay assignments Table 1-3 is provided so that you can optimize your use of relays to implement your controlstrategy. Each row in the ...
Introduction 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 1-15 Table 1-3 Available Combinations of Relay Assigments Features Used Relay 1 Relay 2 Relay 3 Relay 4 Alarm 1 Alarm 2 Alarm 3 Alarm 4 Alarm 1 and Diagnostic Alarm 2 Alarm 3 Alarm 4 Alarms Only Alarm 1 Al...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 1-16 1.5.3 Deciding on a Control Strategy All 9782 models can use relays for control All 9782 models have at least two relays. (Two more relays are optional.) Unless dedicat...
Introduction 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 1-17 1.6 Overview of Installation and Setup Tasks Setup tasks described in this manual This manual contains instructions for all installation and operation tasks relating to theAnalyzer/Controller. (Instru...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 1-18 The manual also contains: • information about diagnostics, status messages, and system error messages(Section 9) • instructions for returning all parameter values to th...
Specifications and Model Number 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 2-1 2. Specifications and Model Number 2.1 Specifications 2.1.1 User Interface Display LCD dot matrix display, 128 by 64 dpi. Backlit: solid state LED. Displays Cell 1 and Cell 2values i...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 2-2 CE conformity This product is in conformance with the protection requirements of the following EuropeanCouncil Directives: 89/336/EEC, the Electromagnetic Compatibility ...
Specifications and Model Number 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 2-3 Wide range models Wide Display Ranges: 9782C-W0 Conductivity (microsiemens/cm) TDS Cell Constant Required (cm-1) 100-1,999 0-1,999 ppm 0.1 1000-19,990 0-19,990 ppm 1 Conductivity (mi...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 2-4 Performance under reference operating conditions Display Accuracy: Standard Ranges (Conductivity/Resistivity); ±0.5% of reading. Wide Ranges (Conductivity); ±0.5% of rea...
Specifications and Model Number 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 2-5 2.1.8 Temperature Compensation Availability All models can provide high resolution (0.05º C, typical) temperature compensation bymicroprocessor calculation over 0 to 140º C for high ...
Specifications and Model Number 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 2-7 2.2 Model Number Breakdown Introduction The model number breakdown is presented in the tables that follow. The basic model number consists of a key number. Appended to this key numbe...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 2-8 TABLE I - INPUTSpH/ORP ElectrodespH from External Pre-amp 01 Direct Glass/Antimony pH/ORP Electrode/Internal Pre-amp 02 Direct DURAFET pH electrode, Internal Pre-amp 03 ...
Unpacking, Preparation, and Mounting 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 3-1 3. Unpacking, Preparation, and Mounting 3.1 Overview Introduction This section contains instructions for unpacking, preparing, and mounting theAnalyzer/Controller. Instructions ...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 3-2 3.2 Unpacking and Preparing Procedure Table 3-1 contains procedure for unpacking and preparing the 9782. Table 3-1 Procedure for Unpacking and Preparing the 9782 Step Ac...
Unpacking, Preparation, and Mounting 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 3-3 Honeywell York, PA U.S.A. ATTENTION - UNIT SET FOR 240 VAC 9782C-S0-VC-E0010-00S/N: 9751Y712345670001USA WARRANTY ASSISTANCE - 1 - 800-423-9883 120/240 VAC 50/60 Hz 15VAContact ...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 3-4 Figure 3-2-1 Mounting and Dimensions – Non-Backlit Display Option 7.68 ± .060 195.07 ± 1.52 3.06 77.80 7.43 ± .070 188.72 ± 1.78 1.0025.40 IPS Pipe(by customer) Note 1: ...
Unpacking, Preparation, and Mounting 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 3-5 Figure 3-2-2 Mounting and Dimensions – Non-Backlit Display Option 6.43 ±0.70 163.32 ±1.78 C L 1.00 ±.025 25.40 ±0.64 6.27 ±.040 159.26 ±1.02 .12 min. 3.04 .37 max. 9.40 3.31 84....
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 3-6 7.68 ± .060 195.07 ± 1.52 3.06 77.80 7.64 ± .070 194.06 ± 1.78 1.0025.40 IPS Pipe(by customer) Note 1: Do not exceed 80 lb-in torque when tightening fastners. Horizontal...
Unpacking, Preparation, and Mounting 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 3-7 Figure 3-3-2 Mounting and Dimensions – Backlit Display Option 6.43 ±0.70 163.32 ±1.78 C L 1.21 ±.025 30.73 ±0.64 6.27 ±.040 159.26 ±1.02 .12 min. 3.04 .37 max. 9.40 3.31 84.07 6...
