Amtrol RP-25HP - Manual

Amtrol RP-25HP

This Installation Manual covers the AMTROL Pressuriser Water Pressure Booster System with Guardian CP™ Control, focusing on safety protocols, system compatibility, and proper setup for models like RP-10HP, RP-15HP, and RP-25HP. The guide emphasizes critical aspects such as water system integration, pressure relief valve requirements, and handling precautions–including warnings about chlorine or aggressive chemicals–to ensure safe operation and prevent damage. It also includes detailed electrical safety guidelines, pump compatibility checks, and sizing specifications for installation, ensuring proper functionality and reliability in residential or commercial applications.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4

Table of Contents:

  • Page 1 – Installation and Operation for Pressuriser Systems
  • Page 2 – System Installation Specifications and Sizing
  • Page 3 – Guardian CP™ Programming, Maintenance, and Start-up
  • Page 4 – Troubleshooting and Error Codes
Loading the manual
Page 1

USE ONLY WITH POTABLE WATER SYSTEMS.

Do not operate in a setting with freezing

temperatures or where the temperature can exceed 200°F and do not

exceed the maximum working pressure specified for this Product.

READ CAREFULLY THE PRODUCT

INSTALLATION & OPERATION INSTRUCTIONS.

FAILURE TO FOLLOW THE INSTRUCTIONS AND WARNINGS MAY

RESULT IN SERIOUS OR FATAL INJURY AND/OR PROPERTY

DAMAGE, AND WILL VOID THE PRODUCT WARRANTY. THIS

PRODUCT MUST BE INSTALLED BY A QUALIFIED PROFESSIONAL.

FOLLOW ALL APPLICABLE LOCAL AND STATE CODES AND

REGULATIONS. IN THE ABSENCE OF SUCH CODES, FOLLOW THE

CURRENT EDITIONS OF THE NATIONAL PLUMBING CODE AND

NATIONAL ELECTRIC CODE, AS APPLICABLE.

This Product, like most Products under pressure,

may over time corrode, weaken and burst or

explode, causing serious or fatal injury, leaking or flooding and/or

property damage. To minimize risk, a licensed professional must install

and periodically inspect and service the Product. A drip pan connected to

an adequate drain must be installed if leaking or flooding could cause

property damage. Do not locate in an area where leaking could cause

property damage to the area adjacent to the appliance or to lower floors

of the structure.

CALIFORNIA PROPOSITION 65 WARNING!

This product contains a

chemical known by the State of California to cause cancer and to cause

birth defects or other reproductive harm. (California Installer/Contractor

- California law requires that this notice be given to consumer/end user

of this product.)

For more information: www.amtrol.com/prop65.html

RUPTURE OR EXPLOSION HAZARD.

Do not

expose Product to freezing temperatures or

temperatures in excess of 200°F. Do not adjust the pre-charge or

re-pressure this Product except during installation or regular inspection.

Replace the Product and do not adjust the precharge if corroded,

damaged or with diminished integrity. Adjustments to pre-charge must be

done at ambient temperature only. Failure to properly size the Product or

follow these instructions may result in excessive strain on the system and

may lead to Product failure, serious or fatal personal injury, leakage and/

or property damage.

A relief valve must be installed to prevent pressure

in excess of local code requirement or maximum

working pressure designated in the Product Manual, whichever is less.

At least once every 3 years or if discharge is present, a licensed

contractor should inspect the temperature and pressure relief valve and

replace if corrosion is evident or the valve does not function.

FAILURE

TO INSPECT THIS VALVE AS DIRECTED COULD RESULT IN

UNSAFE TEMPERATURE OR PRESSURE BUILD-UP WHICH CAN

RESULT IN PRODUCT FAILURE, SERIOUS INJURY OR DEATH AND/

OR SEVERE PROPERTY DAMAGE AND VOID THE PRODUCT

WARRANTY.

Chlorine & Aggressive Water:

The water quality

can significantly influence the life of this Product.

You should test for corrosive elements, acidity, total solids and other

relevant contaminants, including chlorine and treat your water appropriately

to insure satisfactory performance and prevent premature failure.

AMTROL PRESSURISER

®

WATER PRESSURE BOOSTER SYSTEM

WITH GUARDIAN CP

CONTROL

INSTALLATION & OPERATION INSTRUCTIONS

NOTE:

Inspect for shipping damage. Notify freight carrier or store where purchased immediately if damage is present. To avoid risk of personal injury

and property damage, if the product appears to be malfunctioning or shows signs of corrosion, call a qualified professional immediately. Current copies

of the product manual can be viewed at www.amtrol.com. Use proper safety equipment when installing.

THIS IS THE SAFETY ALERT SYMBOL. IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL INJURY AND OTHER

HAZARDS. OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO REDUCE THE RISK OF PERSONAL

INJURY AS WELL AS PROPERTY DAMAGE.

Models RP-10HP, RP-15HP and RP-25HP

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
Amtrol
Model
RP-25HP
Document type
Manual
Language(s)
English
Pages
4
File size
950.4 KB
Format
PDF

Summary

Page 1 - Installation and Operation for Pressuriser Systems

Installation and operation instructions for AMTROL Pressuriser Water Pressure Booster Systems, including safety warnings regarding water system compatibility, temperature limits, and handling aggressive water.

Page 2 - System Installation Specifications and Sizing

Safety warnings, installation procedures, electrical safety, pump compatibility, required piping, and sizing specifications with diagrams for different pump models.

Page 3 - Guardian CP™ Programming, Maintenance, and Start-up

Instructions for programming, operation, start-up, maintenance guidelines, winterizing procedures, differential pressure settings, and basic wiring diagrams for the pump unit.

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.