Page 3 - EN; RECOMMENDATIONS AND SUGGESTIONS; INSTALLATION
EN 3 3 RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this appliance. Accord- ingly, you may find descriptions of individual features that do not apply to your specific appliance. INSTALLATION • The manufacturer will not be held liable for any damages resulting...
Page 4 - CHARACTERISTICS; Dimensions
EN 4 4 CHARACTERISTICS Dimensions * ** * Dimensions of the hood in ducting version. ** Dimensions of the hood in recycling version.
Page 6 - Drilling the Wall and Fixing the Brackets
EN 6 6 INSTALLATION Drilling the Wall and Fixing the Brackets 7.2.1 11 12a X 116 1÷2 116 565 67 280 280 650 mm min 15 Draw the following on the Wall: • a Vertical line up to the ceiling or top surface, at the centre of the area in which the Hood is to be fitted; • a Horizontal line: 650 mm min. abov...
Page 7 - Hood body installation; Connections; DUCTED VERSION AIR EXHAUST SYSTEM
EN 7 7 Hood body installation • Before hooking the hood body it is necessary to tighten 2 Vr screws placed in the fixing points of the body. • Hook the hood body on the 12a screws. • Tighten completely 12a support screws. • The correct hood body position can be levelled with Vr screws. • Fix the hoo...
Page 8 - ELECTRICAL CONNECTION; Fitting the Chimney; Upper chimney
EN 8 8 ELECTRICAL CONNECTION • Connect the hood to the mains through a two-pole switch hav- ing a contact gap of at least 3 mm. • Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan...
Page 9 - USE; Control board
EN 9 9 USE A B C D E F G H Control board Key Function Display A Switches the extractor motor on and off at the latest selected speed Indicates the selected speed. B Decreases the suction speed. C Increases the suction speed. D By pressing this key it is possible to activate the intensive speed from ...
Page 10 - MAINTENANCE; Cleaning the Comfort Panels; • Clean the inside as well by using a damp cloth and neutral de-
EN 1 10 MAINTENANCE REMOTE CONTROL (OPTIONAL) The appliance can be controlled using a remote control powered by a 1.5 V carbon-zinc alkaline batteries of the standard LR03-AAA type (not included). • Do not place the remote control near to heat sources. • Used batteries must be disposed of in the pro...
Page 11 - Metal grease filters; Alarm reset
EN 1 11 Metal grease filters The Filters can be washed in the dishwashing. They need to be washed when FF- sign appears on the display or in any case every 2 months, or even more frequently in case of particularly inten- sive use of the hood. Alarm reset • Switch off the hood and the lights. If the ...
Page 12 - REPLACING THE CHARCOAL FILTER
EN 1 12 Charcoal filter (recycling version) • This filter cannot be washed or regenerated. It must be replaced when the EF appears on the display or at least once every 4 months. Activation of the alarm signal • In the recycling version hoods the filter saturation alarm must be activated during the ...
Page 13 - Lighting unit; REPLACING OF THE LED UNIT
EN 1 13 Lighting unit REPLACING OF THE LED UNIT LED • To remove the lighting unit a screwdriver can be used in order to slightly press the side part of the unit. • Remove the unit, remove the electrical connector and replace the unit with a new one. ("To purchase contact technical support") ...