Henny Penny OE-100 - Manual

Henny Penny OE-100

Henny Penny OE-100 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
Page: / 22

Table of Contents:

  • Page 2 – Henny Penny; THERMAL SENSOR; NOTE
  • Page 3 – thermal sensor bulb straight out from pot fitting.
  • Page 5 – HEATING ELEMENTS
  • Page 6 – Replacement
  • Page 8 – FAN
  • Page 9 – Remove the four screws, washers, and nuts securing the fan to the; Checkout; With control panel removed and wires off the switch, push in on
  • Page 11 – SWITCH; Remove electrical power supplied to unit.
  • Page 12 – Open panel board and cut wires at the connectors which go to
  • Page 13 – Installation
  • Page 14 – REPAIR
  • Page 15 – To reassemble, place rotor on drive shaft, and place rollers into; If the pump needs to be replaced, loosen one inch nuts from the
  • Page 16 – REPLACEMENT
Loading the manual

2-1

Henny Penny

Model OE-100

SECTION 2. MAINTENANCE

2-1.

INTRODUCTION

This section provides procedures for checking and replacement of the
various parts used within the unit. Before replacing any parts, refer to
Section 1, Troubleshooting. It will aid you in determining the cause of a
particular malfunction.

2-2.

TEST INSTRUMENTS

You may use two test instruments to check the electric compo-
nents.

• A continuity light.

• An ohmmeter.

When the manual refers to the circuit being closed, the continuity
light will be illuminated or the ohmmeter should read zero (0)
unless otherwise noted.

When the manual refers to the circuit being open, the continuity
light will not illuminate or the ohmmeter will read one (1).

NOTE

A continuity light cannot be used to check coils or motors.

2-3.

REMOVING THE
CONTROL PANEL

To replace parts located inside the fryer, you will need to remove the
control panel. The following steps provide the correct procedure.

1. Place the power switch in the OFF position.

Disconnect the power cord from the wall receptacle or
power at the fuse or breaker box, or electrical shock could
result.

2. Remove the decorative strip, one located on each side of the

control panel, by removing the screw located on the bottom
of the decorative strip.

593

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Henny Penny; THERMAL SENSOR; NOTE

Henny Penny Model OE-100 2-2 2-4. THERMAL SENSOR The thermal sensor determines the shortening temperature. If a mal-function does occur, an E6 will be displayed on the digital readout.Turn unit to OFF position, then back to COOK position. If E6 is stilldisplayed, the thermal sensor must be replaced ...

Page 3 - thermal sensor bulb straight out from pot fitting.

2-3 Henny Penny Model OE-100 2-5. HIGH TEMPERATURELIMIT CONTROL The high temperature limit control is a manual reset control whichsenses the temperature of the shortening. If the shortening temperatureexceeds the safe operating limit, this control will open and shut off theheat to the frypot. The hi...

Page 5 - HEATING ELEMENTS

2-5 Henny Penny Model OE-100 2-6. HEATING ELEMENTS NOTE Heating elements are available for 208 and 480 voltage.Check the data plate to determine the correct voltage. If the shortening's temperature recovery is very slow or at aslower rate than required, this may indicate defective heatingelement(s)....

Other Henny Penny Models