Page 2 - LIMITED WARRANTY AND LIMITATION OF LIABILITY; Fluke Corporation
LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for three years from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal ...
Page 3 - Table of Contents; Title Page
i Table of Contents Title Page Introduction .................................................................................................................... 1 How to Contact Fluke ..................................................................................................... 1 Safety Infor...
Page 5 - Introduction; Warning; How to Contact Fluke; To register your product, visit; Safety Information; The Product complies with:; Edition; Edition
1 Introduction Warning To prevent possible electrical shock, fire, or personal injury, read all safety information before you use the Product. The 3000 FC Wireless Multimeter (the Product) is a True-rms Digital Multimeter. How to Contact Fluke To contact Fluke, call one of the following telephone...
Page 6 - Users Manual; identifies conditions and procedures that are; Caution; identifies conditions
3000 FC Users Manual 2 A Warning identifies conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that can cause damage to the Product or the equipment under test. A list of symbols used on the Product and in this manual is in Table 1. Warning To...
Page 8 - Symbol Description Symbol
3000 FC Users Manual 4 Table 1. Symbols Symbol Description Symbol Description WARNING. RISK OF DANGER. WARNING. HAZARDOUS VOLTAGE. Risk of electric shock. Consult user documentation. Minimum fuse interrupt rating. Conforms to European Union directives. Conforms to relevant Australian Sa...
Page 9 - Hazardous Voltage; Note
Wireless Multimeter Hazardous Voltage 5 Hazardous Voltage The hazardous voltage warning shows on the display when the Product detects a voltage ≥ 30 V. Test Lead Alert The display shows LEAD for 1 second when you turn the function switch to or from the mA position to remind you to make sure the te...
Page 10 - MIN MAX AVG Record Mode
3000 FC Users Manual 6 MIN MAX AVG Record Mode The MIN MAX AVG record mode records the minimum and maximum input values, and calculates a running average of all measurements. The Product beeps when a new high or low is sensed. Note For dc functions, accuracy is the specified accuracy of the measurem...
Page 11 - Display Hold; Yellow Button
Wireless Multimeter Display Hold 7 Display Hold Warning To prevent possible electrical shock, fire, or personal injury, do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured. In the display hold mode,...
Page 12 - Manual and Auto Range; Auto; Option
3000 FC Users Manual 8 Manual and Auto Range The Product can be set to manual or auto range. In autorange, the Product sets the range so the input is shown with the best resolution. Manual range lets you set the range. When you turn on the Product, it is set to autorange and Auto shows on the displa...
Page 13 - Features; Terminal Description; mA
Wireless Multimeter Features 9 Features Tables 3 through 5 are lists of Product features with descriptions. Table 3. Inputs 3 1 2 gxr001.eps Terminal Description mA - Input for 3.00 mA to 400.0 mA current measurements and current frequency. COM - Return terminal for all measurements. - Input...
Page 14 - Table 4. Rotary Switch Positions
3000 FC Users Manual 10 Table 4. Rotary Switch Positions Switch Position Function DC voltage from 1 mV to 1000 V. Push to measure frequency from 2 Hz to 99.99 kHz. AC voltage measurement from 60.0 mV to 1000 V. Push to measure frequency from 2 Hz to 99.99 kHz. Push again to measure Volts/Hertz. DC v...
Page 15 - Table 5. Pushbuttons
Wireless Multimeter Features 11 Table 5. Pushbuttons Button Switch Position Function Selects frequency. Selects frequency. Selects ac millivolts. [1] Selects capacitance. Selects diode test. Push once to select dc milliamps. Push twice to select ac frequency. [1] All positions Sets the Product to ...
Page 16 - Button; All positions
3000 FC Users Manual 12 Table 5. Pushbuttons (cont.) Button Switch Position Function Not related to switch position Push once to turn on the backlight and push again to turn off the backlight. The backlight turns off automatically after 2 minutes. All positions Starts the MIN MAX record function...
Page 17 - App; VDC
Wireless Multimeter AC Zero Input Behavior of True-rms Meters 13 AC Zero Input Behavior of True-rms Meters Average responding meters can accurately measure only pure sinewaves. A True-rms meter can accurately measure distorted waveform signals. A minimum input voltage is necessary for calculating Tr...
Page 18 - Pair with Wireless Test Tools
3000 FC Users Manual 14 Pair with Fluke Connect App When the Product radio is set to the App (send) mode, you can use the Fluke Connect app on a mobile device to view, save, and share measurements. To pair with the Fluke Connect app: 1. Turn on the Product (the radio is off at the initial power on)....
Page 19 - Tools
Wireless Multimeter Wireless Radio Setup 15 To start the discovery procedure: 1. Push to highlight the Tools (receive) option. 2. Push to enable the Tools selection and start the discovery procedure. When the discovery procedure starts: • the icon shows on the display • the button blinks at ...
Page 21 - Basic Measurements; AC and DC Voltage Measurements
Wireless Multimeter Basic Measurements 17 Disconnect the Wireless Radio You can use any one of these methods to disconnect a test tool radio from the Product. • Turn off the test tool. • Push on the test tool to turn off the radio in the test tool. The test tool remains turned on to continue measu...
Page 22 - Volts AC; Figure 1. AC and DC Voltage Measurements
3000 FC Users Manual 18 Volts AC Volts DC Millivolts DC gxr002.eps Figure 1. AC and DC Voltage Measurements
Page 23 - OL; in
Wireless Multimeter Basic Measurements 19 Volts/Hertz Ratio The Product can show the ratio of volts to frequency of an ac signal. Set the Product as shown in Figure 2 to show Volts/Hertz ratio. When the Product is set to the Volts/Hz function, the voltage range is set to manual. If the voltage incre...
