Page 3 - Model OFE/OFG/OEA/OGA-341, 342

Model OFE/OFG/OEA/OGA-341, 342 2-5. VENTILATION OF FRYER (Continued) When installing the gas fry station do not attach an extension to the gas flue exhaust stack. This may impair proper operation of the burner, causing malfunctions and possible negative back draft. 2-6. GAS SUPPLY The gas open fryer...

Page 6 - REQUIREMENTS

Model OFE/OFG/OEA/OGA-341, 342 2-7. GAS LEAK TEST Prior to turning the gas supply on, be sure the gas valve knob on the gas control valve is in the OFF position. Upon initial installation, and after moving the unit, the piping and fittings should be checked for gas leaks. A simple checking method is...

Page 7 - Refer to the table below for supply wiring and fusing.; Volts; CE units require a minimum wire size of 6mm to be wired to the

Model OFE/OFG/OEA/OGA-341, 342 2-9. ELECTRICAL REQUIREMENTS OFG/OGA-340 SERIES (Continued) To avoid electrical shock, do not disconnect the ground (earth) plug. This fryer must be adequately and safely grounded. Refer to local electrical codes for correct grounding (Earthing) proceduresor in absence...