Page 2 - CAUTION; Read and understand this manual before using this PC-HACCP Kit.; Photo 2; PC–HACCP KIT CONTENTS; Photo 1
2 1 Software-CD - 300550 2 Network Connection Cable – 300551 (included only w/ 232 kit) 3 Dongle - C5009210 4 PC Interface Converter - C5009156 (included only w/ 232 kit) 5 9 Volt Power Supply for Converter – 300548 (included only w/ 232 kit) 6 Operating Instructions – 260AZV 1 4 2 3 5 CAUTION Read ...
Page 3 - PHOTO 3
3 1 Electronic Board (1) – C5019104 2 Connector (1) – C5002091 3 Bracket with Studs (1) – C2114799 4 Control Panel Spacers (2) – C8009030 5 Screws – M3 (2) - 111633 6 Lock Washers (2) – C8016001 7 Hexagon Nuts – M3 (4) – C8004012 PHOTO 3 RS485 Communication Module p/n C-RS485 1 4,7 2 3 5, 6, 7 5, 6,...
Page 4 - TO CONNECT THE RS232 CONVERTER TO THE PC; Photo 4
4 TO CONNECT THE RS232 CONVERTER TO THE PC Photos 4, 5, and 6 show the correct cable connections from the PC to the PC Converter for RS232. Note the position of the Dongle on the PC in Photo 5. Make sure the PC Converter is connected to the 9-volt DC power supply as shown in Photo 7. Photo 4 Photo 5...
Page 5 - RS232 CABLE CONNECTION FOR CONVERTER TO RS485 ONLY; Photo 8 shows the cable connections for the PC Converter.; Photo 8
5 NOTE: A: RED WIRE B: BLACK WIRE GROUND: GROUND OR SHIELD WIRE RS232 CABLE CONNECTION FOR CONVERTER TO RS485 ONLY Photo 8 shows the cable connections for the PC Converter. The PC Converter wiring is connected to the FIRST Combi in the Chain. Photo 8
Page 7 - Remove the Control Side Cover; From the bottom edge of the side panel, push up and pull out.
7 Remove the Control Side Cover Turn the 1/4 turn quick-locks to loosen. From the bottom edge of the side panel, push up and pull out. Remove the side panel and set it aside. Photo 13 Photo 16 Photo 15 Photo 14
Page 8 - Remove the Control Panel; Remove the Control Panel and place it on a work surface as shown.
8 Remove the Control Panel Photo 17 Press down and turn counterclockwise to remove the Operation Panel retention screw. Photo 18 Remove the Operation Panel out from the rear. Be careful not to drop it. Disconnect the computer cable from the Operation Panel and set the panel aside. Photo 19 Remove th...
Page 9 - Attaching the Base Plate to the Communication Module
9 Attaching the Base Plate to the Communication Module 1. Mount the board to the panel using the spacers, nuts and washers included in the kit. Photo 20 Photo 21 Press the Communication Module Interface onto the Control Module. Tighten the screws holding the Communication Module to the Control Modul...
Page 11 - Inserting the Communication Module Cable into the Oven; Remove the sanitary seal plug from the underside of the Combi.
11 Inserting the Communication Module Cable into the Oven Photo 30 Remove the sanitary seal plug from the underside of the Combi. Photo 31 Insert the new bushing, P/N 111751 into the opening. Pull the Communication Module cable through the Bushing. Pull enough wire through the bottom of the oven to ...
Page 12 - Connect the Network Cable to the Communication Module; : Attach the wire to the Converter at connection “A” and attach the; USB; Ground
12 Photo 25 Photo 26 Connect the Network Cable to the Communication Module Take care to match the wire ends or colors to the connections throughout the network to avoid miswiring. For RS232 Converter : Attach the wire to the Converter at connection “A” and attach the other end to connection “A” on t...
Page 13 - Setting the Jumpers on the Communication Module; Jumper setting for the first Combi and all Combis in the Network.
13 Setting the Jumpers on the Communication Module Photo 27 Jumper setting for the first Combi and all Combis in the Network. To set the jumpers: gently pull them from the board and install them as shown. Photo 28 Wire Connection and jumpers positions for last communication module in the Network. Ph...
Page 15 - Replace the Operation Panel; Remount the Operation Panel back into the Combi.
15 Replace the Operation Panel Photo 36 Remount the Operation Panel back into the Combi. Photo 37 Press down and turn clockwise to tighten the Operation Panel retention screw.
Page 16 - Replace the Control Side Panel; Photo; Push up and in from the bottom edge of the side panel.
16 Replace the Control Side Panel Photo 38 Photo 39 Push up and in from the bottom edge of the side panel. Photo 40 Photo 41 Turn the 1/4 turn quick-locks to tighten. See the PC-HACCP Instructions to use the PC-HACCP Network.
Page 17 - Directions for Installing the USB Adapter; the back of your computer.
17 Directions for Installing the USB Adapter 1. Plug the USB connector into the adapter and connect to one of the USB ports on the back of your computer. 2. Install the USB drivers onto your computer using the CD provided in the kit. 3. Follow the instructions that are on the CD to configure the COM...
Page 28 - Switches 1 and 4 are ON
28 For USB to RS485 Switches 1 and 4 are ON For USB to RS232 Switches 2, 3, 4 are ON 6. Once the computer recognizes the USB adapter, the dip switches in the adapter have to be set up for RS485 or RS232 data transfer; chose the correct setting to match the configuration you are using.
Page 30 - Cleveland Range, LLC; Revision Index Page; REV; REVISION HISTORY; DATE BY; ERB
260AZH REV. B Rev Page 116 March 2006 This Page for Internal Record Only, Not for Printing Cleveland Range, LLC 1333 East 179 th St, Cleveland, Ohio 44110 Drawing No. 260AZH Revision Index Page REV REVISION HISTORY DATE BY A 260AZH Production Release Per EO # C-6947 12-12-05 ERB B Added new part num...