Power Wiring 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 4-1 4. Power Wiring 4.1 Overview Introduction This section contains instructions for installing ac power wiring for the Analyzer/Controller, inpreparation for configuring the software and performing I/O se...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 4-2 4.2 General Wiring Practices for Power Wiring WARNING W iring should be performed by qualified personnel only. Safety precautions WARNING A disconnect switch must be ins...
Power Wiring 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 4-3 4.3 Power Wiring Considerations Recommended wire size Observe all national and local electrical codes when making power connections. Unless locallyapplicable codes dictate otherwise, use 14 gauge (2.08...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 4-4 4.4 Installing Power Wiring Procedure Follow the procedure in Table 4-1 to install AC power wiring. WARNING Turn power off at mains before installing AC power wiring. Ta...
Power Wiring 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 4-5 Power Terminations PE PE = Pr otectiveEa rt h Gr o und L1 L2/N Figure 4-1 AC Power Terminals
I/O Setup and System Configuration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 5-1 5. I/O Setup and System Configuration 5.1 Overview Introduction This section provides instructions for performing I/O setup and for configuring theAnalyzer/Controller’s software t...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-2 5.2 I/O Setup and Configuration Tasks Ease of configuration Configuring the 9782 software is fast and easy. A menu is provided for every configuration task.You will be p...
I/O Setup and System Configuration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 5-3 • AUTOCLEAN: AutoClean is a feature that lets the Analyzer/Controller periodicallyrinse the cells automatically. Configure control of AutoClean as described in 5.8. • COMPUTED VAL...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-4 5.3 Performing I/O Setup Purpose Before you can configure your Analyzer/Controller to implement your alarm and control strategyyou must perform I/O setup. In I/O setup y...
I/O Setup and System Configuration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 5-5 ATTENTION If you add an option card to the 9782, it is very important that you change the model numberstored in memory (see Section 10). During I/O setup the software will display...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-6 Table 5-1 Procedure for Performing I/O Setup Step Screen Action 1 MENUCONFIGURATIONCALIBRATIONMAINTENANCEI/O SE TU P DIAGNOSTICS | PREV | NEXT Go to I/O SETUP. 2 RELAY S...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-8 Step Screen Action 11 DISPLAY RESOLUTIONRESOLUTION LOWUOM uS DIAGNOSTICS | PREV | NEXT Use this screen to specify the display resolution, LOW(fixed) or HIGH (automatical...
I/O Setup and System Configuration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 5-9 Step Screen Action 13 SOLUTION TEMP COMP C1 ACID/NH3/ETAC2 NACL DIAGNOSTICS | PREV | NEXT Select the type of solution for which temperaturecompensation should be applied. 14 ANALO...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-10 5.4 Configuring Current Adjusting Type (CAT) Control and/orRetransmission of Process Variables Purpose If the hardware supports analog outputs, during I/O setup you had...
I/O Setup and System Configuration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 5-11 Step Screen Action 3 CAT CONTROL CAT1CAT2CAT3 DIAGNOSTICS | PREV | NEXT Select an output to configure it for control. Go to the next screen. 4 CAT CONTROL OUTPUT 1SCALING LINFIXE...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-12 5.5 Configuring On/Off, Duration Adjusting Type (DAT), orPulse Frequency Type (PFT) Control Purpose During I/O setup you had an opportunity to specify whether to use on...
I/O Setup and System Configuration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 5-13 Table 5-3 Procedure for Configuring On/Off Control Step Screen Action 1 MENUCON FIG URATI ONCALIBRATIONMAINTENANCEI/O SETUP DIAGNOSTICS | PREV | NEXT Go to CONFIGURATION | DISCRE...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-14 Table 5-4 Procedure for Configuring PFT Control Step Screen Action 1 MENUCON FIG URATI ONCALIBRATIONMAINTENANCEI/O SETUP DIAGNOSTICS | PREV | NEXT Go to CONFIGURATION |...
I/O Setup and System Configuration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 5-15 Table 5-5 Procedure for Configuring DAT Control Step Screen Action 1 MENUCON FIG URATI ONCALIBRATIONMAINTENANCEI/O SETUP DIAGNOSTICS | PREV | NEXT Go to CONFIGURATION | DISCRETE ...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-16 5.6 Configuring Alarms Purpose If you assigned one or more alarms to at least one relay during I/O setup (described in 5.3), thenfor each alarm select the process value...
