Page 2 - SpecificationS; Save this Manual; general Safety ruleS; read and underStand all inStructionS; work area; keep your work area clean and well lit.; Cluttered benches and dark areas invite; keep children and visitors away while operating this tool.; Distractions can
Page 2 SKU 96375 for technical questions, please call 1-800-444-3353. SpecificationS Construction Formed/Stamped Steel Plate & Sheet High Impact Thermoplastic UnitSteel Bar Rubber/Thermoplastic GripCopper Wiring Finish Black Thermoplastic & Rubber Coating Overall Dimensions Station: 6-3/4” L...
Page 3 - electrical Safety; do not expose power tools to rain or wet conditions.; perSonal Safety; do not overreach. keep proper balance at all times.
Page 3 SKU 96375 for technical questions, please call 1-800-444-3353. electrical Safety grounded tools must be plugged into an outlet properly installed and grounded in accordance with all codes and ordinances. never remove the grounding prong or modify the plug in any way. do not use any adapter pl...
Page 4 - tool uSe and care; do not force the tool. use the correct tool for your application.; SerVice; section of this manual.; Specific Safety ruleS; Maintain labels and nameplates on the tool.
Page 4 SKU 96375 for technical questions, please call 1-800-444-3353. tool uSe and care use clamps (not included) or other practical ways to secure and support the workpiece to a stable platform. Holding the work by hand or against your body is unstable and may lead to loss of control. do not force ...
Page 5 - always keep the extension cord away from heated parts of the tool.; et seq; grounding; grounded toolS: toolS witH tHree prong plugS
Page 5 SKU 96375 for technical questions, please call 1-800-444-3353. always keep the extension cord away from heated parts of the tool. never leave the tool unattended when it is plugged into an electrical outlet. Turn off the tool, and unplug it from its electrical outlet before leaving. use cauti...
Page 6 - -prong plug and outlet; extenSion cordS; peres and use the sum to determine the required minimum cord size.
Page 6 SKU 96375 for technical questions, please call 1-800-444-3353. Your tool must be plugged into an appropriate outlet, properly installed and grounded in accordance with all codes and ordinances. The plug and outlet should look like those in the following illustration. (See 3-prong plug and out...
Page 7 - recoMMended MiniMuM wire gauge for extenSion cordS*; naMeplate; table a; SyMbology; unpacking; the Assembly Diagram near the end of this manual.
Page 7 SKU 96375 for technical questions, please call 1-800-444-3353. recoMMended MiniMuM wire gauge for extenSion cordS* (120 or 240 Volt) naMeplate aMpereS (at full load) extenSion cord lengtH 25 feet 50 feet 75 feet 100 feet 150 feet 0 – 2.0 18 18 18 18 16 2.1 – 3.4 18 18 18 16 14 3.5 – 5.0 18 18...
Page 8 - operation inStructionS; preparing the metal to be soldered
Page 8 SKU 96375 for technical questions, please call 1-800-444-3353. warning! Make sure the Power Switch (8) of the Soldering Station is in the “OFF” position and that the tool is unplugged from an electrical outlet before making any adjustments to the tool. Match up holes in Soldering Cord Sleeve ...
Page 9 - not; to the Soldering Tip.; Soldering tips
Page 9 SKU 96375 for technical questions, please call 1-800-444-3353. If other metals are to be soldered, thoroughly clean and scrape the metal surfaces. It may be necessary to apply acid flux (not included) to clean the metal surfaces before soldering. note: If soldering on printed circuit boards, ...
Page 10 - Some solders contain lead and some do not. Be extremely; replacing the Soldering tip; Make sure the Power Switch of the tool is in its “OFF” position and
Page 10 SKU 96375 for technical questions, please call 1-800-444-3353. solder will follow the heat. This technique is helpful when soldering joints, such as a tube in a coupling. By applying solder to the edge of the coupling and then mov-ing the soldering tip away from the edge, solder can be dragg...
Page 11 - do not use damaged equipment.; pleaSe read tHe following carefully
Page 11 SKU 96375 for technical questions, please call 1-800-444-3353. aged electrical wiring, and any other condition that may affect its safe operation. If abnormal noise or vibration occurs, have the problem corrected before further use. do not use damaged equipment. The tip should be cleaned per...
Page 12 - partS liSt and aSSeMbly diagraM; part; record; individually as replacement parts.
Page 12 SKU 96375 for technical questions, please call 1-800-444-3353. partS liSt and aSSeMbly diagraM part description Qty 1 Shell 1 2 Base 1 3 Panel 1 4 Transformer 1 5 Temperature Dial 1 6 Rubber Plug 1 7 Soldering Cord Connection 1 8 Power Switch 1 9 Screw PT4x2 4 10 PCB Board 1 11 Power Wire 1 ...