Page 24 - The resistance ranges are 600.0; Figure 3. Resistance Measurements
3000 FC Users Manual 20 Resistance Measurements Warning To prevent possible electrical shock, fire, or personal injury, disconnect power and discharge all high-voltage capacitors before you measure resistance, continuity, capacitance, or a diode junction. The Product sends a small current through...
Page 25 - Product as shown in Figure 4.; Figure 4. Capacitance Measurements
Wireless Multimeter Basic Measurements 21 Capacitance Measurements Warning To prevent possible electrical shock, fire, or personal injury, disconnect power and discharge all high-voltage capacitors before you measure resistance, continuity, capacitance, or a diode junction. Capacitance ranges are...
Page 27 - to toggle the Product between
Wireless Multimeter Basic Measurements 23 AC or DC Current Measurements Warning To prevent possible electrical shock, fire, or personal injury: • Remove circuit power before you connect the Product in the circuit when you measure current. Connect the Product in series with the circuit. • Limit op...
Page 28 - DC
3000 FC Users Manual 24 DC gxr007.eps Figure 6. AC and DC Current Measurements
Page 29 - or a short circuit. The display shows; if the diode is
Wireless Multimeter Basic Measurements 25 Diode Test Warning To prevent possible electrical shock, fire, or personal injury, disconnect power and discharge all high-voltage capacitors before you measure resistance, continuity, capacitance, or a diode junction Do a diode test on diodes, transistor...
Page 30 - BEEP
3000 FC Users Manual 26 Good Diode Bad Diode Bad Diode Good Diode Reverse Bias 1 BEEP OPEN and Shorted Forward Bias gxr006.eps Figure 7. Diode Test
Page 31 - Hints for frequency measurements:
Wireless Multimeter Basic Measurements 27 Frequency Measurement A frequency measurement is a count of the number of times an ac voltage or current signal passes through a threshold point each second. The Product autoranges to one of four frequency ranges: 99.99 Hz, 999.9 Hz, 9.999 kHz, and 99.99 kHz...
Page 32 - Hz; Figure 8. Frequency Measurement
3000 FC Users Manual 28 Hz x 2 Hz AC/DC Voltage Frequency AC Current Frequency gxr008.eps Figure 8. Frequency Measurement
Page 33 - Maintenance; General Maintenance; Fuse Test
Wireless Multimeter Maintenance 29 Maintenance Warning To prevent a possible electrical shock or personal injury: • Have an approved technician repair the Meter. • Do not operate the Product with covers removed or the case open. Hazardous voltage exposure is possible. • Use only specified replace...
Page 34 - Battery and Fuse Replacement
3000 FC Users Manual 30 440 mA <12 OK OK gxr009.eps Figure 9. Fuse Test Battery and Fuse Replacement Warning To prevent possible electrical shock, fire, or personal injury: • Replace a blown fuse with exact replacement only for continued protection against arc flash. • Use only specified repla...
Page 36 - Figure 10. Battery and Fuse Replacement
3000 FC Users Manual 32 gxr010.eps Figure 10. Battery and Fuse Replacement
Page 37 - Service and Parts; How to Contact; Table 6. Replaceable Parts
Wireless Multimeter Service and Parts 33 Service and Parts If the Product fails, replace the batteries and do a fuse test. Replacement parts and accessories are shown in Table 6 and Figure 11. To get parts and accessories, refer to the How to Contact Fluke section. Table 6. Replaceable Parts Descrip...
Page 38 - Figure 11. Replacement Parts
3000 FC Users Manual 34 Battery AA x 1.5 V Battery Door TL175 Test Lead Set AC175 Threaded Alligator Clips 3000 FC Quick Reference Guide 3000 FC Safety Information Fuse 440 mA 1000 V, Fast gxr012.eps Figure 11. Replacement Parts
Page 39 - Table 7. Accessories
Wireless Multimeter Service and Parts 35 Table 7. Accessories Item Description TPAK ToolPak Magnetic Hanger FLK-A3000 FC a3000 FC Wireless AC Clamp – Measure ac current to 400 amps FLK-A3001 FC a3001 FC Wireless iFlex – Measures ac current to 2500 amps FLK-A3002 FC a3002 FC Wireless AC/DC Clamp – Me...
Page 40 - Specifications
3000 FC Users Manual 36 Specifications Maximum voltage between any Terminal and Earth Ground ................................. 1000 V Frequency Overload Protection .......................... ≤ 10 7 V-Hz Fuse Protection for mA inputs ....................... 0.44 A, 1000 V, IR 10 kA Display Update r...
Page 42 - For all specifications:; AC Voltage
3000 FC Users Manual 38 For all specifications: Accuracy is specified for 1 year after calibration, at operating temperatures of 18 ° C to 28 ° C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]). AC Voltage...
Page 44 - Frequency
3000 FC Users Manual 40 AC and DC Current Function Range [1] Resolution Accuracy (45 Hz to 1 kHz) 60.00 mA 0.01 mA 1.5 % + 3 400.0 mA [3] 0.1 mA [2] 60.00 mA 0.01 mA 0.5 % + 3 400.0 mA [3] 0.1 mA [1] All ac current ranges are specified from 5 % of range to 100 % of range. [2] Input burden voltag...