Henny Penny 342 - Manual
Henny Penny 342 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Model OFE/OFG/OEA/OGA-341, 342; LIMIT CONTROL
- Page 4 – When plugging connectors onto new control panel, be sure the
- Page 5 – To avoid electrical shock or property damage, move the
- Page 6 – Excess force will damage probe.
- Page 8 – PILOT / IGNITOR
- Page 11 – REPLACEMENT; To avoid property damage, do not tamper with, or disas semble
- Page 14 – Figure; Figure; Using a 1-inch wrench, loosen the nut securing the main gas; Figure
- Page 16 – Remove the wire cover from the blower motor housing.
- Page 18 – Wire; Heating elements should never be energized without
- Page 19 – Heat
- Page 26 – MOTOR
- Page 29 – Using 7/16” socket, remove the 4 nuts securing the support
- Page 30 – Remove the 2 top screws securing the support plate and
Model OFE/OFG/OEA/OGA-341, 342
2-1. INTRODUCTION
This section provides procedures for the check out and
replacement of the various parts used within the fryer. Before
replacing any parts refer to the Troubleshooting Section. It will aid
you in determining the cause of the malfunction.
2-2. MAINTENANCE HINTS
1. You may need to use a multimeter to check the electric
components.
2. When the manual refers to the circuit being closed, the
multimeter should read zero unless otherwise noted.
3. When the manual refers to the circuit being open, the
multimeter
will
read
infinity.
2-3. HIGH TEMPERATURE
LIMIT CONTROL
This high temperature control is a safety, manual reset control,
(Gas Units)
which senses the temperature of the shortening. If the short-
ening
temperature
exceeds
425
°
F (218
°
C), this switch opens
and shuts off heat to the frypot. When the temperature of the
shortening drops to a safe operation limit, the control must be
manually reset by pressing the red reset button. The red reset
button is located under the control panel, in the front of the fryer.
(Figure 2-1). This allows heat to be supplied to the frypot.
Before replacing a high temperature limit control, check to see
that
its
circuit
is
closed.
Figure 2-1
The shortening temperature must be below 380
°
F (193
°
C)
to accurately perform this check.
Checkout
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1.
Remove
the
control
panel.
Figure
2-2.
Figure
2-2
1003
2-1
SECTION 2. MAINTENANCE
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Model OFE/OFG/OEA/OGA-341, 342 1-3. HIGH TEMPERATURE 2. Using a Phillip’s head screwdriver, remove the screws securing LIMIT CONTROL the inner heat shield and remove from unit. Figure 2-3. (Gas Units) (Continued) Figure 2-3 3. Remove the screw securing the high limit bracket to the frame and remove ...
Model OFE/OFG/OEA/OGA-341, 342 2-4. COMPLETE CONTROL Should the control board become inoperative, follow these PANEL REPLACEMENT instructions for replacing the board. 1. Remove electrical power supplied to the unit. To avoid electrical shock or property damage, move the power switch to OFF and disco...
Model OFE/OFG/OEA/OGA-341, 342 2-5. POWER SWITCH (Continued) 4. With control panel removed, and the wires off the switch, push in on tabs on the switch to remove from panel. Figure 2-12. 5. Replace with new switch, and reconnect wires to switch. 6. Replace the control panel. Figure 2-12 2-6. TEMPERA...