Henny Penny OFE-341 - Manual
Henny Penny OFE-341 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 3 – Model OFE/OFG/OEA/OGA-341, 342
- Page 6 – REQUIREMENTS
- Page 7 – Refer to the table below for supply wiring and fusing.; Volts; CE units require a minimum wire size of 6mm to be wired to the
Model OFE/OFG/OEA/OGA-341, 342
2-1. INTRODUCTION
This section provides the installation instructions for the
Henny Penny open fryer.
Installation of the unit should be preformed only by a
qualified service technician.
Do not puncture the unit with any objects such as drills
or screws as component damage or electrical shock
could result.
2-2. UNPACKING
The Henny Penny open fryer has been tested, inspected,
and expertly packed to ensure arrival at its destination in
the best possible condition. The unit is banded to a wooden
skid and then packed inside a heavy cardboard carton with
sufficient padding to withstand normal shipping treatment.
Any shipping damage should be noted in the presence
of the delivery agent and signed prior to his or her
departure.
1.
Carefully cut bands from cardboard carton.
2.
Lift carton from fryer.
3. Cut and remove the metal bands holding the fryer to the
pallet.
4. Remove the fryer from the pallet.
Take care when moving the fryer to prevent
personal injury. Single-well fryers weigh 348lbs.
(158 kg) and 2-well fryers weigh 700 lbs. (318 kg).
2-1
903
SECTION 2. INSTALLATION
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Model OFE/OFG/OEA/OGA-341, 342 2-5. VENTILATION OF FRYER (Continued) When installing the gas fry station do not attach an extension to the gas flue exhaust stack. This may impair proper operation of the burner, causing malfunctions and possible negative back draft. 2-6. GAS SUPPLY The gas open fryer...
Model OFE/OFG/OEA/OGA-341, 342 2-7. GAS LEAK TEST Prior to turning the gas supply on, be sure the gas valve knob on the gas control valve is in the OFF position. Upon initial installation, and after moving the unit, the piping and fittings should be checked for gas leaks. A simple checking method is...
Model OFE/OFG/OEA/OGA-341, 342 2-9. ELECTRICAL REQUIREMENTS OFG/OGA-340 SERIES (Continued) To avoid electrical shock, do not disconnect the ground (earth) plug. This fryer must be adequately and safely grounded. Refer to local electrical codes for correct grounding (Earthing) proceduresor in absence...