I/O Setup and System Configuration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 5-17 5.7 Setting the Clock Purpose A display showing the current time can be accessed when the unit is online. The 24-hour clockmust be set before you can use the AutoClean feature de...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-18 5.8 Configuring AutoClean Purpose The AutoClean feature periodically rinses the cells automatically (see Section 7). If this featurewas selected during I/O setup (descr...
I/O Setup and System Configuration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 5-19 Hold mode During AutoClean operations alarms and outputs are always held. This means that no alarmswill become active during the automatic operation. If one or more relays are be...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-20 Step Screen Action 3 AUTO CLEANTIMER SETUPDAYS 3HOURS 16MINUTES 30CURRENT DAY 2 DIAGNOSTICS | | NEXT Timer setup is used to specify the frequency of the rinses. • If se...
I/O Setup and System Configuration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 5-21 5.9 Selecting a Computed Value to Be Displayed Purpose The Analyzer/Controller can calculate and display a computed value. The available values are: • RATIO: ratio between the va...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-22 Step Screen Action 2 COMPUTED VALUE SELECT DIFFERENCE DIAGNOSTICS | | NEXT Specify the value to be computed.
I/O Setup and System Configuration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 5-23 5.10 Summary of Menu Choices and System Defaults Introduction Table 5-10 contains the menu choices available (or ranges for numeric values) and systemdefaults for I/O assignments...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-24 PARAMETER CHOICES or RANGE (Default is underlined) I/O setup: discrete control enabled NOYES I/O setup: discrete control type for each available relay PFTDATO/F [on/off...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 5-26 PARAMETER CHOICES or RANGE (Default is underlined) configuration: AutoClean current day 0 to 28, default = 0 configuration: AutoClean rinse durationconfiguration: AutoC...
Input and Output Wiring 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 6-1 6. Input and Output Wiring 6.1 Overview Introduction This section contains instructions for installing input and output wiring for theAnalyzer/Controller. We recommend that you wait to insta...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 6-2 6.2 General Wiring Practices for I/O Wiring WARNING W iring should be performed by qualified personnel only. Safety precaution WARNING A disconnect switch must be instal...
Input and Output Wiring 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 6-3 Recommended maximum wire size Table 6-1 Recommended Maximum Wire Size Gage Number mm 2 Description 14 2.081 power and relays see Parts List 0.823 inputs* 18 0.823 isolated outputs * Automati...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 6-4 6.3 Wiring Analog Inputs and Outputs Introduction Every 9782 Analyzer/Controller requires input signals from the cells. In addition, some 9782 models provide from one to...
Input and Output Wiring 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 6-5 Table 6-2 Procedure for Installing Analog I/O Wiring Step Action 1 Go to I/O SETUP to view the displays showing analog input, relay, and analog output use.Note the assignments shown. You mus...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 6-6 9 SH G R G R W K W K N C C O M N ON C C O MN O L1 (K) L 2 / N Rel ay 2Note 1 Rel ay 1Note 1 120V/240 V15 A50-6 0 HzNot e 5 Power &Relay Terminals No. 2 Temp. Compens...
Input and Output Wiring 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 6-7 6.4 Wiring Relays 6.4.1 Installation Introduction Every 9782 model includes two relay outputs that can be used with special features such asAutoClean and output range status indication, or t...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 6-8 WARNING While the unit is powered, a potentially lethal shock hazard exists inside the case. Do notopen the case while the unit is powered. More than one switch may be r...
Input and Output Wiring 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 6-9 6.4.2 Disconnecting RC Arc Suppression Circuits Introduction Relay contacts are protected by RC arc suppression circuits. Alternating current leakage throughthese circuits may be sufficient ...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 6-10 6.4.3 Wiring a Device to the Relay Indicating Output Range Status Introduction If the automatic output range change feature is selected during I/O setup, one relay is d...
Input and Output Wiring 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 6-11 9 8 7 6 5 4 3 2 1 - mA + +10 VC +1 9782 Conductivity Analyzer NO NC R R 1 3 5 2 4 6 1 3 5 2 4 6 Multi-point Recorder Input Terminal Board a/n 23179 where R = 250 ohms Figure 6-3 Interconnec...
