Henny Penny 342 - Manual

Henny Penny 342

Henny Penny 342 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
Page: / 30

Table of Contents:

  • Page 2 – Model OFE/OFG/OEA/OGA-341, 342; LIMIT CONTROL
  • Page 4 – When plugging connectors onto new control panel, be sure the
  • Page 5 – To avoid electrical shock or property damage, move the
  • Page 6 – Excess force will damage probe.
  • Page 8 – PILOT / IGNITOR
  • Page 11 – REPLACEMENT; To avoid property damage, do not tamper with, or disas semble
  • Page 14 – Figure; Figure; Using a 1-inch wrench, loosen the nut securing the main gas; Figure
  • Page 16 – Remove the wire cover from the blower motor housing.
  • Page 18 – Wire; Heating elements should never be energized without
  • Page 19 – Heat
  • Page 26 – MOTOR
  • Page 29 – Using 7/16” socket, remove the 4 nuts securing the support
  • Page 30 – Remove the 2 top screws securing the support plate and
Loading the manual

Model OFE/OFG/OEA/OGA-341, 342




2-1. INTRODUCTION

This section provides procedures for the check out and

replacement of the various parts used within the fryer. Before

replacing any parts refer to the Troubleshooting Section. It will aid

you in determining the cause of the malfunction.

2-2. MAINTENANCE HINTS

1. You may need to use a multimeter to check the electric

components.

2. When the manual refers to the circuit being closed, the

multimeter should read zero unless otherwise noted.


3. When the manual refers to the circuit being open, the

multimeter

will

read

infinity.

2-3. HIGH TEMPERATURE
LIMIT CONTROL

This high temperature control is a safety, manual reset control,

(Gas Units)

which senses the temperature of the shortening. If the short-

ening

temperature

exceeds

425

°

F (218

°

C), this switch opens

and shuts off heat to the frypot. When the temperature of the

shortening drops to a safe operation limit, the control must be

manually reset by pressing the red reset button. The red reset

button is located under the control panel, in the front of the fryer.

(Figure 2-1). This allows heat to be supplied to the frypot.


Before replacing a high temperature limit control, check to see

that

its

circuit

is

closed.

Figure 2-1

The shortening temperature must be below 380

°

F (193

°

C)

to accurately perform this check.

Checkout


To avoid electrical shock or property damage, move the

power switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.


1.

Remove

the

control

panel.

Figure

2-2.

Figure

2-2




1003

2-1

SECTION 2. MAINTENANCE

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Model OFE/OFG/OEA/OGA-341, 342; LIMIT CONTROL

Model OFE/OFG/OEA/OGA-341, 342 1-3. HIGH TEMPERATURE 2. Using a Phillip’s head screwdriver, remove the screws securing LIMIT CONTROL the inner heat shield and remove from unit. Figure 2-3. (Gas Units) (Continued) Figure 2-3 3. Remove the screw securing the high limit bracket to the frame and remove ...

Page 4 - When plugging connectors onto new control panel, be sure the

Model OFE/OFG/OEA/OGA-341, 342 2-4. COMPLETE CONTROL Should the control board become inoperative, follow these PANEL REPLACEMENT instructions for replacing the board. 1. Remove electrical power supplied to the unit. To avoid electrical shock or property damage, move the power switch to OFF and disco...

Page 5 - To avoid electrical shock or property damage, move the

Model OFE/OFG/OEA/OGA-341, 342 2-5. POWER SWITCH (Continued) 4. With control panel removed, and the wires off the switch, push in on tabs on the switch to remove from panel. Figure 2-12. 5. Replace with new switch, and reconnect wires to switch. 6. Replace the control panel. Figure 2-12 2-6. TEMPERA...

Other Henny Penny Models

All Henny Penny Other