Page 2 - DAMAGE. • DO NOT ADJUST THE PRE-CHARGE PRESSURE; RELIEF VALVE REQUIRED. A relief valve; GENERAL SAFETY INFORMATION
1. TABLE OF CONTENTS GENERAL SAFETY INFORMATION ........................................................... 2 COMPONENTS ........................................................................................... 3 INSTALLATION AND SIZING CONSIDERATIONS ..................................... 4 INSTAL...
Page 4 - INSTALLATION AND SIZING CONSIDERATIONS; SELECTION FOR CONSTANT PRESSURE; SELECTION FOR STANDARD SYSTEMS; A. STANDARD OPERATION
4 4. INSTALLATION AND SIZING CONSIDERATIONS The Well-X1 ™ functions like a traditional pressure switch by cycling the pump on and off. The factory pressure settings are 40 psi cut-in and 60 psi cut-out. The controller allows these settings to be adjusted to best suit the application. The Well-X1 ™ c...
Page 5 - INSTALLATION CONSIDERATIONS; LOCATION; • Ensure a Tuf Kote; ORIENTATION; may be installed below grade in a well pit or other suitable
5 5. INSTALLATION CONSIDERATIONS LOCATION The Well-X1 ™ is designed for indoor and outdoor installations. The NEMA 3R enclosure can be installed in direct weather. If installed outdoors, be sure the following conditions are met: • Do not install where ambient temperatures can drop below freezing or ...
Page 6 - will allow the Well-X1
6 6. PLUMBING 1. Plumbing connections are similar to a traditional "tank cross" or "tank tee". Provisions are made for popular line sizes via a 1-1/4" NPT male outer thread and a 1" NPT female inner thread. The plumbing connections are not directional and allow flow from eith...
Page 7 - A drip pan connected to an adequate
7 4. Connect the water line from the well pump to the inlet of the Well-X1 ™ . 5. Plumb the outgoing supply to the building's water supply system or into the water treatment equipment (if present). 6. Install a blow down tube from the relief valve to a drain or to within 6" of the floor as requi...
Page 8 - Shut off the circuit breaker for the well system. Loosen; and labeled appropriately.; After completing the wiring, reattach the front cover by
8 7. WIRING LINE LINE MOTOR MOTOR BLACK WHITE/STRIPE BLUE WHITE TAB TAB SCREW 1. Shut off the circuit breaker for the well system. Loosen the top screw housing cover. Flip the cover forward and remove to expose the control wires. Electrocution hazard. For your safety, the information in this manual ...
Page 9 - After plumbing and wiring are complete, close the; by turning on the; After a slight pause, the pump will start and the system; arrow
9 8. STARTUP & ADJUSTMENT 1. After plumbing and wiring are complete, close the service valve to allow startup without pressurizing the entire plumbing system. If a service valve was not installed, close all fixtures in the home. Ensure the bottom drain is closed. 2. Restore power to the Well-X1 ...
Page 10 - Slowly open the service valve to allow the system to; to begin drawing water from
10 8. STARTUP & ADJUSTMENT (con't) 5.The factory cut-out (pump off) setting is 60 psig. When the pump reaches 60 psig, the Well-X1 ™ will shut the pump off. Check the plumbing for leaks and repair before continuing. If during startup the cut-out setting of 60 psig cannot be reached, read the adj...
Page 11 - To enter the programming mode, press and hold the; and; PRESSURE ADJUSTMENT; CUT
11 1. To enter the programming mode, press and hold the MODE button until LO appears. This is the cut-in setting. Factory default will be 40 psi. 2. Use the s and t arrows to raise or lower the cut- in setting. Adjustment can be made within 10 psig or as wide as 55 psig of the cut-out setting to 60 ...
Page 12 - • Do not adjust or add pressure if there has been a loss
12 3. To adjust the cut-out, depress MODE once and the display will read HI. Again, press the t or s buttons to raise or lower the setting. The same 10-55 psig differential range applies. Maximum setting is 80 psig. 4. After adjusting the cut-in and cut-out, release the buttons. After a slight pause...
Page 13 - PUMP PROTECTION AND DIAGNOSTICS; alert the user to a potential problem, prompting service.; ERROR CODES; ERROR CODE; or waterlogged tank. Pump
13 9. PUMP PROTECTION AND DIAGNOSTICS The Well-X1 ™ continually monitors pressure, cycle time and voltage to protect the well pump. The following error codes alert the user to a potential problem, prompting service. E1 : Rapid Cycle E2 : Low Suction (low water cut-off) E3 : Voltage Protection E5 : I...
Page 15 - REPLACEMENT PARTS; DESCRIPTION
15 11. REPLACEMENT PARTS DESCRIPTION POSITION WX1-202 WX1-203 WX1-250 WX1-251 WX1-302 Replacement tank: Blue 1 144R273 146R825 145R379 145R380 150R92 Replacement tank: Tuf Kote™ 1 144R274 146R826 145R381 145R382 150R93 Electronic control (no cover) 2 146R2321 146R2321 146R2321 146R2321 146R2321 Cont...
Page 16 - AMTROL INC. LIMITED PRODUCT WARRANTY
16 AMTROL INC. LIMITED PRODUCT WARRANTY Products covered: all Products manufactured by AMTROL Inc. (“AMTROL”). This warranty cannot be transferred – it is extended only to the original Purchaser or First User of the Product. By accepting and keeping this Product you agree to all of the warranty term...