Page 2 - CONTENTS; I. INSTALLATION INSTRUCTIONS; IMPORTANT FOR FUTURE REFERENCE; Model Number Serial Number Date Purchased

2 CONTENTS I. INSTALLATION INSTRUCTIONS SECTION ITEM PAGE 1 General Description 3 2 Installation 3 3 Clearances 3 4 Gas Connection 3 5 Burners 4 6 Radiants 4 7 Top Grates 5 8 Lighting 5 9 Griddle Plates 5 10 Additional Installation Requirements 5 11 Installation with Casters 5 12 Optional Smoker Box...

Page 3 - BE SURE TO CAP WHICHEVER SIDE IS NOT CONNECTED.; ACCEPTABLE CLEARANCES:; Series XX; I MASSACHUSETTS; All gas products must be installed by a “Massachusetts” licensed; MINIMUM CLEARANCE FROM NON-COMBUSTIBLE CONSTRUCTION

4. GAS CONNECTION: The gas pressure regulator supplied must be installed at the gas inlet of each broiler. Each regulator is adjusted to yield a manifold pressure of 5 in. water column for natural gas or 10 in. water column for propane gas. No pressure regulator is required for propane gas in Canada...

Page 4 - FIGURE 1 Typical Ceramic Briquette Installation

The broiler and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psig (3.45 kPa). The broiler must be isolated from the gas supply piping system by closing its individual manual shutoff val...