Page 2 - Model OFE/OFG/OEA/OGA-341, 342; LIMIT CONTROL
Model OFE/OFG/OEA/OGA-341, 342 1-3. HIGH TEMPERATURE 2. Using a Phillip’s head screwdriver, remove the screws securing LIMIT CONTROL the inner heat shield and remove from unit. Figure 2-3. (Gas Units) (Continued) Figure 2-3 3. Remove the screw securing the high limit bracket to the frame and remove ...
Page 4 - When plugging connectors onto new control panel, be sure the
Model OFE/OFG/OEA/OGA-341, 342 2-4. COMPLETE CONTROL Should the control board become inoperative, follow these PANEL REPLACEMENT instructions for replacing the board. 1. Remove electrical power supplied to the unit. To avoid electrical shock or property damage, move the power switch to OFF and disco...
Page 5 - To avoid electrical shock or property damage, move the
Model OFE/OFG/OEA/OGA-341, 342 2-5. POWER SWITCH (Continued) 4. With control panel removed, and the wires off the switch, push in on tabs on the switch to remove from panel. Figure 2-12. 5. Replace with new switch, and reconnect wires to switch. 6. Replace the control panel. Figure 2-12 2-6. TEMPERA...
Page 6 - Excess force will damage probe.
Model OFE/OFG/OEA/OGA-341, 342 2-6. TEMPERATURE PROBE 5. Remove the probe from the frypot, and disconnect wire REPLACEMENT (GAS) connector from the control panel. Figure 2-15. (Continued) 6. Place the nut and new ferrule on the new probe and insert the probe into the compression fitting until it ext...
Page 8 - PILOT / IGNITOR
Model OFE/OFG/OEA/OGA-341, 342 2-8. FLAME SENSOR/ PILOT / IGNITOR ASSEMBLY (Gas) (Continued) 2. Remove the control panel and heat shield from control area. Figure 2-19. Figure 2-19 3. Disconnect the flame sense wire from ignition module. Figure 2-20. Figure 2-20 4. Using a 7/16” wrench, loosen the n...
Page 11 - REPLACEMENT; To avoid property damage, do not tamper with, or disas semble
Model OFE/OFG/OEA/OGA-341, 342 2-12. VACUUM SWITCH This switch senses the airflow from the induction blower. If REPLACEMENT the airflow is reduced below a set amount, the switch opens and the I/O board cuts power to the gas control valve, which shuts the pilot flame off. 1. Remove electrical power s...
Page 14 - Figure; Figure; Using a 1-inch wrench, loosen the nut securing the main gas; Figure
Model OFE/OFG/OEA/OGA-341, 342 2-15. GAS CONTROL VALVE REPLACEMENT (Continued) 1. Remove right side panel. Figure 2-37. Figure 2-37 2. Label and remove wires from gas valve. Figure 2-38 Figure 2-38 3. Using a 7/16 wrench, remove the pilot line from the gas valve. Figure 2-39. Figure 2-39 4. Using a ...
Page 16 - Remove the wire cover from the blower motor housing.
Model OFE/OFG/OEA/OGA-341, 342 2-16. BLOWER MOTOR REPLACEMENT (Continued) 3. Remove the wire cover from the blower motor housing. Figure 2-44. Figure 2-44 4. Remove wire nuts connecting blower motor wires to wires in conduit. Figure 2-45. Figure 2-45 5. Loosen conduit from blower motor. Figure 2-46....
Page 18 - Wire; Heating elements should never be energized without
Model OFE/OFG/OEA/OGA-341, 342 2-17. HEATING ELEMENTS 4. Perform an ohm check on one element at a time, with wires (ELECTRIC) disconnected. The 2 elements actually have 3 small heating (Continued) elements inside the outer plate. It’s important to check between the correct wires to obtain an accurat...
Page 19 - Heat
Model OFE/OFG/OEA/OGA-341, 342 2-18. HEATING Each well of an electric fryer requires two switching contactors. CONTACTORS The first in line is the primary contactor and the second in line is (ELECTRIC) the heat contactor. When open, the primary contactor does not allow power to flow to the heat cont...
Page 26 - MOTOR
Model OFE/OFG/OEA/OGA-341, 342 2-21. FILTER PUMP AND 1. Remove electrical power supplied to unit. MOTOR REMOVAL To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle. 2. Open the door (left door on 2 well uni...
Page 29 - Using 7/16” socket, remove the 4 nuts securing the support
Model OFE/OFG/OEA/OGA-341, 342 2-24. AUTOLIFT ACTUATOR (MOTOR) REPLACEMENT (if applicable) 5. Disconnect actuator connector. Figure 2-80. Figure 2-80 6. Remove female connector from plate. Figure 2-81. Figure 2-81 Figure 2-82 7. Using 7/16” socket, remove the 4 nuts securing the support plate. 2 nut...
Page 30 - Remove the 2 top screws securing the support plate and
Model OFE/OFG/OEA/OGA-341, 342 2-24. AUTOLIFT ACTUATOR (MOTOR) REPLACEMENT (if applicable) 8. Remove the 2 top screws securing the support plate and remove the plate from the unit. Figure 2-84. Figure 2-84 9. Using a 15T torx driver, remove the 2 torx screws from the back shroud, and pull the actuat...