AutoClean Theory and Piping 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7-1 7. AutoClean Theory and Piping 7.1 Overview Introduction The AutoClean feature periodically rinses the cells automatically as described in this section. Totake advantage of this feature ...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 7-2 7.2 AutoClean Sequence and Piping Rinse sequence The AutoClean operation occurs at the configured intervals. (It can also be initiated by theoperator; see Sub-Section 5....
AutoClean Theory and Piping 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7-3 Automatic Wash Setup AutoClean Operation Interval Between Rinses (days or hours) 0.588" 0.222" 1.709" Normal Operation Resume Delay Time (seconds) Rinse Duration (seconds)Rel...
Calibration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 8-1 8. Calibration 8.1 Overview Introduction Each type of cell has an associated cell constant entered during I/O setup (see Section 5). Thisnumber is part of the cell model number. However, for greater pre...
Calibration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 8-3 8.2 Recommendations for Successful Measurement and Calibration Selection and care of cell essential Successful measurements and calibration depend upon selection and care of the cells. Alwaysprepare cel...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 8-4 8.3 Entering the Cal Factor for Each Cell Introduction Each type of cell has an associated cell constant; this number is part of the cell model number.The constant for e...
Calibration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 8-5 8.4 Performing Calibration Trim Introduction For most applications entering the cal factor for each cell will achieve satisfactory systemperformance. However, it is possible to perform a calibration tri...
Calibration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 8-7 8.5 Removing Calibration Trim Values Introduction If the calibration is suspect, or if the system operation is being checked using a reference resistoras described in Appendix D, remove the calibration ...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 8-8 8.6 Determining and Entering the TDS Conversion Factor Introduction The 9782 always measures conductivity. However, the process value can be displayed in termsof total d...
Calibration 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 8-9 Next, perform the calibration. Once calibration has been completed, go back to I/O setup and setthe solution temperature compensation type to the TDS choice, for example “NaCl (TDS)”. At this point you ...
Diagnostics and Messages 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 9-1 9. Diagnostics and Messages 9.1 Overview Introduction This section contains information on status and alarm messages, as well as on diagnostics andsystem error messages. All these messages ...
Diagnostics and Messages 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 9-3 9.3 Process Alarm Messages Alarms dependent on configuration Alarms are configurable as described in Section 5. When an alarm is active, it is alwaysdisplayed on the alarm stripe. All avail...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 9-4 9.4 On-Line Diagnostics and System Error Messages Self-tests at 0.5 second intervals On-line diagnostics are self-tests which are performed automatically as a background...
Diagnostics and Messages 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 9-5 9.5 Off-Line Diagnostics Introduction The following off-line diagnostics can be initiated by the operator: • display test (see 9.5.1) • keyboard test (see 9.5.1) • output tests (see 9.5.2) ...
Diagnostics and Messages 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 9-7 9.5.2 Output Tests Procedure Use the procedure in Table 9-5 to test the relays and analog outputs. Testing the analog outputs requires ammeters or voltmeters as appropriate. WARNING W hile ...
Maintenance 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 10-1 10. Maintenance 10.1 Overview Introduction This section provides instructions for a variety of maintenance tasks. What’s in this section? The topics in this section are listed below. Topic See Page 10....
Maintenance 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 10-3 10.2 Output Calibration Introduction The 9782 is available with one or more optional analog outputs. The output signals can beadjusted to trim the high and low output current or voltage values over a r...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 10-4 Table 10-1 Procedure for Calibrating Outputs Step Screen Action 1 Turn off the power to the Analyzer/Controller. More thanone switch may be required to disconnect power...
Maintenance 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 10-5 Step Screen Action 8 OUTP UT 1 S PA NOUTPUT1 ZEROOUTPUT2 SPANOUTPUT2 ZEROOUTPUT3 SPANOUTPUT3 ZERO DIAGNOSTICS | | The first display will reflect the quantity of analog outputssupported by the hardware....
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 10-6 10.3 Specifying a Tagname or Other Display String Introduction The real-time displays of process values show the instrument’s tagname (or other configurablefixed ninete...
Maintenance 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 10-7 10.4 Viewing Product Information and Changing Model NumberStored in Memory Introduction During I/O setup (see Section 5) the software will display prompts only for those features thehardware can suppor...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 10-8 Step Screen Action 2 PRODUCT INFORMATION SOFTWARE VER: A1.0MODEL NUMBER:9782X-nn-Xn-XXXX DIAGNOSTICSEDIT | | The software version is read-only information. If the model...
