Page 2 - LIMITED WARRANTY AND LIMITATION OF LIABILITY
LIMITED WARRANTY AND LIMITATION OF LIABILITY Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is two years and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 days. This war...
Page 3 - Table of Contents; Title; Setting IR Fusion
i Table of Contents Title Page Introduction ............................................................................... 1 Contacting Fluke ....................................................................... 1 Safety Information ...................................................................
Page 4 - ii
Ti10, Ti25, TiR and TiR1 Users Manual ii Changing the SD Card ............................................................... 15 Setting the Backlight .................................................................. 15 General Specifications ...........................................................
Page 5 - iii; List of Tables; Table Title; List of Figures; Figure
iii List of Tables Table Title Page 1. Symbols ..................................................................................... 2 2. Features and Controls ................................................................ 4 List of Figures Figure Title Page 1. Range and Span Settings ...............
Page 6 - iv
Page 7 - Or, visit Fluke’s Web site at
1 Introduction The Fluke Ti10, Ti25, TiR, and TiR1 Thermal Imagers (hereafter “the Imager”) are handheld imaging cameras used for predictive maintenance, equipment troubleshooting, and verification. All four Imagers produce thermal and visual images on a 640 X 480 display. Thermal and visual images ...
Page 8 - Safety Information; A Warning; identifies hazardous conditions and actions that could cause; Warning; Symbol Description Symbol
Ti10, Ti25, TiR and TiR1 Users Manual 2 Safety Information Use the Imager only as specified in this manual. See Table 1 for a list of symbols used on the Imager and in this manual. A Warning identifies hazardous conditions and actions that could cause bodily harm or death. A Caution identifies condi...
Page 9 - Unpacking the Imager
Thermal Imagers Unpacking the Imager 3 Unpacking the Imager Carefully unpack the following items: • Ti10, Ti25, TiR or TiR1 Imager • AC Power Adapter/Charger • Rugged Carrying Case • SD Memory Card • SD Card Reader • Soft Transport Bag • User Manuals (in various languages) • SmartView™ Software • Wa...
Page 11 - Item Description; Using the Menu; Language; Setting the Imager Clock
Thermal Imagers Using the Menu 5 Table 2. Features and Controls (cont.) Item Description 9 SD memory card compartment 10 Retractable Lens Cover 11 Visual camera 12 Thermal (IR) camera 13 Focus control 14 Trigger Using the Menu The menus, coupled with the three softkeys ( c , a , and d ), provide acc...
Page 12 - Focusing and Capturing an Image
Ti10, Ti25, TiR and TiR1 Users Manual 6 Setting the Date To set the date: 1. Press a until Date appears over the F1 softkey. 2. Press the softkey labeled Date . The date can be displayed in one of two formats: MM/DD/YY or DD/MM/YY . 3. Press the softkey labeled with the desired date format. 4. Press...
Page 13 - Note; Settings; allows modification of image; Saving Imager Data; Press the softkey labeled; Store; . If the SD card is in the Imager and there; Adjusting the Thermal Image
Thermal Imagers Saving Imager Data 7 Note Minimum focus distance for thermal (IR) camera is 15 cm (approx. 6 inches). Minimum focus distance for visible (visual) light camera is 46 cm (approx. 18 inches). Note The Imager can save the image as a simple picture or as a radiometric image that allows fu...
Page 15 - Figure 1. Range and Span Settings; Level
Thermal Imagers Adjusting the Thermal Image 9 Total Imager Range Span Le v el exj02.eps Figure 1. Range and Span Settings Setting the Level (Manual) When put into manual ranging, the level setting adjusts the thermal span within the total temperature range of the Imager. See Figure 1. To set the lev...
Page 16 - Reviewing and Deleting Stored Images
Ti10, Ti25, TiR and TiR1 Users Manual 10 2. Press the softkey labeled Increase to widen the temperature span or Decrease to narrow it. 3. Press the softkey labeled Done to set the Imager’s range level. Switching Between PIP and Full IR (Ti10 and TiR Only) The Imager can be set to display a full infr...
Page 19 - Emissivity
Thermal Imagers Setting Emissivity (Ti25 and TiR1 only) 13 the object's surface. The Imager detects the infrared energy from an object and uses this information to estimate the temperature of the object. Most of the objects measured such as painted metal, wood, water, skin, and cloth are very effici...
Page 20 - Setting File Format; File Format; SmartViewTM Software
Ti10, Ti25, TiR and TiR1 Users Manual 14 To set the emissivity value directly: 1. Press the softkey labeled ε . 2. Press the softkey labeled Up or Down to increment or decrement respectively the emissivity value displayed just above the softkey labels. 3. Press the softkey labeled Done to select the...
Page 21 - Changing the SD Card; Setting the Backlight; Backlight; General Specifications
Thermal Imagers Changing the SD Card 15 Changing the SD Card To eject an SD card from the Imager, press in on the exposed edge of the SD card and then release. The card should pop partially out after releasing it. Carefully pull the card out of the slot. Note The SD Card can be inserted and removed ...
Page 23 - Detailed Specifications
Thermal Imagers Detailed Specifications 17 Detailed Specifications Temperature Measurements Temperature Range (not calibrated below -10 ° C) TiR and TiR1 ................................................. -20 ° C to +100 ° C Ti10 ............................................................... -20 ° C...