Page 2 - Model OFE/OFG/OEA/OGA-341, 342; LIMIT CONTROL

Model OFE/OFG/OEA/OGA-341, 342 1-3. HIGH TEMPERATURE 2. Using a Phillip’s head screwdriver, remove the screws securing LIMIT CONTROL the inner heat shield and remove from unit. Figure 2-3. (Gas Units) (Continued) Figure 2-3 3. Remove the screw securing the high limit bracket to the frame and remove ...

Page 4 - When plugging connectors onto new control panel, be sure the

Model OFE/OFG/OEA/OGA-341, 342 2-4. COMPLETE CONTROL Should the control board become inoperative, follow these PANEL REPLACEMENT instructions for replacing the board. 1. Remove electrical power supplied to the unit. To avoid electrical shock or property damage, move the power switch to OFF and disco...

Page 5 - To avoid electrical shock or property damage, move the

Model OFE/OFG/OEA/OGA-341, 342 2-5. POWER SWITCH (Continued) 4. With control panel removed, and the wires off the switch, push in on tabs on the switch to remove from panel. Figure 2-12. 5. Replace with new switch, and reconnect wires to switch. 6. Replace the control panel. Figure 2-12 2-6. TEMPERA...