Amtrol 200-l - Manual

Amtrol 200-l

Amtrol 200-l – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
Page: / 2
Loading the manual

EXTROL

®

L SERIES

REPLACEMENT BLADDER INSTRUCTIONS

PLUG

AIR VALVE

DOME

Figure 1

DRAIN PLUG

STAND

DOME

Figure 2

MARK

Figure 3

DIP

TUBE

Figure 4

READ CAREFULLY THE EXTROL

REPLACEMENT BLADDER INSTRUCTIONS

TO AVOID SERIOUS PERSONAL INJURY AND PROPERTY

HAZARDS AND TO ENSURE SAFE USE AND PROPER CARE

OF THIS PRODUCT.

EXPLOSION OR RUPTURE HAZARD. THE

EXPANSION TANK MUST BE OPERATED SO

THAT THE PRESSURE DOES NOT EXCEED THE MAXIMUM

WORKING PRESSURE.

This Product, like most Products under

pressure, may over time corrode, weaken and

burst or explode, causing serious or fatal injury, leaking or flooding

and/or property damage. To minimize risk, a licensed professional

must install and periodically inspect and service the Product. A drip

pan connected to an adequate drain must be installed if leaking or

flooding could cause property damage. Do not locate in an area

where leaking could cause property damage to the area adjacent to

the appliance or to lower floors of the structure.

Installation

1. Isolate tank from system.
2. Release system pressure from tank.
3. Remove air valve core to bleed remaining air charge

(Figure 1).

4. Remove drain plug (Figure 2).
5. Disconnect system connection.
6. Mark mating flanges in order to match when re-assembling

(Figure 3).

7. Remove bolted upper flange and dip tube/hose.

8. Attached to the upper flange is the bladder support and

dip tube/hose (Figure 4). Replace the dip tube/hose with

the new one provided in package.

9. Using a pump, remove any remaining water inside of

bladder.

10.Using a chain block, lift bladder out of the tank with a

twisting motion.

NOTE:

Inspect for shipping damage and notify freight carrier or store where purchased immediately if damage is present. To avoid risk of personal

injury and property damage, if the product appears to be malfunctioning or shows signs of corrosion, call a qualified professional immediately. Current

copies of the Product manual can be viewed at www.amtrol.com. Use proper safety equipment when installing.

THIS IS THE SAFETY ALERT SYMBOL. IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL INJURY AND OTHER

HAZARDS. OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO REDUCE THE RISK OF PERSONAL

INJURY AS WELL AS PROPERTY DAMAGE.

SYSTEM

CONNECTION

DIP TUBE/FLANGE ASSEMBLY

DRAIN

PLUG/

COUPLING

AIR

VALVE

DIP

TUBE/

HOSE

OLD

BLADDER

Models 200-L through 15000-L

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Amtrol Models