Page 2 - Installation – Electric Units
CSLCSMCSB 63 Installation – Electric Units (continued) Floor Units: NOTE: Adequate clearance must be provided for servicing and for operation. Minimum clearances have to be maintained from the adjacent walls. Left Side Right Side Back Side CSB, CSM, CSL-20, 40 14” (350mm) 2” (50mm) 2” (50mm) Place t...
Page 3 - ELECTRICAL SUPPLY; Model; CHANGES IN VOLTAGE
CSLCSMCSB 64 ELECTRICAL SUPPLY Standard electrical supply for all Combi-Steamers is 208-240 volt, 3 phase, 50-60 Hz. NOTE: The power connections are located behind the service door (see section 5-3). Each unit requires a separate fused ser vice according to the following table: (3 phase only) Model ...
Page 4 - WATER SUPPLY; DRAIN CONNECTION
CSLCSMCSB 65 WATER SUPPLY The Combi-Steamer should only be connected to a cold water supply which meets the quality requirements by theEPA on drinking water. Soft water must be at least 5 or 6 grains. The recommended water supply pressure is 44 psi, but 22 to 87 psi will work. The water connection i...
Page 5 - CSG; INSTALLATION GAS UNITS; Installation – Gas Units
CSG 66 INSTALLATION GAS UNITS This section provides the installation instr uctions for the Henny Penny Gas Combi-Steamers NOTE: The installation must conform with local codes or in the absence of local codes, with ANSI Z223.1 latest edition and electrical code ANSI/NFPA No. 70 latest edition. NOTE: ...
Page 8 - ELECTRICAL SUPPLY-CSG
CSG 69 Installation – Gas Units (continued) ELECTRICAL SUPPLY-CSG The gas Combi-Steamer requires 120 volt, single phase, 60 Her tz, 15 amp, 3 wire grounded ser vice. The gas unitis factor y equipped with a grounded cord and plug. NOTE: The unit will not function and the reset signal will stay on wit...
Page 9 - RIGHT; CABLE RESTRAINT
CSG 70 GAS SUPPLY-CSG RIGHT MINIMUM PULL of equipment away from wall permissible for accessibility toQuick Disconnect Device WRONG AVOID SHARP BENDS AND KINKS whenpulling equipment away from wall. (Maximumpull will kink ends, even if installed properly,and reduce Connector life.) Couplings and hose ...
Page 10 - GAS SUPPLY
CSG 71 GAS SUPPLY (continued) A steam burner gas valve and dr y heat burner gas valve respectively are responsible for the gas supply to the indi-vidual burners. The Combi-Steamer models CSG have manual shut-of f valves, that can be reached from the frontwithout tools. The manual shut-of f valves of...