Maintenance 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 10-9 10.5 Adjusting the Screen Contrast Introduction The display contrast can be adjusted to suit the viewing conditions at the installation site. Procedure To adjust the display contrast, follow the proced...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 10-10 10.6 Entering a Password for Security Introduction I/O setup, configuration, calibration and maintenance functions can be password-protected. Thepassword can be any nu...
Maintenance 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 10-11 10.7 Resetting All Configuration and Calibration Values to FactorySettings Introduction A “cold reset” function is available to return ALL configuration values to the factory settingsshown in Table 5-...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 10-12 10.8 Entering Values for Lead Resistance Compensation (Wide RangeOnly) Introduction If you use standard Honeywell cell lead lengths of 7 or 20 feet connected directly ...
Conductivity/Resistivity Analyzer/Controller 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 10-14 10.9 Replacing the Fuse Introduction Figure 10-1 shows the location of the power fuse on the power supply card in the right-mostposition inside the case. (See Section ...
Maintenance 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 10-15 Table 10-8 Procedure for Replacing the Fuse Step Action 1 Determine why the fuse blew and correct the problem. 2 Check the fuse’s packaging (in miscellaneous parts kit 51198177-501) to be sure that th...
Accessories and Replacement Parts List 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 11-1 11. Accessories and Replacement Parts List 11.1 Overview Introduction This section provides part numbers for field-replaceable parts and for accessories. What’s in this secti...
Accessories and Replacement Parts List 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 11-3 Kit/Part Number Description Parts Included in Kit Quantity PARTS USED BY CONDUCTIVITY 9782 ANALYZER ONLY 51198066-503 For upgrade of conductivity analyzer card 1 Wide Range: ...
Proportional Control Tuning 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual Appendix A - 1 Appendix A Proportional Control Tuning Adjust effective proportional band width The only adjustment in proportional-only control is the effective proportional band width. Fors...
Two-Cell Applications 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual Appendix B - 1 Appendix B Two-Cell Applications Ion Exchange Ion exchange operations can achieve especially precise control using the conductivity ratio oftwo points with each bed. Ratio measureme...
Conductivity/Resistivity Analyzer/Controller Appendix B - 2 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 Conductivity/Resistivity/TDS Difference Conductivity/Resistivity/TDS difference using redundant cells on critical processes can provide avaluable diagnostic c...
Two-Cell Applications 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual Appendix B - 3 Softener Monitoring Softener monitoring by conductivity ratio gives a continuous indication of performance. Sodiumis typically more conductive than the hardness minerals it displace...
Microprocessor Board Switch Settings 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual Appendix C - 1 Appendix C Microprocessor Board Switch Settings Introduction The information in this appendix will not be needed for normal set up and operation of the 9782Analyzer/C...
Conductivity/Resistivity Analyzer/Controller Appendix C - 2 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 Table C-1 Microprocessor Board Switch Settings Option SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 None OFF OFF OFF OFF OFF OFF OFF OFF SingleParameterCurr...
Using a Precision Check Resistor 7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual Appendix D - 1 Appendix D Using a Precision Check Resistor Introduction The operation of the Analyzer/Controller can be verified by replacing the input from a cell with aprecision check...
Conductivity/Resistivity Analyzer/Controller Appendix D - 2 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual 7/99 Example 1: To determine the check resistor value needed to simulate conductivity measurementof 10 µ S, use cell constant 0.1 and perform the following calcula...
Industrial Automation and Control Honeywell, Inc.1100 Virginia DriveFort Washington, Pennsylvania 19034
Honeywell Manuals
-
Honeywell DT8050A
Installation Manual
-
Honeywell DT8050A
Manual
-
Honeywell DT8050A
User Manual
-
Honeywell DT8050
Manual
-
Honeywell DT8050
User Manual
-
Honeywell TPFIT25WK
User Manual
-
Honeywell TPFIT25AWK
User Manual
-
Honeywell TPFIT32WK
User Manual
-
Honeywell TPFIT32AWK
User Manual
-
Honeywell 24DX47
User Manual
-
Honeywell 24DX47
Manual
-
Honeywell TPFIT50PWK
User Manual
-
Honeywell TPFIT50WK
User Manual
-
Honeywell TPFIT50AWK
User Manual
-
Honeywell TPFIT50APWK
User Manual
-
Honeywell 00010
User Manual
-
Honeywell ADVBLEWIFI
Manual
-
Honeywell ADVBLEWIFI
User Manual
-
Honeywell ADVBLE
Manual
-
Honeywell ADVBLE
User Manual