Page 3 - What is Included; Text Conventions; Convention; Icons
Intimidator™ Scan LED 200 User Manual (Rev. 02a) Page 3 of 22 1. B EFORE YOU B EGIN What is Included • 1 x Intimidator™ Scan LED 200 • 1 x Mounting bracket kit • 1 x Power Cord • 1 x Warranty Card • 1 x User Manual Unpacking Instructions Immediately upon receiving this product, carefully unpack it a...
Page 5 - NTRODUCTION; Product Overview; Power Out; Microphone
Intimidator™ Scan LED 200 User Manual (Rev. 02a) Page 5 of 22 2. I NTRODUCTION Product Overview Power Out DMX In DMX Out Power In Microphone Fuseholder
Page 6 - Product Dimensions
Page 6 of 22 Intimidator™ Scan LED 200 User Manual (Rev. 02a) Product Dimensions
Page 7 - ETUP; AC Power; Fuse Replacement
Intimidator™ Scan LED 200 User Manual (Rev. 02a) Page 7 of 22 3. S ETUP AC Power This product has an auto-ranging power supply and it can work with an input voltage range of 100~240 VAC, 50/60 Hz. To determine the power requirements for a particular fixture, see the label affixed to the back plate o...
Page 8 - Power Linking; You can power link up to 8 IntimidatorTM Scan LED 200 units on 120 VAC.
Page 8 of 22 Intimidator™ Scan LED 200 User Manual (Rev. 02a) Power Linking This fixture provides power linking via the Edison outlet located in the bottom of the unit. Please see the diagram below for further explanation. Power Linking Diagram You can power link up to 8 Intimidator™ Scan LED 200 un...
Page 9 - Mounting; Orientation; Mounting Diagram; Bracket
Intimidator™ Scan LED 200 User Manual (Rev. 02a) Page 9 of 22 Mounting Orientation The Intimidator™ Scan LED 200 may be mounted in any position, provided there is adequate room for ventilation around it. Rigging Before deciding on a location for this product, always make sure that it will be easy to...
Page 10 - PERATION; Control Panel Operation
Page 10 of 22 Intimidator™ Scan LED 200 User Manual (Rev. 02a) 4. O PERATION Control Panel Operation To access the control panel functions, use the four buttons located underneath the display. Button Function <MODE/ESC> Press to find an operation mode or to back out of the current menu option ...
Page 11 - DMX Operation; Starting Address; Only connect 32 fixtures to a single DMX daisy chain!
Intimidator™ Scan LED 200 User Manual (Rev. 02a) Page 11 of 22 DMX Operation Set this product in DMX mode to control it with a DMX controller. 1) Connect this product to a suitable power outlet. 2) Turn this product on. 3) Connect a DMX cable from the DMX output of the DMX controller to the DMX inpu...
Page 12 - Standalone Operation; SLAu
Page 12 of 22 Intimidator™ Scan LED 200 User Manual (Rev. 02a) Standalone Operation Master/Slave Mode (Sound-Active, Auto Mode) This mode allows a single unit, the master, to operate in one of the standalone modes, while one or more fixtures, slaves, synchronize their responses to the master. Master...
Page 13 - Service Mode; Hidden Menu Map
Intimidator™ Scan LED 200 User Manual (Rev. 02a) Page 13 of 22 Service Mode Hidden Menu Map This fixture has a hidden menu. The purpose of this menu is to adjust the home position (electronic adjustment) of the attributes listed below. Main Function Selection Instruction P128 000~255 Adjustment f or...
Page 14 - DMX Channel Assignments and Values; Channel
Page 14 of 22 Intimidator™ Scan LED 200 User Manual (Rev. 02a) DMX Channel Assignments and Values 8-Channel Mode \ Channel Function Value Setting 1 Pan 000 ó 255 0°~180° 2 Tilt 000 ó 255 0°~90° 3 Color 000 ó 007 008 ó 015 016 ó 023 024 ó 031 032 ó 039 040 ó 047 048 ó 055 056 ó 063 064 ó 071 072 ó 07...
Page 17 - General Maintenance; Always dry the mirror and lens carefully after cleaning them.
Intimidator™ Scan LED 200 User Manual (Rev. 02a) Page 17 of 22 5. T ECHNICAL I NFORMATION General Maintenance Dust build up reduces light output performance and can cause overheating. This can lead to reduction of the light source’s life or mechanical wear. To maintain optimum performance and minimi...
Page 18 - General Troubleshooting
Page 18 of 22 Intimidator™ Scan LED 200 User Manual (Rev. 02a) General Troubleshooting Symptom Possible Cause Possible Action Circuit breaker or fuse keeps blowing • Excessive load on the circuit • Make sure that the total load does not exceed 80% of the breaker or fuse nominal current • Short circu...
Page 19 - Returns Procedure
Intimidator™ Scan LED 200 User Manual (Rev. 02a) Page 19 of 22 Returns Procedure The user must send the merchandise prepaid, in the original box, and with its original packing and accessories. CHAUVET® will not issue call tags. Call CHAUVET® and request a Return Merchandise Authorization (RMA) numbe...
Page 20 - DMX Primer; DMX
Page 20 of 22 Intimidator™ Scan LED 200 User Manual (Rev. 02a) DMX Primer The USITT DMX512-A data transmission protocol (DMX, from now on) is based on the EIA-485 standard and it has 512 channels (001 to 512). This system requires a controller (DMX controller), one or more DMX compatible fixtures, a...
Page 21 - DMX Cabling; DMX Connectors
Intimidator™ Scan LED 200 User Manual (Rev. 02a) Page 21 of 22 DMX Cabling The DMX protocol requires using special data cables to accommodate for the high speed digital signals it uses. Despite their apparent similarities, data cables are electrically different from standard microphone cables becaus...